Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Low-noise co-arm differential sensor for an optical frequency comb sampling an E-field test system

Not Accessible

Your library or personal account may give you access

Abstract

Optical frequency comb (OFC) technology can realize the rapid measurement of electric fields (E-fields) with large bandwidth. However, this technology suffers from the problem of high intensity noise, resulting in low sensitivity and a blind frequency region. In order to solve the above problems, a dual-path optical E-field sensor with a common reference arm based on a lithium niobate optical waveguide is proposed. The introduction of the reference arm improves the balance of optical paths and the degree of integration. A segmented electrode is also designed to ensure the generation of reverse electrical signals on two Mach–Zehnder interferometers (MZIs). After exiting from the differential photodetector (PD), the intensity noise can be removed, and the sensitivity of the sensor can be improved. After testing, the maximum intensity noise reduction is about 37 dB, the average noise reduction is about 22.3 dB, and the blind frequency region can be eliminated with the co-arm differential optical E-field (CDOE) sensor in the process of measuring the signal. This sensor can be used in the 1 MHz–12 GHz bandwidth with a sensitivity better than 10 mV/m·√Hz.

© 2024 Optica Publishing Group

Full Article  |  PDF Article
More Like This
Stabilizing Fabry–Perot optical frequency comb with differential phase detection and bias compensation

Xiyi Weng, Wei Wei, Weilin Xie, and Yi Dong
Opt. Lett. 49(5) 1113-1116 (2024)

Broadband, high-power optical frequency combs covering visible to near-infrared spectral range

Haochen Tian, Ruichen Zhu, Runmin Li, Sida Xing, Thomas R. Schibli, and Kaoru Minoshima
Opt. Lett. 49(3) 538-541 (2024)

Two-dimensional angle measurement with sub-arcsecond precision and MHz update rate using heterodyne interferometry with optical frequency comb

Chen Lin, Siyu Zhou, Liheng Shi, Yuetang Yang, and Guanhao Wu
Opt. Lett. 49(3) 526-529 (2024)

Data availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (8)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (6)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.