Abstract

Implantable optical technologies provide measurements of cerebral hemodynamic activity from freely behaving animals without movement constraint or anesthesia. In order to study state-dependent neural evoked responses and the consequential hemodynamic response, we simultaneously measured EEG and scattered light changes in chronically implanted rats. Recordings took place under freely behaving conditions, allowing us to compare the evoked responses across wake, sleep, and anesthetized states. The largest evoked electrical and optical responses occurred during quiet sleep compared to wake and REM sleep, while isoflurane anesthesia showed a large, late burst of electrical activity synchronized to the stimulus but an earlier optical response.

© 2009 Optical Society of America

1. Introduction

Optical imaging of cerebral hemodynamic activity provides an index of neuronal activation and can be used as an indirect probe of neural processing and function. Several investigators have utilized optical brain imaging techniques [1, 2, 3, 4, 5, 6, 7, 8, 9], although animals typically remain anesthetized or restrained throughout the recordings. Alterations in conscious states, however, have profound effects on global cerebral perfusion [10], evoked electrical responses [11, 12], and evoked hemodynamic responses [2, 5]. How these different states affect neurovascular coupling is still not well understood. While some investigators have studied changes in the hemodynamic response between wake and anesthetized conditions [2, 5], the wakelike conditions are confined to restrained animals. In order to probe state-dependent neurovascular coupling, we measured changes in local cerebral perfusion across different states of consciousness under freely behaving conditions.

Sleep research has long postulated that sleep leads to restoration of neural tissue [13]; however, direct causal evidence for this theory remains elusive. Previous sleep studies have shown a decrease in metabolic activity during quiet sleep (QS) compared to wake and an increase in metabolic activity during rapid eye movement (REM) sleep compared to QS ([10]; for a review see [14, 15]). Additionally, evoked electrical response potentials (ERPs) are larger during QS than wake [11, 12], and evoked optical signals are larger in amplitude under wake conditions than anesthetized conditions [2, 5]. Other optical studies in humans show slow (of the order of minutes) net increases in oxygenated hemoglobin and deoxygenated hemoglobin during wakeful stimulation and net decreases during sleep stimulation [16].

In order to systematically investigate evoked cerebral hemodynamic responses during different conscious states, we measured the evoked electrical response along with the evoked optical response of 660nm light reflected from the rat auditory cortex following auditory stimulation during wake and sleep of freely behaving animals and during isoflurane anesthesia.

2. Methods

2A. Hardware

We measured reflected light changes from the rat auditory cortex using an implanted 1mm silicon photodiode [Fig. 1(A), PC1-6, Pacific Silicon Sensors, Westlake Village, California, USA] and a 660nm light emitting diode [LED, Fig. 1(B), 1.6mW, B5b-436-30, Roithner Lasertechnik, GmbH, Vienna, Austria]. We chose 660nm light because LEDs at this wavelength provided the brightest illumination, which is necessary in order to collect a sufficient number of photons to extract the hemodynamic response with sufficient signal-to-noise ratio. To reduce the LED size while maintaining high intensity output, we thinned the plastic casing of the LED to a width of 1mm. A small drop of epoxy on the end of the LED acted as a lens to focus the light onto the cortex. The photodiode collected multiply scattered light from the cortex. To maximize light collection efficiency, we coupled the photodiode to a 1mm thick plastic optical fiber encased in stainless steel hypodermic tubing that was in direct contact with the tissue [Fig. 1(A)]. Other methods form an optical window over the cortex and use lens coupled imaging devices. By placing the optical fiber in contact with the tissue, we reduced photon loss within the free space between the dura and the photodiode. The fiber was cut to 8mm in length and polished prior to implantation.

2B. Implantation

During initial surgical procedures, female Sprague–Dawley rats (250300g, Simonsen Laboratories, Gilroy, California, USA, n=4) were anesthetized using isoflurane gas mixed with pure oxygen. We delivered 5.0% isoflurane for the initial induction and then reduced the concentration (2.3%–2.9%) for the remaining surgical procedure. The anesthesia depth was monitored via the toe pinch reflex, electrocardiogram (EKG), and respiration. All procedures were approved by the Washington State University Animal Care and Use Committee (IACUC). The body temperature was maintained at 37°C (±0.5°C) using a heating pad and rectal thermometer probe, and the heart rate and respiration rate were continuously monitored using subcutaneous pin electrodes. After shaving the rat’s scalp and fixing the head in a stereotaxic frame, we made an incision down the midline exposing the skull. We retracted the skin, removed the fascia, and detached the temporalis muscle from the skull in order to expose the area over the auditory cortex. Eight 0.9mm diameter holes were drilled around the skull using a dental drill, and blunted stainless steel screws were inset making contact with the cortex without applying pressure or puncturing the dura. One frontal screw and one parietal screw measured the EEG, one occipital screw served as a ground reference [Fig. 1(C), filled circles], and the remaining screws secured the headstage in place [Fig. 1(C), open circles]. A 1.4mm hole was drilled approximately 3mm caudal to bregma, over the thinned temporal ridge, for insertion of the photodiode, and another 1.4mm hole was drilled approximately 3mm caudal to the photodiode for insertion of the LED. Two insulated stainless steel wires with 1mm exposed wire ends were placed in the thoracic cavity and neck muscles to measure the heart rate (EKG) and muscle activity (EMG), respectively. A miniature plug connected wires from the LED, photodiode, and recording electrodes, and all the components were secured using dental cement. Flunixin (1.1mg/kg) was delivered subcutaneously, and a liberal amount of antibiotic ointment was applied to the base of the headstage each day for 3 days following the recovery. Rats were allowed a 2 week recovery period before recording.

2C. Recordings

For freely moving conditions, rats were placed in a 26.5cm×26.5cm×34cm acrylic chamber and tethered using a 55cm long cable and swivel commutator. Signals were amplified, (AC photodiode x200, DC photodiode x1, EEG x1000, EKG x1000, EMG x1000), filtered from 0.1Hz to 3.2kHz, and digitized at 10kHz using custom-built hardware [17]. To reduce noise in the recordings, the frontal EEG screw electrode was grounded.

In order to generate a substantial hemodynamic response, we stimulated the cortex through a 10Hz burst of five speaker clicks (64dB) delivered at random intervals between 2 and 13 s throughout the recording. Although we recorded from a large area of cortex, we provided a relatively specific stimulus and therefore assume that the evoked electrical and optical responses were primarily due to auditory stimulation, despite volume conduction [18]. Rats were recorded under freely moving conditions, during wake and sleep states, with food and water available ad libitum. In order to achieve adequate sleep, we recorded rats for 24 consecutive hours. Wake/sleep states were sorted into 2 s epochs and scored based on EEG delta power (03Hz) and EMG activity. Wake characteristics included high frequency, low amplitude EEG signals along with large amplitude, variable EMG signals. QS states showed low frequency, high amplitude EEG signals along with a constant moderate amplitude EMG from sustained muscle tone. REM sleep exhibited high frequency, low amplitude EEG, similar to wake, with a nearly flat EMG due to muscle atonia [19]. Two 24 h recordings were averaged together in order to improve signal-to-noise in the optical signal. An anesthetized state was achieved using a mask to deliver isoflurane gas mixed with oxygen at high concentrations (5.0%) for initial induction. The concentration of isoflurane was then reduced to 2.0% before experimentation to maintain a deep anesthetic plane and was monitored by muscle relaxation, respiratory rate, evoked electrical responses, and burst suppression ratio. The burst suppression ratio, defined as the sum of the silent periods over the total epoch time, was 0.74±0.05. We averaged together 500 stimuli and then allowed the rat one week to recover before the next recording.

All the data were analyzed using Octave, an open source data analysis package (www.octave.org). The evoked electrical and optical responses were sorted by state and averaged together across stimuli. The evoked electrical response was recorded from the parietal screw electrode, closest to the auditory cortex. The amplitude of the evoked ERP was reported as the amplitude difference between the first peak (P1) and first trough (N1) components of the first ERP.

The hemodynamic response was measured in terms of changes in 660nm light. Light entered the cortex and was multiply scattered before being detected by the photodiode. Due to the relatively high number of photons absorbed by hemoglobin at this wavelength, we assume that our signal is predominantly affected by changes in absorption rather than scattering [20]. Additionally, according to the hemoglobin absorption curve, deoxygenated hemoglobin absorbs ten times more 660nm light than oxygenated hemoglobin. However, changes in oxyhemoglobin and deoxyhemoglobin concentrations are coupled with changes in blood volume and flow. Figure 2 shows the sensitivity of the optical signal to changes in tissue oxygen saturation (top) and to changes in blood volume (bottom) for varying initial oxygen saturation conditions. As the blood becomes more oxygenated, the optical response is more sensitive to changes in deoxygenated hemoglobin and less sensitive to changes in blood volume. A detailed anal ysis is given in the Appendix. Bulk brain tissue oxygen saturation is lower than arterial oxygen saturation; thus, we expect that our optical signal will be affected by a combination of changes in deoxyhemoglobin concentration and blood volume. Since we are limited to one wavelength, the deoxyhemoglobin and blood volume components cannot be separated, and additional studies are needed using at least two wavelengths.

To assess evoked changes in the hemodynamics due to neural activation, the AC optical signal was divided by the DC optical signal reporting fractional changes (dI/I) and then inverted so that an increase in signal corresponded to an increase in blood volume/deoxyhemoglobin. The signal peak was defined as the first local maximum following stim ulation and the trough was defined as the local minimum following the peak. The peak and trough amplitude were measured in reference to baseline activity. In order to average across multiple recordings, the optical responses during wake, QS, and REM were normalized to the QS peak. We chose QS because responses were most consistent in this state. Since the isoflurane recordings took place at a different time, these data were not normalized. Evoked electrical and optical response amplitudes and times were measured for four animals, and the mean and standard error were calculated. Statistical significance was calculated using a Mann–Whitney test. In order to test the state dependence of the neurovascular response, we plotted the ERP amplitude (P-N1) versus the optical response amplitude (peak–trough) for each individual recording.

3. Results

Figure 3 shows a sample of the ERPs across state from one rat. Under all conditions, the ERP was largest for the first stimulus and subsequent ERPs corresponding to subsequent stimuli were smaller. As previously reported, ERPs during QS were significantly larger in amplitude compared to wake. REM sleep ERPs were similar in size and shape to the ERPs during wakefulness [12]. Under isoflurane anesthesia, a small evoked response appeared after the first stimulus, followed by a large, elongated, and late peak due to averaged burst activity synchronized to the stimulus. The average of the bursts forms a response that appears similar to a large and late evoked response, but the underlying mechanisms that generate the burst are different [11]. An example of synchronized individual bursts and the burst average are shown in the lower inset of Fig. 3.

Typical evoked optical responses from one rat across all states are shown in Fig. 4. While some initial fast optical components may have been present, we did not collect a sufficient number of trials to resolve the fast signal [21]. This study focused on two components from the slower hemodynamic response. During wake, the optical signal showed an initial peak that occurred around 1.8s, followed by a successive trough at 3.3s. During QS, there was a large increase in dI/I at 2.3s and a decrease at 4.1s. During this state, the signal was phase shifted where the peak and trough appeared later compared to the other states. REM sleep exhibited a peak at 1.5s followed by a trough at 3.3s. Under isoflurane anesthesia, the evoked optical signal had an initial increase at 1.6s and a subsequent decrease at 3.2s.

Evoked optical responses across states for four animals are shown in Fig. 5. The wake/sleep amplitudes were normalized to the QS peak for each rat. Note that the optical amplitude scaling was twice as large during QS [Fig. 5(B)] than during wake [Fig. 5(A)] and REM [Fig. 5(C)]. Since the isoflurane recordings took place on a different day than the wake/sleep recordings, the trace amplitudes were presented as changes from baseline conditions and the amplitudes are based on a different scale. The peaks and troughs in the responses were marked with arrows. The traces show similar trends in peak and trough amplitudes and times during each state along with the variability between animals.

We compared the ERP amplitude, measured as the difference between P1 and N1 and normalized to QS, across states (Table 1). The ERP amplitude was significantly larger during QS than wake, REM, and isoflurane (p<0.05). As expected, the ERP amplitude did not differ between wake and REM.

We compared the optical response peaks and troughs across states by plotting the amplitude and time for each animal [Fig. 6(A)]. The mean amplitude and time from the four rats were plotted for each state along with the vertical and horizontal error bars, respectively. The peak amplitude was significantly larger (p<0.05) during QS than wake or REM; however, the trough amplitude did not significantly differ (data points circled in Fig. 6, mean and standard error values shown in Table 1). Both the optical peak and trough during QS occurred later in time than during isoflurane (p<0.05).

In order to illustrate the relationship between the ERP response and the optical response, we plotted the optical amplitude (peak–trough) versus the ERP amplitude (P1-N1) across each state [Fig. 6(B)]. During wake, both the ERP and the optical amplitude were small compared to QS. During REM, there was a larger range of ERP and optical amplitudes but, on average, lower response amplitudes compared to QS. The ERP amplitude during QS was similar to the burst amplitude during isoflurane anesthesia. Additionally, the optical responses were similar in amplitude.

4. Discussion

Optical studies under freely behaving conditions allowed us to probe the processes involved in neurovascular coupling under wake, sleep, and anesthetized states. The ERP signals during REM sleep were nearly identical to those during wakefulness. While the averaged evoked optical responses were similar in time and amplitude, the individual optical responses experienced high variability in the signal, as evident by a lower signal-to-noise ratio compared to QS. Under wakefulness, a movement artifact may have contributed to the noise in the signal. The large, late trough in rat 4 may be residue of a strong movement artifact. During REM sleep, however, movement artifacts do not contribute since animals experience muscle atonia, a characteristic of REM sleep. In rat 3, it was difficult to distinguish between deep QS and REM. As a result, the peak and trough in the REM optical response may have shifted later in time, having a time course similar to QS.

The ERP signal during QS exhibited a significant amplitude increase compared to the wake and REM states. The optical peak amplitude was significantly larger during QS, yet the trough amplitude did not significantly differ. The larger hemodynamic response during QS may be due to a lower initial blood perfusion baseline and a larger fractional change. During wake and REM there may be a larger degree of ongoing neuronal activity and a concomitant larger blood perfusion baseline, resulting in a smaller fractional change. Additionally, since blood flow decreases during QS ([10], for review see [14, 15]), the larger amplitude hemodynamic response during QS may result from blood vessels initially being in a less dilated state, with greater ability to dilate in response to neural activation, resulting in a larger vessel cross-sectional area change. During wake, however, blood vessels may be in a semi-dilated state because they are continually providing metabolites to waking tissue with higher ongoing activity levels and may undergo a smaller change in diameter due to saturation effects. Alternatively, larger ERPs during QS may result from increased synchronous neural activity recruiting more cells and exhibit a greater need for metabolites. As a result, there may be a larger recruitment of blood or increased deoxyhemoglobin concentration within the activated area during QS compared to wake and REM. These conclusions require additional experiments with multiple wavelengths to further investigate the nature of these hemodynamic changes.

Anesthetics alter the state of cortical cells through enhanced inhibition, potentially affecting neurovascular coupling. Isoflurane anesthesia showed a small initial evoked response along with a late synchronization of electrical burst activity that was larger on average than the waking response [11] but elicited a significantly earlier evoked hemodynamic response. The hemodynamic response may result from a convolution of the ERP and burst responses, which could not be dissected in the present study. The earlier phase shift in the optical signals seen under isoflurane anesthesia may result from a suppression of neurovascular control, or decreased latency in the overall neural response since the ERP also appeared earlier (see Fig. 3). Further studies to relate the electrical activity and the optical response are needed to investigate the effects of different anesthetic agents on neurovascular coupling.

A similar hemodynamic response was reported by Chen-Bee et al., where a peak in the inverted optical response occurred around 1s and a trough occurred around 4s while the animal was anesthetized with Nembutal and atropine [7]. These studies, however, were conducted using a whisker twitching stimulus paradigm, and the optical measurements used 635nm light. Regardless of these different recording protocols, the similarities between the optical responses reported here under isoflurane anesthesia are striking. However, our sleep and waking responses show a significantly different amplitude and timing that demonstrate behavioral state modu lation of neurovascular coupling.

Since most optical studies are performed under a variety of different anesthetics and since alterations in the conscious state drastically affect the optical recordings, hemodynamic response models must address the behavioral state of the tissue under investigation. Different anesthetics may alter the neurovascular coupling as evident from the data presented here and elsewhere [2, 5, 7]. If the changes in blood perfusion were directly proportional to electrical activity, we would expect a linear increase in the hemodynamic response under QS. However, since the increase in the hemodynamic response under QS was not only larger in amplitude but also phase shifted later in time, a nonlinear effect on neurovascular coupling is evident. Furthermore, the relationship between the two responses appears to differ depending on the state of the tissue. Studies with different stimulus intensities to investigate the coupling changes between the electrical and the optical response are required. Investigation of the optical response during state transitions can further probe changes in state-dependent coupling.

Appendix

Neural activation elicits changes in local oxygenated hemoglobin concentrations and blood volume. These changes can be measured using optical techniques that rely on the absorption properties of blood [22]. For short distances we can assume that scattering is negligible and attenuation of light through a medium can be described by the Beer–Lambert law:

I=I010μλd,
where μλ is the absorption coefficient and d is the path length of light. Considering only the oxyhemoglobin and deoxyhemoglobin components, the absorption coefficient can be written as a linear combination of the oxyhemoglobin and deoxyhemoglobin absorption extinction coefficients, ελ, and the total hemoglobin concentration, c:
μλ=ελHbO2c+ελHbc.
Changes in absorption are described as
A=log(I0I),
A=SελHbO2cd+(1S)ελHbcd,
where S is the fractional oxygenated hemoglobin saturation. The sensitivity of absorption changes to oxygenated hemoglobin saturation can be calculated as
dAλdS=ελHbO2cdελHbcd.
We solved for the total hemoglobin concentration and path length using Eq. (A4):
cd=A(SελHbO2+(1S)ελHb).
The sensitivity of absorption to changes in oxygenated hemoglobin saturation as a function of wavelength is
dAλdS=A(ελHbO2ελHb)(SελHbO2+(1S)ελHb),
where A=0.7404 for the example shown in Fig. 4. This sensitivity curve is shown in the top trace of Fig. 2 for varying the initial oxygenated hemoglobin saturation conditions. At 660nm wavelength, the optical signal becomes more sensitive to changes in deoxygenated hemoglobin at larger fractional oxygenated hemoglobin saturation.

In order to account for changes in blood volume, the absorption coefficient can be written as

μλ=(1V)μtissue+V(SελHbO2c+(1S)ελHbc),
where V is the fractional blood volume to total volume and μtissue is the absorption coefficient of the tissue. The sensitivity of absorption to changes in blood volume can be written as
dAλdV=μtissued+SελHbO2cd+(1S)ελHbcd,
and the path length is
d=A[1(1V)μtissue+VSελHbO2c+V(1S)ελHbc].
The sensitivity of absorption to changes in blood volume becomes
dAλdV=A(μtissue+SελHbO2c+(1S)ελHbc)(1V)μtissue+VSελHbO2c+V(1S)ελHbc,
where A=0.7404 for the example rat in Fig. 4, μtissue=2.63cm1 [23], V=5.2% [24], and c=5.36E-3moles/L [25]. We assumed that we are predominantly collecting photons traveling through gray matter, the optical properties of gray matter are similar between human tissue and rat tissue, and the hemoglobin concentration is similar to that of whole blood. A plot of the absorption sensitivity to changes in blood volume as a function of wavelength is shown in the bottom trace of Fig. 2, varying the initial oxygenated hemoglobin saturation. At 660nm, the higher the fractional oxygenated hemoglobin saturation, the less sensitive the signal is to changes in blood volume.

This work was supported by the National Institutes of Health (NIH) NIH MH60263 and a grant from the Keck Foundation. J. L. Schei is supported by a fellowship from the Poncin Foundation.

Tables Icon

Table 1. Mean and Standard Error Values of the Electrical and Optical Responses from Four Animalsa

 

Fig. 1 A 1mm diameter photodiode (A) was coupled to a 1mm optical fiber encased in hypodermic tubing and covered with black epoxy. The distal end of the optical fiber was cut to 8mm length, polished, and placed directly in contact with the cortical tissue to collect light from the cortex. To illuminate the tissue with 660nm light, a LED (B) was cut down to a 1mm width and covered with black epoxy. Rats (C) were implanted with a LED and photodiode pair that was placed over the right temporal ridge (T) and 3mm caudal to bregma (B) with 3mm between the LED and the photodiode. To assess behavioral state, EEG screw electrodes were implanted in the frontal and parietal lobes and a ground reference screw was placed in the occipital lobe (solid circles). Five additional screws served as anchors for the headstage (open circles). Neck EMG and EKG wires recorded muscle activity and heart rate.

Download Full Size | PPT Slide | PDF

 

Fig. 2 Top trace, sensitivity of the optical signal to oxyhemoglobin changes as a function of wavelength, described by Eq. (A7), for varying initial oxygenated hemoglobin saturation conditions. At 660nm, the optical signal is more sensitive to changes in deoxyhemoglobin with higher oxyhemoglobin saturation. The lower trace shows the sensitivity of the optical signal to changes in blood volume for varying initial oxygenated hemoglobin saturation conditions. At 660nm, the optical signal is less sensitive to changes in blood volume with higher oxyhemoglobin saturation, described by Eq. (A11). An inset of the hemoglobin absorption curve is shown with a line drawn at 660nm.

Download Full Size | PPT Slide | PDF

 

Fig. 3 Sample evoked electrical responses from one animal for wake, sleep, and anesthetized states were averaged across stimuli and plotted across time. The vertical lines represent each stimulus in the burst. The ERP amplitude, measured from the first peak (P1) to the first trough (N1), was significantly larger during QS than during wake. During REM sleep, the ERP was similar in amplitude to the ERP during wake. Under isoflurane anesthesia, a small amplitude ERP appeared after the first stimulus followed by a late burst of activity synchronized to the stimulus. The lower inset panel demonstrates electrical recordings from a different rat using single click stimuli. The top trace shows several burst events that synchronize to the stimulus and are stacked on top of each other. The bottom trace shows the corresponding average of the bursts, which appears very similar to a late ERP but is unrelated to mechanisms that underlie the ERP [11]. The dotted line indicates the time of the stimulus.

Download Full Size | PPT Slide | PDF

 

Fig. 4 Inverted evoked optical responses were averaged across wake, sleep, and anesthetized states and plotted across time in this example from one rat. The vertical lines represent each stimulus in the burst. To compare sleep state related responses, the wake, QS, and REM traces were normalized to the QS peak while the isoflurane trace was reported as fractional change from baseline, prestimulus conditions. An increase in the inverted signal corresponded to an increase in 660nm light absorption (a decrease in reflected light) and an increase in deoxyhemoglobin/blood volume. The peak amplitude was larger during QS than wake and REM, but the trough amplitude did not significantly differ. Both the peak and the trough were shifted later in time during QS than wake, REM, and isoflurane.

Download Full Size | PPT Slide | PDF

 

Fig. 5 Optical response traces from four animals for (A) wake, (B) QS, (C) REM, and (D) isoflurane. The peaks and troughs, marked by arrows, show the amplitude and timing trends. The variability between rats may be caused by different amounts of movement artifact and/or placement differences. During wake, rat 4 showed a large, late trough that may have been influenced by a movement artifact. Rat 3 showed thicker traces in QS and REM, as well as rat 4 during isoflurane due to decreased signal-to-noise in these recordings.

Download Full Size | PPT Slide | PDF

 

Fig. 6 Peak amplitude versus time plotted for all four animals across states (A). The wake/sleep responses were normalized to the QS peak while the isoflurane response was reported as changes from baseline. The mean peak amplitudes and times are plotted with vertical and horizontal standard error bars, respectively. During QS, the peak amplitude was significantly larger compared to wake and REM. The QS peak was shifted significantly later in time compared to isoflurane. The trough amplitude versus time are plotted for all four animals across states along with the mean and standard error (circled region). Unlike the peak, the QS trough amplitude did not significantly differ between wake and REM, but it occurred significantly later in time compared to isoflurane. A plot of the optical amplitude (peak–trough) versus the ERP amplitude (P1-N1) for individual recordings is shown in B. Wake states exhibited lower amplitude ERP and optical responses while QS states exhibited larger ERP and optical amplitudes. Evoked responses during REM were similar in amplitude to wake responses, but experienced larger variations between animals. During isoflurane, the optical response was similar in amplitude to QS, and the synchronized burst amplitudes were similar to QS ERP amplitudes.

Download Full Size | PPT Slide | PDF

1. J. Mayhew, Y. Zheng, Y. Hou, B. Vuksanovic, J. Verwick, S. Askew, and P. Coffey, “Spectroscopic analysis of changes in remitted illumination: the response to increase neural activity in brain,” NeuroImage 10, 304–326 (1999). [CrossRef]   [PubMed]  

2. J. Berwick, C. Martin, J. Martindale, M. Jones, D. Johnston, Y. Zheng, P. Redgrave, and J. Mayhew, “Hemodynamic response in the unanesthetized rat: intrinsic optical imaging and spectroscopy of the barrel cortex,” J. Cereb. Blood Flow Metab. 22, 670–679 (2002). [CrossRef]   [PubMed]  

3. A. Devor, A. K. Dunn, M. L. Andermann, I. Ulbert, D. A. Boas, and A. M. Dale, “Coupling of total hemoglobin concentration oxygenation, and neural activity in rat somatosensory cortex,” Neuron 39, 353–359 (2003). [CrossRef]   [PubMed]  

4. S. Sheth, M. Nemoto, M. Guiou, M. Walker, N. Pouratian, and A. W. Toga, “Evaluation of coupling between optical intrinsic signals and neuronal activity in rat somatosensory cortex,” NeuroImage 19, 884–894 (2003). [CrossRef]   [PubMed]  

5. L. M. Chen, R. M. Friedman, and A. W. Roe, “Optical imaging of SI topography in anesthetized and awake squirrel monkeys,” J. Neurosci. 25, 7648–7659 (2005). [CrossRef]   [PubMed]  

6. A. K. Dunn, A. Devor, A. M. Dale, and D. A. Boas, “Spatial extent of oxygen metabolism and hemodynamic changes during functional activation of the rat somatosensory cortex,” NeuroImage 27, 279–290 (2005). [CrossRef]   [PubMed]  

7. C. Chen-Bee, T. Agoncillo, Y. Xiong, and R. Frostig, “The triphasic intrinsic signal: implications for functional imaging,” J. Neurosci. 75, 4572–4586 (2007). [CrossRef]  

8. E. M. C. Hillman, A. Devor, M. B. Bouchard, A. K. Dunn, G. W. Krauss, J. Skoch, B. J. Bacskai, A. M. Dale, and D. A. Boas, “Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation,” NeuroImage 35, 89–104 (2007). [CrossRef]   [PubMed]  

9. M. Jones, I. Devonshire, J. Berwick, C. Martin, P. Redgrave, and J. Mayhew, “Altered neurovascular coupling during information-processing states,” Eur. J. Neurosci. 27, 2758–2772 (2008). [CrossRef]   [PubMed]  

10. A. R. Braun, T. J. Balkin, N. J. Wesensten, R. E. Carson, M. Varga, P. Baldwin, S. Selbie, G. Bleneky, and P. Herscovitch, “Regional cerebral blood flow throughout the sleep-wake cycle: an H2O15 PET study,” Brain 120, 1173–1197 (1997). [CrossRef]   [PubMed]  

11. M. Rojas, J. Navas, and D. Rector, “Evoked response potential markers for anesthetic and behavioral states,” Am. J. Physiol. Regulatory Integrative Comp. Physiol. 291, R189–R196 (2006). [CrossRef]  

12. D. M. Rector, I. A. Topchiy, K. M. Carter, and M. J. Rojas, “Local functional state differences between rat cortical columns,” Brain Res. 1047, 45–55 (2005). [CrossRef]   [PubMed]  

13. J. Krueger and F. Obál, “A neuronal group theory of sleep function,” J. Sleep Res. 2, 63–69 (1993). [CrossRef]   [PubMed]  

14. P. Maquet, “Functional neuroimaging of normal human sleep by positron emission tomography,” J. Sleep Res. 9, 207–231 (2000). [CrossRef]   [PubMed]  

15. G. Zoccoli, A. Walker, P. Lenzi, and C. Franzini, “The cerebral circulation during sleep: regulation mechanisms and functional implications,” Sleep Med, Rev. 6, 443–455 (2002). [CrossRef]  

16. Y. Hoshi and M. Tamura, “Dynamic multichannel near- infrared optical imaging of human brain activity,” J. Appl. Physiol. 75, 1842–1846 (1993). [PubMed]  

17. D. M. Rector and J. S. George, “Continuous image and electrophysiological recording with real time processing and control,” Methods 25, 151–163 (2001). [CrossRef]  

18. W. Penfield and H. H. Jasper, Epilepsy and the Functional Anatomy of the Human Brain (Little, Brown, 1954).

19. D. M. Rector, J. L. Schei, and M. J. Rojas, “Mechanisms underlying state dependent surface-evoked response patterns,” Neurosci. doi: 10.1016/j.neuroscience.2008.11.031.

20. A. Roggan, M. Friebel, K. Dorschel, A. Hahn, and G. Muller, “Optical properties of circulating human blood in the wavelength range 4002500nm,” J. Biomed. Opt. 4(1), 36–46 (1999). [CrossRef]  

21. D. M. Rector, K. M. Carter, P. L. Volegov, and J. S. George, “Spatio-temporal mapping of rat whisker barrels with fast scattered light signals,” NeuroImage 26, 619–627 (2005). [CrossRef]   [PubMed]  

22. R. N. Pittman, “In vivo photometric analysis of hemoglobin,” Ann. Biomed. Eng. 14, 119–137 (1986). [CrossRef]   [PubMed]  

23. W. F. Cheong, S. A. Prahl, and A. J. Welch, “A review of the optical properties of biological tissues,” IEEE J. Quantum Electron. 26, 2166–2185 (1990). [CrossRef]  

24. K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27–47 (1990). [CrossRef]   [PubMed]  

25. S. Prahl, “Tabulated molar extinction coefficient for hemoglobin in water,” Oregon Medical Laser Company, http://omlc.ogi. edu/spectra/hemoglobin/index.html.

References

  • View by:
  • |
  • |
  • |

  1. J. Mayhew, Y. Zheng, Y. Hou, B. Vuksanovic, J. Verwick, S. Askew, and P. Coffey, “Spectroscopic analysis of changes in remitted illumination: the response to increase neural activity in brain,” NeuroImage 10, 304-326 (1999).
    [CrossRef] [PubMed]
  2. J. Berwick, C. Martin, J. Martindale, M. Jones, D. Johnston, Y. Zheng, P. Redgrave, and J. Mayhew, “Hemodynamic response in the unanesthetized rat: intrinsic optical imaging and spectroscopy of the barrel cortex,” J. Cereb. Blood Flow Metab. 22, 670-679 (2002).
    [CrossRef] [PubMed]
  3. A. Devor, A. K. Dunn, M. L. Andermann, I. Ulbert, D. A. Boas, and A. M. Dale, “Coupling of total hemoglobin concentration oxygenation, and neural activity in rat somatosensory cortex,” Neuron 39, 353-359 (2003).
    [CrossRef] [PubMed]
  4. S. Sheth, M. Nemoto, M. Guiou, M. Walker, N. Pouratian, and A. W. Toga, “Evaluation of coupling between optical intrinsic signals and neuronal activity in rat somatosensory cortex,” NeuroImage 19, 884-894 (2003).
    [CrossRef] [PubMed]
  5. L. M. Chen, R. M. Friedman, and A. W. Roe, “Optical imaging of SI topography in anesthetized and awake squirrel monkeys,” J. Neurosci. 25, 7648-7659 (2005).
    [CrossRef] [PubMed]
  6. A. K. Dunn, A. Devor, A. M. Dale, and D. A. Boas, “Spatial extent of oxygen metabolism and hemodynamic changes during functional activation of the rat somatosensory cortex,” NeuroImage 27, 279-290 (2005).
    [CrossRef] [PubMed]
  7. C. Chen-Bee, T. Agoncillo, Y. Xiong, and R. Frostig, “The triphasic intrinsic signal: implications for functional imaging,” J. Neurosci. 75, 4572-4586 (2007).
    [CrossRef]
  8. E. M. C. Hillman, A. Devor, M. B. Bouchard, A. K. Dunn, G. W. Krauss, J. Skoch, B. J. Bacskai, A. M. Dale, and D. A. Boas, “Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation,” NeuroImage 35, 89-104 (2007).
    [CrossRef] [PubMed]
  9. M. Jones, I. Devonshire, J. Berwick, C. Martin, P. Redgrave, and J. Mayhew, “Altered neurovascular coupling during information-processing states,” Eur. J. Neurosci. 27, 2758-2772 (2008).
    [CrossRef] [PubMed]
  10. A. R. Braun, T. J. Balkin, N. J. Wesensten, R. E. Carson, M. Varga, P. Baldwin, S. Selbie, G. Bleneky, and P. Herscovitch, “Regional cerebral blood flow throughout the sleep-wake cycle: an H2O15 PET study,” Brain 120, 1173-1197 (1997).
    [CrossRef] [PubMed]
  11. M. Rojas, J. Navas, and D. Rector, “Evoked response potential markers for anesthetic and behavioral states,” Am. J. Physiol. Regulatory Integrative Comp. Physiol. 291, R189-R196(2006).
    [CrossRef]
  12. D. M. Rector, I. A. Topchiy, K. M. Carter, and M. J. Rojas, “Local functional state differences between rat cortical columns,” Brain Res. 1047, 45-55 (2005).
    [CrossRef] [PubMed]
  13. J. Krueger and F. Obál, “A neuronal group theory of sleep function,” J. Sleep Res. 2, 63-69 (1993).
    [CrossRef] [PubMed]
  14. P. Maquet, “Functional neuroimaging of normal human sleep by positron emission tomography,” J. Sleep Res. 9, 207-231(2000).
    [CrossRef] [PubMed]
  15. G. Zoccoli, A. Walker, P. Lenzi, and C. Franzini, “The cerebral circulation during sleep: regulation mechanisms and functional implications,” Sleep Med, Rev. 6, 443-455 (2002).
    [CrossRef]
  16. Y. Hoshi and M. Tamura, “Dynamic multichannel near-infrared optical imaging of human brain activity,” J. Appl. Physiol. 75, 1842-1846 (1993).
    [PubMed]
  17. D. M. Rector and J. S. George, “Continuous image and electrophysiological recording with real time processing and control,” Methods 25, 151-163 (2001).
    [CrossRef]
  18. W. Penfield and H. H. Jasper, Epilepsy and the Functional Anatomy of the Human Brain (Little, Brown, 1954).
  19. D. M. Rector, J. L. Schei, and M. J. Rojas, “Mechanisms underlying state dependent surface-evoked response patterns,” Neurosci. doi: 10.1016/j.neuroscience.2008.11.031.
  20. A. Roggan, M. Friebel, K. Dorschel, A. Hahn, and G. Muller, “Optical properties of circulating human blood in the wavelength range 400-2500 nm,” J. Biomed. Opt. 4(1), 36-46 (1999).
    [CrossRef]
  21. D. M. Rector, K. M. Carter, P. L. Volegov, and J. S. George, “Spatio-temporal mapping of rat whisker barrels with fast scattered light signals,” NeuroImage 26, 619-627(2005).
    [CrossRef] [PubMed]
  22. R. N. Pittman, “In vivo photometric analysis of hemoglobin,” Ann. Biomed. Eng. 14, 119-137 (1986).
    [CrossRef] [PubMed]
  23. W. F. Cheong, S. A. Prahl, and A. J. Welch, “A review of the optical properties of biological tissues,” IEEE J. Quantum Electron. 26, 2166-2185 (1990).
    [CrossRef]
  24. K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
    [CrossRef] [PubMed]
  25. S. Prahl, “Tabulated molar extinction coefficient for hemoglobin in water,” Oregon Medical Laser Company, http://omlc.ogi.edu/spectra/hemoglobin/index.html.

2008 (1)

M. Jones, I. Devonshire, J. Berwick, C. Martin, P. Redgrave, and J. Mayhew, “Altered neurovascular coupling during information-processing states,” Eur. J. Neurosci. 27, 2758-2772 (2008).
[CrossRef] [PubMed]

2007 (2)

C. Chen-Bee, T. Agoncillo, Y. Xiong, and R. Frostig, “The triphasic intrinsic signal: implications for functional imaging,” J. Neurosci. 75, 4572-4586 (2007).
[CrossRef]

E. M. C. Hillman, A. Devor, M. B. Bouchard, A. K. Dunn, G. W. Krauss, J. Skoch, B. J. Bacskai, A. M. Dale, and D. A. Boas, “Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation,” NeuroImage 35, 89-104 (2007).
[CrossRef] [PubMed]

2006 (1)

M. Rojas, J. Navas, and D. Rector, “Evoked response potential markers for anesthetic and behavioral states,” Am. J. Physiol. Regulatory Integrative Comp. Physiol. 291, R189-R196(2006).
[CrossRef]

2005 (4)

D. M. Rector, I. A. Topchiy, K. M. Carter, and M. J. Rojas, “Local functional state differences between rat cortical columns,” Brain Res. 1047, 45-55 (2005).
[CrossRef] [PubMed]

L. M. Chen, R. M. Friedman, and A. W. Roe, “Optical imaging of SI topography in anesthetized and awake squirrel monkeys,” J. Neurosci. 25, 7648-7659 (2005).
[CrossRef] [PubMed]

A. K. Dunn, A. Devor, A. M. Dale, and D. A. Boas, “Spatial extent of oxygen metabolism and hemodynamic changes during functional activation of the rat somatosensory cortex,” NeuroImage 27, 279-290 (2005).
[CrossRef] [PubMed]

D. M. Rector, K. M. Carter, P. L. Volegov, and J. S. George, “Spatio-temporal mapping of rat whisker barrels with fast scattered light signals,” NeuroImage 26, 619-627(2005).
[CrossRef] [PubMed]

2003 (2)

A. Devor, A. K. Dunn, M. L. Andermann, I. Ulbert, D. A. Boas, and A. M. Dale, “Coupling of total hemoglobin concentration oxygenation, and neural activity in rat somatosensory cortex,” Neuron 39, 353-359 (2003).
[CrossRef] [PubMed]

S. Sheth, M. Nemoto, M. Guiou, M. Walker, N. Pouratian, and A. W. Toga, “Evaluation of coupling between optical intrinsic signals and neuronal activity in rat somatosensory cortex,” NeuroImage 19, 884-894 (2003).
[CrossRef] [PubMed]

2002 (2)

J. Berwick, C. Martin, J. Martindale, M. Jones, D. Johnston, Y. Zheng, P. Redgrave, and J. Mayhew, “Hemodynamic response in the unanesthetized rat: intrinsic optical imaging and spectroscopy of the barrel cortex,” J. Cereb. Blood Flow Metab. 22, 670-679 (2002).
[CrossRef] [PubMed]

G. Zoccoli, A. Walker, P. Lenzi, and C. Franzini, “The cerebral circulation during sleep: regulation mechanisms and functional implications,” Sleep Med, Rev. 6, 443-455 (2002).
[CrossRef]

2001 (1)

D. M. Rector and J. S. George, “Continuous image and electrophysiological recording with real time processing and control,” Methods 25, 151-163 (2001).
[CrossRef]

2000 (1)

P. Maquet, “Functional neuroimaging of normal human sleep by positron emission tomography,” J. Sleep Res. 9, 207-231(2000).
[CrossRef] [PubMed]

1999 (2)

A. Roggan, M. Friebel, K. Dorschel, A. Hahn, and G. Muller, “Optical properties of circulating human blood in the wavelength range 400-2500 nm,” J. Biomed. Opt. 4(1), 36-46 (1999).
[CrossRef]

J. Mayhew, Y. Zheng, Y. Hou, B. Vuksanovic, J. Verwick, S. Askew, and P. Coffey, “Spectroscopic analysis of changes in remitted illumination: the response to increase neural activity in brain,” NeuroImage 10, 304-326 (1999).
[CrossRef] [PubMed]

1997 (1)

A. R. Braun, T. J. Balkin, N. J. Wesensten, R. E. Carson, M. Varga, P. Baldwin, S. Selbie, G. Bleneky, and P. Herscovitch, “Regional cerebral blood flow throughout the sleep-wake cycle: an H2O15 PET study,” Brain 120, 1173-1197 (1997).
[CrossRef] [PubMed]

1993 (2)

J. Krueger and F. Obál, “A neuronal group theory of sleep function,” J. Sleep Res. 2, 63-69 (1993).
[CrossRef] [PubMed]

Y. Hoshi and M. Tamura, “Dynamic multichannel near-infrared optical imaging of human brain activity,” J. Appl. Physiol. 75, 1842-1846 (1993).
[PubMed]

1990 (2)

W. F. Cheong, S. A. Prahl, and A. J. Welch, “A review of the optical properties of biological tissues,” IEEE J. Quantum Electron. 26, 2166-2185 (1990).
[CrossRef]

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

1986 (1)

R. N. Pittman, “In vivo photometric analysis of hemoglobin,” Ann. Biomed. Eng. 14, 119-137 (1986).
[CrossRef] [PubMed]

1954 (1)

W. Penfield and H. H. Jasper, Epilepsy and the Functional Anatomy of the Human Brain (Little, Brown, 1954).

Agoncillo, T.

C. Chen-Bee, T. Agoncillo, Y. Xiong, and R. Frostig, “The triphasic intrinsic signal: implications for functional imaging,” J. Neurosci. 75, 4572-4586 (2007).
[CrossRef]

Andermann, M. L.

A. Devor, A. K. Dunn, M. L. Andermann, I. Ulbert, D. A. Boas, and A. M. Dale, “Coupling of total hemoglobin concentration oxygenation, and neural activity in rat somatosensory cortex,” Neuron 39, 353-359 (2003).
[CrossRef] [PubMed]

Askew, S.

J. Mayhew, Y. Zheng, Y. Hou, B. Vuksanovic, J. Verwick, S. Askew, and P. Coffey, “Spectroscopic analysis of changes in remitted illumination: the response to increase neural activity in brain,” NeuroImage 10, 304-326 (1999).
[CrossRef] [PubMed]

Bacskai, B. J.

E. M. C. Hillman, A. Devor, M. B. Bouchard, A. K. Dunn, G. W. Krauss, J. Skoch, B. J. Bacskai, A. M. Dale, and D. A. Boas, “Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation,” NeuroImage 35, 89-104 (2007).
[CrossRef] [PubMed]

Baldwin, P.

A. R. Braun, T. J. Balkin, N. J. Wesensten, R. E. Carson, M. Varga, P. Baldwin, S. Selbie, G. Bleneky, and P. Herscovitch, “Regional cerebral blood flow throughout the sleep-wake cycle: an H2O15 PET study,” Brain 120, 1173-1197 (1997).
[CrossRef] [PubMed]

Balkin, T. J.

A. R. Braun, T. J. Balkin, N. J. Wesensten, R. E. Carson, M. Varga, P. Baldwin, S. Selbie, G. Bleneky, and P. Herscovitch, “Regional cerebral blood flow throughout the sleep-wake cycle: an H2O15 PET study,” Brain 120, 1173-1197 (1997).
[CrossRef] [PubMed]

Beaney, R. P.

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

Berwick, J.

M. Jones, I. Devonshire, J. Berwick, C. Martin, P. Redgrave, and J. Mayhew, “Altered neurovascular coupling during information-processing states,” Eur. J. Neurosci. 27, 2758-2772 (2008).
[CrossRef] [PubMed]

J. Berwick, C. Martin, J. Martindale, M. Jones, D. Johnston, Y. Zheng, P. Redgrave, and J. Mayhew, “Hemodynamic response in the unanesthetized rat: intrinsic optical imaging and spectroscopy of the barrel cortex,” J. Cereb. Blood Flow Metab. 22, 670-679 (2002).
[CrossRef] [PubMed]

Bleneky, G.

A. R. Braun, T. J. Balkin, N. J. Wesensten, R. E. Carson, M. Varga, P. Baldwin, S. Selbie, G. Bleneky, and P. Herscovitch, “Regional cerebral blood flow throughout the sleep-wake cycle: an H2O15 PET study,” Brain 120, 1173-1197 (1997).
[CrossRef] [PubMed]

Boas, D. A.

E. M. C. Hillman, A. Devor, M. B. Bouchard, A. K. Dunn, G. W. Krauss, J. Skoch, B. J. Bacskai, A. M. Dale, and D. A. Boas, “Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation,” NeuroImage 35, 89-104 (2007).
[CrossRef] [PubMed]

A. K. Dunn, A. Devor, A. M. Dale, and D. A. Boas, “Spatial extent of oxygen metabolism and hemodynamic changes during functional activation of the rat somatosensory cortex,” NeuroImage 27, 279-290 (2005).
[CrossRef] [PubMed]

A. Devor, A. K. Dunn, M. L. Andermann, I. Ulbert, D. A. Boas, and A. M. Dale, “Coupling of total hemoglobin concentration oxygenation, and neural activity in rat somatosensory cortex,” Neuron 39, 353-359 (2003).
[CrossRef] [PubMed]

Bouchard, M. B.

E. M. C. Hillman, A. Devor, M. B. Bouchard, A. K. Dunn, G. W. Krauss, J. Skoch, B. J. Bacskai, A. M. Dale, and D. A. Boas, “Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation,” NeuroImage 35, 89-104 (2007).
[CrossRef] [PubMed]

Braun, A. R.

A. R. Braun, T. J. Balkin, N. J. Wesensten, R. E. Carson, M. Varga, P. Baldwin, S. Selbie, G. Bleneky, and P. Herscovitch, “Regional cerebral blood flow throughout the sleep-wake cycle: an H2O15 PET study,” Brain 120, 1173-1197 (1997).
[CrossRef] [PubMed]

Brooks, D. J.

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

Buckingham, P.

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

Carson, R. E.

A. R. Braun, T. J. Balkin, N. J. Wesensten, R. E. Carson, M. Varga, P. Baldwin, S. Selbie, G. Bleneky, and P. Herscovitch, “Regional cerebral blood flow throughout the sleep-wake cycle: an H2O15 PET study,” Brain 120, 1173-1197 (1997).
[CrossRef] [PubMed]

Carter, K. M.

D. M. Rector, I. A. Topchiy, K. M. Carter, and M. J. Rojas, “Local functional state differences between rat cortical columns,” Brain Res. 1047, 45-55 (2005).
[CrossRef] [PubMed]

D. M. Rector, K. M. Carter, P. L. Volegov, and J. S. George, “Spatio-temporal mapping of rat whisker barrels with fast scattered light signals,” NeuroImage 26, 619-627(2005).
[CrossRef] [PubMed]

Chen, L. M.

L. M. Chen, R. M. Friedman, and A. W. Roe, “Optical imaging of SI topography in anesthetized and awake squirrel monkeys,” J. Neurosci. 25, 7648-7659 (2005).
[CrossRef] [PubMed]

Chen-Bee, C.

C. Chen-Bee, T. Agoncillo, Y. Xiong, and R. Frostig, “The triphasic intrinsic signal: implications for functional imaging,” J. Neurosci. 75, 4572-4586 (2007).
[CrossRef]

Cheong, W. F.

W. F. Cheong, S. A. Prahl, and A. J. Welch, “A review of the optical properties of biological tissues,” IEEE J. Quantum Electron. 26, 2166-2185 (1990).
[CrossRef]

Coffey, P.

J. Mayhew, Y. Zheng, Y. Hou, B. Vuksanovic, J. Verwick, S. Askew, and P. Coffey, “Spectroscopic analysis of changes in remitted illumination: the response to increase neural activity in brain,” NeuroImage 10, 304-326 (1999).
[CrossRef] [PubMed]

Dale, A. M.

E. M. C. Hillman, A. Devor, M. B. Bouchard, A. K. Dunn, G. W. Krauss, J. Skoch, B. J. Bacskai, A. M. Dale, and D. A. Boas, “Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation,” NeuroImage 35, 89-104 (2007).
[CrossRef] [PubMed]

A. K. Dunn, A. Devor, A. M. Dale, and D. A. Boas, “Spatial extent of oxygen metabolism and hemodynamic changes during functional activation of the rat somatosensory cortex,” NeuroImage 27, 279-290 (2005).
[CrossRef] [PubMed]

A. Devor, A. K. Dunn, M. L. Andermann, I. Ulbert, D. A. Boas, and A. M. Dale, “Coupling of total hemoglobin concentration oxygenation, and neural activity in rat somatosensory cortex,” Neuron 39, 353-359 (2003).
[CrossRef] [PubMed]

Devonshire, I.

M. Jones, I. Devonshire, J. Berwick, C. Martin, P. Redgrave, and J. Mayhew, “Altered neurovascular coupling during information-processing states,” Eur. J. Neurosci. 27, 2758-2772 (2008).
[CrossRef] [PubMed]

Devor, A.

E. M. C. Hillman, A. Devor, M. B. Bouchard, A. K. Dunn, G. W. Krauss, J. Skoch, B. J. Bacskai, A. M. Dale, and D. A. Boas, “Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation,” NeuroImage 35, 89-104 (2007).
[CrossRef] [PubMed]

A. K. Dunn, A. Devor, A. M. Dale, and D. A. Boas, “Spatial extent of oxygen metabolism and hemodynamic changes during functional activation of the rat somatosensory cortex,” NeuroImage 27, 279-290 (2005).
[CrossRef] [PubMed]

A. Devor, A. K. Dunn, M. L. Andermann, I. Ulbert, D. A. Boas, and A. M. Dale, “Coupling of total hemoglobin concentration oxygenation, and neural activity in rat somatosensory cortex,” Neuron 39, 353-359 (2003).
[CrossRef] [PubMed]

Dorschel, K.

A. Roggan, M. Friebel, K. Dorschel, A. Hahn, and G. Muller, “Optical properties of circulating human blood in the wavelength range 400-2500 nm,” J. Biomed. Opt. 4(1), 36-46 (1999).
[CrossRef]

Dunn, A. K.

E. M. C. Hillman, A. Devor, M. B. Bouchard, A. K. Dunn, G. W. Krauss, J. Skoch, B. J. Bacskai, A. M. Dale, and D. A. Boas, “Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation,” NeuroImage 35, 89-104 (2007).
[CrossRef] [PubMed]

A. K. Dunn, A. Devor, A. M. Dale, and D. A. Boas, “Spatial extent of oxygen metabolism and hemodynamic changes during functional activation of the rat somatosensory cortex,” NeuroImage 27, 279-290 (2005).
[CrossRef] [PubMed]

A. Devor, A. K. Dunn, M. L. Andermann, I. Ulbert, D. A. Boas, and A. M. Dale, “Coupling of total hemoglobin concentration oxygenation, and neural activity in rat somatosensory cortex,” Neuron 39, 353-359 (2003).
[CrossRef] [PubMed]

Frackowiak, R. S. J.

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

Franzini, C.

G. Zoccoli, A. Walker, P. Lenzi, and C. Franzini, “The cerebral circulation during sleep: regulation mechanisms and functional implications,” Sleep Med, Rev. 6, 443-455 (2002).
[CrossRef]

Friebel, M.

A. Roggan, M. Friebel, K. Dorschel, A. Hahn, and G. Muller, “Optical properties of circulating human blood in the wavelength range 400-2500 nm,” J. Biomed. Opt. 4(1), 36-46 (1999).
[CrossRef]

Friedman, R. M.

L. M. Chen, R. M. Friedman, and A. W. Roe, “Optical imaging of SI topography in anesthetized and awake squirrel monkeys,” J. Neurosci. 25, 7648-7659 (2005).
[CrossRef] [PubMed]

Frostig, R.

C. Chen-Bee, T. Agoncillo, Y. Xiong, and R. Frostig, “The triphasic intrinsic signal: implications for functional imaging,” J. Neurosci. 75, 4572-4586 (2007).
[CrossRef]

George, J. S.

D. M. Rector, K. M. Carter, P. L. Volegov, and J. S. George, “Spatio-temporal mapping of rat whisker barrels with fast scattered light signals,” NeuroImage 26, 619-627(2005).
[CrossRef] [PubMed]

D. M. Rector and J. S. George, “Continuous image and electrophysiological recording with real time processing and control,” Methods 25, 151-163 (2001).
[CrossRef]

Gibbs, J. M.

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

Guiou, M.

S. Sheth, M. Nemoto, M. Guiou, M. Walker, N. Pouratian, and A. W. Toga, “Evaluation of coupling between optical intrinsic signals and neuronal activity in rat somatosensory cortex,” NeuroImage 19, 884-894 (2003).
[CrossRef] [PubMed]

Hahn, A.

A. Roggan, M. Friebel, K. Dorschel, A. Hahn, and G. Muller, “Optical properties of circulating human blood in the wavelength range 400-2500 nm,” J. Biomed. Opt. 4(1), 36-46 (1999).
[CrossRef]

Hatazawa, J.

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

Healy, M. J. R.

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

Heather, J. D.

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

Herold, S.

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

Herscovitch, P.

A. R. Braun, T. J. Balkin, N. J. Wesensten, R. E. Carson, M. Varga, P. Baldwin, S. Selbie, G. Bleneky, and P. Herscovitch, “Regional cerebral blood flow throughout the sleep-wake cycle: an H2O15 PET study,” Brain 120, 1173-1197 (1997).
[CrossRef] [PubMed]

Hillman, E. M. C.

E. M. C. Hillman, A. Devor, M. B. Bouchard, A. K. Dunn, G. W. Krauss, J. Skoch, B. J. Bacskai, A. M. Dale, and D. A. Boas, “Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation,” NeuroImage 35, 89-104 (2007).
[CrossRef] [PubMed]

Hoshi, Y.

Y. Hoshi and M. Tamura, “Dynamic multichannel near-infrared optical imaging of human brain activity,” J. Appl. Physiol. 75, 1842-1846 (1993).
[PubMed]

Hou, Y.

J. Mayhew, Y. Zheng, Y. Hou, B. Vuksanovic, J. Verwick, S. Askew, and P. Coffey, “Spectroscopic analysis of changes in remitted illumination: the response to increase neural activity in brain,” NeuroImage 10, 304-326 (1999).
[CrossRef] [PubMed]

Jasper, H. H.

W. Penfield and H. H. Jasper, Epilepsy and the Functional Anatomy of the Human Brain (Little, Brown, 1954).

Johnston, D.

J. Berwick, C. Martin, J. Martindale, M. Jones, D. Johnston, Y. Zheng, P. Redgrave, and J. Mayhew, “Hemodynamic response in the unanesthetized rat: intrinsic optical imaging and spectroscopy of the barrel cortex,” J. Cereb. Blood Flow Metab. 22, 670-679 (2002).
[CrossRef] [PubMed]

Jones, M.

M. Jones, I. Devonshire, J. Berwick, C. Martin, P. Redgrave, and J. Mayhew, “Altered neurovascular coupling during information-processing states,” Eur. J. Neurosci. 27, 2758-2772 (2008).
[CrossRef] [PubMed]

J. Berwick, C. Martin, J. Martindale, M. Jones, D. Johnston, Y. Zheng, P. Redgrave, and J. Mayhew, “Hemodynamic response in the unanesthetized rat: intrinsic optical imaging and spectroscopy of the barrel cortex,” J. Cereb. Blood Flow Metab. 22, 670-679 (2002).
[CrossRef] [PubMed]

Jones, T.

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

Krauss, G. W.

E. M. C. Hillman, A. Devor, M. B. Bouchard, A. K. Dunn, G. W. Krauss, J. Skoch, B. J. Bacskai, A. M. Dale, and D. A. Boas, “Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation,” NeuroImage 35, 89-104 (2007).
[CrossRef] [PubMed]

Krueger, J.

J. Krueger and F. Obál, “A neuronal group theory of sleep function,” J. Sleep Res. 2, 63-69 (1993).
[CrossRef] [PubMed]

Lammertsma, A. A.

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

Leenders, K. L.

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

Lenzi, P.

G. Zoccoli, A. Walker, P. Lenzi, and C. Franzini, “The cerebral circulation during sleep: regulation mechanisms and functional implications,” Sleep Med, Rev. 6, 443-455 (2002).
[CrossRef]

Maquet, P.

P. Maquet, “Functional neuroimaging of normal human sleep by positron emission tomography,” J. Sleep Res. 9, 207-231(2000).
[CrossRef] [PubMed]

Martin, C.

M. Jones, I. Devonshire, J. Berwick, C. Martin, P. Redgrave, and J. Mayhew, “Altered neurovascular coupling during information-processing states,” Eur. J. Neurosci. 27, 2758-2772 (2008).
[CrossRef] [PubMed]

J. Berwick, C. Martin, J. Martindale, M. Jones, D. Johnston, Y. Zheng, P. Redgrave, and J. Mayhew, “Hemodynamic response in the unanesthetized rat: intrinsic optical imaging and spectroscopy of the barrel cortex,” J. Cereb. Blood Flow Metab. 22, 670-679 (2002).
[CrossRef] [PubMed]

Martindale, J.

J. Berwick, C. Martin, J. Martindale, M. Jones, D. Johnston, Y. Zheng, P. Redgrave, and J. Mayhew, “Hemodynamic response in the unanesthetized rat: intrinsic optical imaging and spectroscopy of the barrel cortex,” J. Cereb. Blood Flow Metab. 22, 670-679 (2002).
[CrossRef] [PubMed]

Mayhew, J.

M. Jones, I. Devonshire, J. Berwick, C. Martin, P. Redgrave, and J. Mayhew, “Altered neurovascular coupling during information-processing states,” Eur. J. Neurosci. 27, 2758-2772 (2008).
[CrossRef] [PubMed]

J. Berwick, C. Martin, J. Martindale, M. Jones, D. Johnston, Y. Zheng, P. Redgrave, and J. Mayhew, “Hemodynamic response in the unanesthetized rat: intrinsic optical imaging and spectroscopy of the barrel cortex,” J. Cereb. Blood Flow Metab. 22, 670-679 (2002).
[CrossRef] [PubMed]

J. Mayhew, Y. Zheng, Y. Hou, B. Vuksanovic, J. Verwick, S. Askew, and P. Coffey, “Spectroscopic analysis of changes in remitted illumination: the response to increase neural activity in brain,” NeuroImage 10, 304-326 (1999).
[CrossRef] [PubMed]

Muller, G.

A. Roggan, M. Friebel, K. Dorschel, A. Hahn, and G. Muller, “Optical properties of circulating human blood in the wavelength range 400-2500 nm,” J. Biomed. Opt. 4(1), 36-46 (1999).
[CrossRef]

Navas, J.

M. Rojas, J. Navas, and D. Rector, “Evoked response potential markers for anesthetic and behavioral states,” Am. J. Physiol. Regulatory Integrative Comp. Physiol. 291, R189-R196(2006).
[CrossRef]

Nemoto, M.

S. Sheth, M. Nemoto, M. Guiou, M. Walker, N. Pouratian, and A. W. Toga, “Evaluation of coupling between optical intrinsic signals and neuronal activity in rat somatosensory cortex,” NeuroImage 19, 884-894 (2003).
[CrossRef] [PubMed]

Obál, F.

J. Krueger and F. Obál, “A neuronal group theory of sleep function,” J. Sleep Res. 2, 63-69 (1993).
[CrossRef] [PubMed]

Penfield, W.

W. Penfield and H. H. Jasper, Epilepsy and the Functional Anatomy of the Human Brain (Little, Brown, 1954).

Perani, D.

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

Pittman, R. N.

R. N. Pittman, “In vivo photometric analysis of hemoglobin,” Ann. Biomed. Eng. 14, 119-137 (1986).
[CrossRef] [PubMed]

Pouratian, N.

S. Sheth, M. Nemoto, M. Guiou, M. Walker, N. Pouratian, and A. W. Toga, “Evaluation of coupling between optical intrinsic signals and neuronal activity in rat somatosensory cortex,” NeuroImage 19, 884-894 (2003).
[CrossRef] [PubMed]

Prahl, S.

S. Prahl, “Tabulated molar extinction coefficient for hemoglobin in water,” Oregon Medical Laser Company, http://omlc.ogi.edu/spectra/hemoglobin/index.html.

Prahl, S. A.

W. F. Cheong, S. A. Prahl, and A. J. Welch, “A review of the optical properties of biological tissues,” IEEE J. Quantum Electron. 26, 2166-2185 (1990).
[CrossRef]

Rector, D.

M. Rojas, J. Navas, and D. Rector, “Evoked response potential markers for anesthetic and behavioral states,” Am. J. Physiol. Regulatory Integrative Comp. Physiol. 291, R189-R196(2006).
[CrossRef]

Rector, D. M.

D. M. Rector, I. A. Topchiy, K. M. Carter, and M. J. Rojas, “Local functional state differences between rat cortical columns,” Brain Res. 1047, 45-55 (2005).
[CrossRef] [PubMed]

D. M. Rector, K. M. Carter, P. L. Volegov, and J. S. George, “Spatio-temporal mapping of rat whisker barrels with fast scattered light signals,” NeuroImage 26, 619-627(2005).
[CrossRef] [PubMed]

D. M. Rector and J. S. George, “Continuous image and electrophysiological recording with real time processing and control,” Methods 25, 151-163 (2001).
[CrossRef]

D. M. Rector, J. L. Schei, and M. J. Rojas, “Mechanisms underlying state dependent surface-evoked response patterns,” Neurosci. doi: 10.1016/j.neuroscience.2008.11.031.

Redgrave, P.

M. Jones, I. Devonshire, J. Berwick, C. Martin, P. Redgrave, and J. Mayhew, “Altered neurovascular coupling during information-processing states,” Eur. J. Neurosci. 27, 2758-2772 (2008).
[CrossRef] [PubMed]

J. Berwick, C. Martin, J. Martindale, M. Jones, D. Johnston, Y. Zheng, P. Redgrave, and J. Mayhew, “Hemodynamic response in the unanesthetized rat: intrinsic optical imaging and spectroscopy of the barrel cortex,” J. Cereb. Blood Flow Metab. 22, 670-679 (2002).
[CrossRef] [PubMed]

Rhodes, C.

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

Roe, A. W.

L. M. Chen, R. M. Friedman, and A. W. Roe, “Optical imaging of SI topography in anesthetized and awake squirrel monkeys,” J. Neurosci. 25, 7648-7659 (2005).
[CrossRef] [PubMed]

Roggan, A.

A. Roggan, M. Friebel, K. Dorschel, A. Hahn, and G. Muller, “Optical properties of circulating human blood in the wavelength range 400-2500 nm,” J. Biomed. Opt. 4(1), 36-46 (1999).
[CrossRef]

Rojas, M.

M. Rojas, J. Navas, and D. Rector, “Evoked response potential markers for anesthetic and behavioral states,” Am. J. Physiol. Regulatory Integrative Comp. Physiol. 291, R189-R196(2006).
[CrossRef]

Rojas, M. J.

D. M. Rector, I. A. Topchiy, K. M. Carter, and M. J. Rojas, “Local functional state differences between rat cortical columns,” Brain Res. 1047, 45-55 (2005).
[CrossRef] [PubMed]

D. M. Rector, J. L. Schei, and M. J. Rojas, “Mechanisms underlying state dependent surface-evoked response patterns,” Neurosci. doi: 10.1016/j.neuroscience.2008.11.031.

Schei, J. L.

D. M. Rector, J. L. Schei, and M. J. Rojas, “Mechanisms underlying state dependent surface-evoked response patterns,” Neurosci. doi: 10.1016/j.neuroscience.2008.11.031.

Selbie, S.

A. R. Braun, T. J. Balkin, N. J. Wesensten, R. E. Carson, M. Varga, P. Baldwin, S. Selbie, G. Bleneky, and P. Herscovitch, “Regional cerebral blood flow throughout the sleep-wake cycle: an H2O15 PET study,” Brain 120, 1173-1197 (1997).
[CrossRef] [PubMed]

Sheth, S.

S. Sheth, M. Nemoto, M. Guiou, M. Walker, N. Pouratian, and A. W. Toga, “Evaluation of coupling between optical intrinsic signals and neuronal activity in rat somatosensory cortex,” NeuroImage 19, 884-894 (2003).
[CrossRef] [PubMed]

Skoch, J.

E. M. C. Hillman, A. Devor, M. B. Bouchard, A. K. Dunn, G. W. Krauss, J. Skoch, B. J. Bacskai, A. M. Dale, and D. A. Boas, “Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation,” NeuroImage 35, 89-104 (2007).
[CrossRef] [PubMed]

Spinks, T.

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

Tamura, M.

Y. Hoshi and M. Tamura, “Dynamic multichannel near-infrared optical imaging of human brain activity,” J. Appl. Physiol. 75, 1842-1846 (1993).
[PubMed]

Toga, A. W.

S. Sheth, M. Nemoto, M. Guiou, M. Walker, N. Pouratian, and A. W. Toga, “Evaluation of coupling between optical intrinsic signals and neuronal activity in rat somatosensory cortex,” NeuroImage 19, 884-894 (2003).
[CrossRef] [PubMed]

Topchiy, I. A.

D. M. Rector, I. A. Topchiy, K. M. Carter, and M. J. Rojas, “Local functional state differences between rat cortical columns,” Brain Res. 1047, 45-55 (2005).
[CrossRef] [PubMed]

Ulbert, I.

A. Devor, A. K. Dunn, M. L. Andermann, I. Ulbert, D. A. Boas, and A. M. Dale, “Coupling of total hemoglobin concentration oxygenation, and neural activity in rat somatosensory cortex,” Neuron 39, 353-359 (2003).
[CrossRef] [PubMed]

Varga, M.

A. R. Braun, T. J. Balkin, N. J. Wesensten, R. E. Carson, M. Varga, P. Baldwin, S. Selbie, G. Bleneky, and P. Herscovitch, “Regional cerebral blood flow throughout the sleep-wake cycle: an H2O15 PET study,” Brain 120, 1173-1197 (1997).
[CrossRef] [PubMed]

Verwick, J.

J. Mayhew, Y. Zheng, Y. Hou, B. Vuksanovic, J. Verwick, S. Askew, and P. Coffey, “Spectroscopic analysis of changes in remitted illumination: the response to increase neural activity in brain,” NeuroImage 10, 304-326 (1999).
[CrossRef] [PubMed]

Volegov, P. L.

D. M. Rector, K. M. Carter, P. L. Volegov, and J. S. George, “Spatio-temporal mapping of rat whisker barrels with fast scattered light signals,” NeuroImage 26, 619-627(2005).
[CrossRef] [PubMed]

Vuksanovic, B.

J. Mayhew, Y. Zheng, Y. Hou, B. Vuksanovic, J. Verwick, S. Askew, and P. Coffey, “Spectroscopic analysis of changes in remitted illumination: the response to increase neural activity in brain,” NeuroImage 10, 304-326 (1999).
[CrossRef] [PubMed]

Walker, A.

G. Zoccoli, A. Walker, P. Lenzi, and C. Franzini, “The cerebral circulation during sleep: regulation mechanisms and functional implications,” Sleep Med, Rev. 6, 443-455 (2002).
[CrossRef]

Walker, M.

S. Sheth, M. Nemoto, M. Guiou, M. Walker, N. Pouratian, and A. W. Toga, “Evaluation of coupling between optical intrinsic signals and neuronal activity in rat somatosensory cortex,” NeuroImage 19, 884-894 (2003).
[CrossRef] [PubMed]

Welch, A. J.

W. F. Cheong, S. A. Prahl, and A. J. Welch, “A review of the optical properties of biological tissues,” IEEE J. Quantum Electron. 26, 2166-2185 (1990).
[CrossRef]

Wesensten, N. J.

A. R. Braun, T. J. Balkin, N. J. Wesensten, R. E. Carson, M. Varga, P. Baldwin, S. Selbie, G. Bleneky, and P. Herscovitch, “Regional cerebral blood flow throughout the sleep-wake cycle: an H2O15 PET study,” Brain 120, 1173-1197 (1997).
[CrossRef] [PubMed]

Wise, R. J. S.

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

Xiong, Y.

C. Chen-Bee, T. Agoncillo, Y. Xiong, and R. Frostig, “The triphasic intrinsic signal: implications for functional imaging,” J. Neurosci. 75, 4572-4586 (2007).
[CrossRef]

Zheng, Y.

J. Berwick, C. Martin, J. Martindale, M. Jones, D. Johnston, Y. Zheng, P. Redgrave, and J. Mayhew, “Hemodynamic response in the unanesthetized rat: intrinsic optical imaging and spectroscopy of the barrel cortex,” J. Cereb. Blood Flow Metab. 22, 670-679 (2002).
[CrossRef] [PubMed]

J. Mayhew, Y. Zheng, Y. Hou, B. Vuksanovic, J. Verwick, S. Askew, and P. Coffey, “Spectroscopic analysis of changes in remitted illumination: the response to increase neural activity in brain,” NeuroImage 10, 304-326 (1999).
[CrossRef] [PubMed]

Zoccoli, G.

G. Zoccoli, A. Walker, P. Lenzi, and C. Franzini, “The cerebral circulation during sleep: regulation mechanisms and functional implications,” Sleep Med, Rev. 6, 443-455 (2002).
[CrossRef]

Am. J. Physiol. Regulatory Integrative Comp. Physiol. (1)

M. Rojas, J. Navas, and D. Rector, “Evoked response potential markers for anesthetic and behavioral states,” Am. J. Physiol. Regulatory Integrative Comp. Physiol. 291, R189-R196(2006).
[CrossRef]

Ann. Biomed. Eng. (1)

R. N. Pittman, “In vivo photometric analysis of hemoglobin,” Ann. Biomed. Eng. 14, 119-137 (1986).
[CrossRef] [PubMed]

Brain (2)

K. L. Leenders, D. Perani, A. A. Lammertsma, J. D. Heather, P. Buckingham, M. J. R. Healy, J. M. Gibbs, R. J. S. Wise, J. Hatazawa, S. Herold, R. P. Beaney, D. J. Brooks, T. Spinks, C. Rhodes, R. S. J. Frackowiak, and T. Jones, “Cerebral blood flow, blood volume, and oxygen utilization,” Brain 113, 27-47 (1990).
[CrossRef] [PubMed]

A. R. Braun, T. J. Balkin, N. J. Wesensten, R. E. Carson, M. Varga, P. Baldwin, S. Selbie, G. Bleneky, and P. Herscovitch, “Regional cerebral blood flow throughout the sleep-wake cycle: an H2O15 PET study,” Brain 120, 1173-1197 (1997).
[CrossRef] [PubMed]

Brain Res. (1)

D. M. Rector, I. A. Topchiy, K. M. Carter, and M. J. Rojas, “Local functional state differences between rat cortical columns,” Brain Res. 1047, 45-55 (2005).
[CrossRef] [PubMed]

Eur. J. Neurosci. (1)

M. Jones, I. Devonshire, J. Berwick, C. Martin, P. Redgrave, and J. Mayhew, “Altered neurovascular coupling during information-processing states,” Eur. J. Neurosci. 27, 2758-2772 (2008).
[CrossRef] [PubMed]

IEEE J. Quantum Electron. (1)

W. F. Cheong, S. A. Prahl, and A. J. Welch, “A review of the optical properties of biological tissues,” IEEE J. Quantum Electron. 26, 2166-2185 (1990).
[CrossRef]

J. Appl. Physiol. (1)

Y. Hoshi and M. Tamura, “Dynamic multichannel near-infrared optical imaging of human brain activity,” J. Appl. Physiol. 75, 1842-1846 (1993).
[PubMed]

J. Biomed. Opt. (1)

A. Roggan, M. Friebel, K. Dorschel, A. Hahn, and G. Muller, “Optical properties of circulating human blood in the wavelength range 400-2500 nm,” J. Biomed. Opt. 4(1), 36-46 (1999).
[CrossRef]

J. Cereb. Blood Flow Metab. (1)

J. Berwick, C. Martin, J. Martindale, M. Jones, D. Johnston, Y. Zheng, P. Redgrave, and J. Mayhew, “Hemodynamic response in the unanesthetized rat: intrinsic optical imaging and spectroscopy of the barrel cortex,” J. Cereb. Blood Flow Metab. 22, 670-679 (2002).
[CrossRef] [PubMed]

J. Neurosci. (2)

L. M. Chen, R. M. Friedman, and A. W. Roe, “Optical imaging of SI topography in anesthetized and awake squirrel monkeys,” J. Neurosci. 25, 7648-7659 (2005).
[CrossRef] [PubMed]

C. Chen-Bee, T. Agoncillo, Y. Xiong, and R. Frostig, “The triphasic intrinsic signal: implications for functional imaging,” J. Neurosci. 75, 4572-4586 (2007).
[CrossRef]

J. Sleep Res. (2)

J. Krueger and F. Obál, “A neuronal group theory of sleep function,” J. Sleep Res. 2, 63-69 (1993).
[CrossRef] [PubMed]

P. Maquet, “Functional neuroimaging of normal human sleep by positron emission tomography,” J. Sleep Res. 9, 207-231(2000).
[CrossRef] [PubMed]

Methods (1)

D. M. Rector and J. S. George, “Continuous image and electrophysiological recording with real time processing and control,” Methods 25, 151-163 (2001).
[CrossRef]

NeuroImage (5)

E. M. C. Hillman, A. Devor, M. B. Bouchard, A. K. Dunn, G. W. Krauss, J. Skoch, B. J. Bacskai, A. M. Dale, and D. A. Boas, “Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation,” NeuroImage 35, 89-104 (2007).
[CrossRef] [PubMed]

A. K. Dunn, A. Devor, A. M. Dale, and D. A. Boas, “Spatial extent of oxygen metabolism and hemodynamic changes during functional activation of the rat somatosensory cortex,” NeuroImage 27, 279-290 (2005).
[CrossRef] [PubMed]

J. Mayhew, Y. Zheng, Y. Hou, B. Vuksanovic, J. Verwick, S. Askew, and P. Coffey, “Spectroscopic analysis of changes in remitted illumination: the response to increase neural activity in brain,” NeuroImage 10, 304-326 (1999).
[CrossRef] [PubMed]

S. Sheth, M. Nemoto, M. Guiou, M. Walker, N. Pouratian, and A. W. Toga, “Evaluation of coupling between optical intrinsic signals and neuronal activity in rat somatosensory cortex,” NeuroImage 19, 884-894 (2003).
[CrossRef] [PubMed]

D. M. Rector, K. M. Carter, P. L. Volegov, and J. S. George, “Spatio-temporal mapping of rat whisker barrels with fast scattered light signals,” NeuroImage 26, 619-627(2005).
[CrossRef] [PubMed]

Neuron (1)

A. Devor, A. K. Dunn, M. L. Andermann, I. Ulbert, D. A. Boas, and A. M. Dale, “Coupling of total hemoglobin concentration oxygenation, and neural activity in rat somatosensory cortex,” Neuron 39, 353-359 (2003).
[CrossRef] [PubMed]

Neurosci. (1)

D. M. Rector, J. L. Schei, and M. J. Rojas, “Mechanisms underlying state dependent surface-evoked response patterns,” Neurosci. doi: 10.1016/j.neuroscience.2008.11.031.

Sleep Med, Rev. (1)

G. Zoccoli, A. Walker, P. Lenzi, and C. Franzini, “The cerebral circulation during sleep: regulation mechanisms and functional implications,” Sleep Med, Rev. 6, 443-455 (2002).
[CrossRef]

Other (2)

W. Penfield and H. H. Jasper, Epilepsy and the Functional Anatomy of the Human Brain (Little, Brown, 1954).

S. Prahl, “Tabulated molar extinction coefficient for hemoglobin in water,” Oregon Medical Laser Company, http://omlc.ogi.edu/spectra/hemoglobin/index.html.

Cited By

OSA participates in CrossRef's Cited-By Linking service. Citing articles from OSA journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (6)

Fig. 1
Fig. 1

A 1 mm diameter photodiode (A) was coupled to a 1 mm optical fiber encased in hypodermic tubing and covered with black epoxy. The distal end of the optical fiber was cut to 8 mm length, polished, and placed directly in contact with the cortical tissue to collect light from the cortex. To illuminate the tissue with 660 nm light, a LED (B) was cut down to a 1 mm width and covered with black epoxy. Rats (C) were implanted with a LED and photodiode pair that was placed over the right temporal ridge (T) and 3 mm caudal to bregma (B) with 3 mm between the LED and the photodiode. To assess behavioral state, EEG screw electrodes were implanted in the frontal and parietal lobes and a ground reference screw was placed in the occipital lobe (solid circles). Five additional screws served as anchors for the headstage (open circles). Neck EMG and EKG wires recorded muscle activity and heart rate.

Fig. 2
Fig. 2

Top trace, sensitivity of the optical signal to oxyhemoglobin changes as a function of wavelength, described by Eq. (A7), for varying initial oxygenated hemoglobin saturation conditions. At 660 nm , the optical signal is more sensitive to changes in deoxyhemoglobin with higher oxyhemoglobin saturation. The lower trace shows the sensitivity of the optical signal to changes in blood volume for varying initial oxygenated hemoglobin saturation conditions. At 660 nm , the optical signal is less sensitive to changes in blood volume with higher oxyhemoglobin saturation, described by Eq. (A11). An inset of the hemoglobin absorption curve is shown with a line drawn at 660 nm .

Fig. 3
Fig. 3

Sample evoked electrical responses from one animal for wake, sleep, and anesthetized states were averaged across stimuli and plotted across time. The vertical lines represent each stimulus in the burst. The ERP amplitude, measured from the first peak (P1) to the first trough (N1), was significantly larger during QS than during wake. During REM sleep, the ERP was similar in amplitude to the ERP during wake. Under isoflurane anesthesia, a small amplitude ERP appeared after the first stimulus followed by a late burst of activity synchronized to the stimulus. The lower inset panel demonstrates electrical recordings from a different rat using single click stimuli. The top trace shows several burst events that synchronize to the stimulus and are stacked on top of each other. The bottom trace shows the corresponding average of the bursts, which appears very similar to a late ERP but is unrelated to mechanisms that underlie the ERP [11]. The dotted line indicates the time of the stimulus.

Fig. 4
Fig. 4

Inverted evoked optical responses were averaged across wake, sleep, and anesthetized states and plotted across time in this example from one rat. The vertical lines represent each stimulus in the burst. To compare sleep state related responses, the wake, QS, and REM traces were normalized to the QS peak while the isoflurane trace was reported as fractional change from baseline, prestimulus conditions. An increase in the inverted signal corresponded to an increase in 660 nm light absorption (a decrease in reflected light) and an increase in deoxyhemoglobin/blood volume. The peak amplitude was larger during QS than wake and REM, but the trough amplitude did not significantly differ. Both the peak and the trough were shifted later in time during QS than wake, REM, and isoflurane.

Fig. 5
Fig. 5

Optical response traces from four animals for (A) wake, (B) QS, (C) REM, and (D) isoflurane. The peaks and troughs, marked by arrows, show the amplitude and timing trends. The variability between rats may be caused by different amounts of movement artifact and/or placement differences. During wake, rat 4 showed a large, late trough that may have been influenced by a movement artifact. Rat 3 showed thicker traces in QS and REM, as well as rat 4 during isoflurane due to decreased signal-to-noise in these recordings.

Fig. 6
Fig. 6

Peak amplitude versus time plotted for all four animals across states (A). The wake/sleep responses were normalized to the QS peak while the isoflurane response was reported as changes from baseline. The mean peak amplitudes and times are plotted with vertical and horizontal standard error bars, respectively. During QS, the peak amplitude was significantly larger compared to wake and REM. The QS peak was shifted significantly later in time compared to isoflurane. The trough amplitude versus time are plotted for all four animals across states along with the mean and standard error (circled region). Unlike the peak, the QS trough amplitude did not significantly differ between wake and REM, but it occurred significantly later in time compared to isoflurane. A plot of the optical amplitude (peak–trough) versus the ERP amplitude (P1-N1) for individual recordings is shown in B. Wake states exhibited lower amplitude ERP and optical responses while QS states exhibited larger ERP and optical amplitudes. Evoked responses during REM were similar in amplitude to wake responses, but experienced larger variations between animals. During isoflurane, the optical response was similar in amplitude to QS, and the synchronized burst amplitudes were similar to QS ERP amplitudes.

Tables (1)

Tables Icon

Table 1 Mean and Standard Error Values of the Electrical and Optical Responses from Four Animals a

Equations (11)

Equations on this page are rendered with MathJax. Learn more.

I = I 0 10 μ λ d ,
μ λ = ε λ HbO 2 c + ε λ Hb c .
A = log ( I 0 I ) ,
A = S ε λ HbO 2 c d + ( 1 S ) ε λ Hb c d ,
d A λ d S = ε λ HbO 2 c d ε λ Hb c d .
c d = A ( S ε λ HbO 2 + ( 1 S ) ε λ Hb ) .
d A λ d S = A ( ε λ HbO 2 ε λ Hb ) ( S ε λ HbO 2 + ( 1 S ) ε λ Hb ) ,
μ λ = ( 1 V ) μ tissue + V ( S ε λ HbO 2 c + ( 1 S ) ε λ Hb c ) ,
d A λ d V = μ tissue d + S ε λ HbO 2 c d + ( 1 S ) ε λ Hb c d ,
d = A [ 1 ( 1 V ) μ tissue + V S ε λ HbO 2 c + V ( 1 S ) ε λ Hb c ] .
d A λ d V = A ( μ tissue + S ε λ HbO 2 c + ( 1 S ) ε λ Hb c ) ( 1 V ) μ tissue + V S ε λ HbO 2 c + V ( 1 S ) ε λ Hb c ,

Metrics