On-Line Near-Infrared Spectrometer to Monitor Urea Removal in Real Time During Hemodialysis

Not Accessible

Your library or personal account may give you access

Abstract

The <i>ex vivo</i> removal of urea during hemodialysis treatments is monitored in real time with a noninvasive near-infrared spectrometer. The spectrometer uses a temperature-controlled acousto optical tunable filter (AOFT) in conjunction with a thermoelectrically cooled extended wavelength InGaAs detector to provide spectra with a 20 cm<sup>−1</sup> resolution over the combination region (4000–5000 cm<sup>−1</sup>) of the near-infrared spectrum. Spectra are signal averaged over 15 seconds to provide root mean square noise levels of 24 micro-absorbance units for 100% lines generated over the 4600–4500 cm<sup>−1</sup> spectral range. Combination spectra of the spent dialysate stream are collected in real-time as a portion of this stream passes through a sample holder constructed from a 1.1 mm inner diameter tube of Teflon. Real-time spectra are collected during 17 individual dialysis sessions over a period of 10 days. Reference samples were extracted periodically during each session to generate 87 unique samples with corresponding reference concentrations for urea, glucose, lactate, and creatinine. A series of calibration models are generated for urea by using the partial least squares (PLS) algorithm and each model is optimized in terms of number of factors and spectral range. The best calibration model gives a standard error of prediction (SEP) of 0.30 mM based on a random splitting of spectra generated from all 87 reference samples collected across the 17 dialysis sessions. PLS models were also developed by using spectra collected in early sessions to predict urea concentrations from spectra collected in subsequent sessions. SEP values for these prospective models range from 0.37 mM to 0.52 mM. Although higher than when spectra are pooled from all 17 sessions, these prospective SEP values are acceptable for monitoring the hemodialysis process. Selectivity for urea is demonstrated and the selectivity properties of the PLS calibration models are characterized with a pure component selectivity analysis.

PDF Article
More Like This
Analyzing the serum of hemodialysis patients with end-stage chronic kidney disease by means of the combination of SERS and machine learning

Lyudmila A. Bratchenko, Sahar Z. Al-Sammarraie, Elena N. Tupikova, Daria Y. Konovalova, Peter A. Lebedev, Valery P. Zakharov, and Ivan A. Bratchenko
Biomed. Opt. Express 13(9) 4926-4938 (2022)

Evaluation of Kromoscopy: resolution of glucose and urea

Anna M. Helwig, Mark A. Arnold, and Gary W. Small
Appl. Opt. 39(25) 4715-4720 (2000)

Real-time LIBS monitoring of laser-based layered controlled paint removal from aircraft skin based on random forest

Dehui Lin, Wenfeng Yang, Ziran Qian, Shaolong Li, Yue Hu, Guo Li, and Sai Zhang
Appl. Opt. 62(10) 2569-2576 (2023)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.