Abstract
Results of supersonic molecular flow-velocity measurements using inverse Raman spectroscopy are reported for the first time to our knowledge. Because of potential wind-tunnel applications, flowing N2 molecules are probed directly, and their flow velocity, temperature, and density are measured. The uncertainties are less than 5% for the velocity measurements and about 10% for the temperature and density measurements. To achieve the quoted precision, I2 fluorescence, I2 saturated-absorption, and differential-detection techniques are used to stabilize the probe laser, provide an absolute-frequency reference, and reduce detection noise, respectively.
© 1983 Optical Society of America
Full Article | PDF ArticleOSA Recommended Articles
H. Moosmüller, G. C. Herring, and C. Y. She
Opt. Lett. 9(12) 536-538 (1984)
Reginald J. Exton and Mervin E. Hillard
Appl. Opt. 25(1) 14-21 (1986)
M. Lefebvre, M. Péalat, and J. Strempel
Opt. Lett. 17(24) 1806-1808 (1992)