Abstract
The carrier-envelope phase (CEP) dependence of few-cycle above-threshold ionization (ATI) of Xe is calibrated for use as a reference measurement for determining and controlling the absolute CEP in other interactions. This is achieved by referencing the CEP-dependent ATI measurements of Xe to measurements of atomic H, which are in turn referenced to ab initio calculations for atomic H. This allows for the accurate determination of the absolute CEP dependence of Xe ATI, which enables relatively easy determination of the offset between the relative CEP measured and/or controlled by typical devices and the absolute CEP in the interaction.
© 2015 Optical Society of America
Full Article | PDF ArticleMore Like This
Yinyu Zhang, Philipp Kellner, Daniel Adolph, Danilo Zille, Philipp Wustelt, Daniel Würzler, Slawomir Skruszewicz, Max Möller, A. Max Sayler, and Gerhard G. Paulus
Opt. Lett. 42(24) 5150-5153 (2017)
D. Adolph, A. M. Sayler, T. Rathje, K. Rühle, and G. G. Paulus
Opt. Lett. 36(18) 3639-3641 (2011)
Duke A. Debrah, Gabriel A. Stewart, Gihan Basnayake, John W. G. Tisch, Suk Kyoung Lee, and Wen Li
Opt. Lett. 44(14) 3582-3585 (2019)