Abstract

Back-focal-plane detection of micrometer-sized beads offers subnanometer resolution for single-molecule, optical trapping experiments. However, laser beam-pointing instability and mechanical drift of the microscope limit the resolution of optical-trapping experiments. By combining two infrared lasers with improved differential beam-pointing stability <0.05 µrad, we simultaneously measure and subtract the motion of the microscope stage, leading to a resolution of <0.1 nm in 1 ms and stability of 0.5 nm over 60 s. Repeated steps of 0.4 nm at 1 Hz are resolved with a signal-to-noise ratio of 25.

© 2004 Optical Society of America

Full Article  |  PDF Article
More Like This
Stabilization of an optical microscope to 0.1 nm in three dimensions

Ashley R. Carter, Gavin M. King, Theresa A. Ulrich, Wayne Halsey, David Alchenberger, and Thomas T. Perkins
Appl. Opt. 46(3) 421-427 (2007)

Ultrastable measurement platform: sub-nm drift over hours in 3D at room temperature

Robert Walder, D. Hern Paik, Matthew S. Bull, Carl Sauer, and Thomas T. Perkins
Opt. Express 23(13) 16554-16564 (2015)

Simple way to correct the drift in surface-coupled optical tweezers using the laser reflection pattern

Wenzhao Liu, Zhensheng Zhong, and Jie Ma
Opt. Express 29(12) 18769-18780 (2021)

References

You do not have subscription access to this journal. Citation lists with outbound citation links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (3)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Metrics

You do not have subscription access to this journal. Article level metrics are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription