Abstract

We correct the errors in the uncertainty budget. The determined ratio (ν Yb/ν Sr) is corrected to be 1.207 507 039 343 341 2(17) with a fractional standard uncertainty of 1.4 × 10−15.

© 2014 Optical Society of America

Full Article  |  PDF Article
OSA Recommended Articles
Frequency ratio measurement of 171Yb and 87Sr optical lattice clocks

Daisuke Akamatsu, Masami Yasuda, Hajime Inaba, Kazumoto Hosaka, Takehiko Tanabe, Atsushi Onae, and Feng-Lei Hong
Opt. Express 22(7) 7898-7905 (2014)

Direct comparison of a Ca+ single-ion clock against a Sr lattice clock to verify the absolute frequency measurement

Kensuke Matsubara, Hidekazu Hachisu, Ying Li, Shigeo Nagano, Clayton Locke, Asahiko Nogami, Masatoshi Kajita, Kazuhiro Hayasaka, Tetsuya Ido, and Mizuhiko Hosokawa
Opt. Express 20(20) 22034-22041 (2012)

Absolute frequency measurement of the 435.5-nm 171Yb+-clock transition with a Kerr-lens mode-locked femtosecond laser

Jörn Stenger, Christian Tamm, Nils Haverkamp, Stefan Weyers, and Harald R. Telle
Opt. Lett. 26(20) 1589-1591 (2001)

References

  • View by:
  • |
  • |
  • |

  1. D. Akamatsu, M. Yasuda, H. Inaba, K. Hosaka, T. Tanabe, A. Onae, and F.-L. Hong, “Frequency ratio measurement of 171Yb and 87Sr optical lattice clocks,” Opt. Express 22(7), 7898–7905 (2014).
    [Crossref] [PubMed]

2014 (1)

Akamatsu, D.

Hong, F.-L.

Hosaka, K.

Inaba, H.

Onae, A.

Tanabe, T.

Yasuda, M.

Cited By

OSA participates in Crossref's Cited-By Linking service. Citing articles from OSA journals and other participating publishers are listed here.

Alert me when this article is cited.


Tables (1)

Tables Icon

Table 1 The fractional uncertainties and corrections of the Sr OLC, Yb OLC, and the frequency ratio measurement. The asterisks represent the value depending on the measurements.

Metrics