Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

All-optical quantum random bit generation from intrinsically binary phase of parametric oscillators

Open Access Open Access

Abstract

We demonstrate a novel all-optical quantum random number generator (RNG) based on above-threshold binary phase state selection in a degenerate optical parametric oscillator (OPO). Photodetection is not a part of the random process, and no post processing is required for the generated bit sequence. We show that the outcome is statistically random with 99% confidence, and verify that the randomness is due to the phase of initiating photons generated through spontaneous parametric down conversion of the pump, with negligible contribution of classical noise sources. With the use of micro- and nanoscale OPO resonators, this technique offers a promise for simple, robust, and high-speed on-chip all-optical quantum RNGs.

© 2012 Optical Society of America

Full Article  |  PDF Article
More Like This
5-bit all-optical quantum random number generator based on a time-multiplexed optical parametric oscillator

Shaojie Li, Xiaoxuan Zhu, Jintao Fan, Kai Wen, and Minglie Hu
Opt. Express 31(23) 38939-38948 (2023)

Direct generation of all-optical random numbers from optical pulse amplitude chaos

Pu Li, Yun-Cai Wang, An-Bang Wang, Ling-Zhen Yang, Ming-Jiang Zhang, and Jian-Zhong Zhang
Opt. Express 20(4) 4297-4308 (2012)

A robust random number generator based on differential comparison of chaotic laser signals

Jianzhong Zhang, Yuncai Wang, Ming Liu, Lugang Xue, Pu Li, Anbang Wang, and Mingjiang Zhang
Opt. Express 20(7) 7496-7506 (2012)

Supplementary Material (1)

Media 1: AVI (4857 KB)     

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (5)

Fig. 1.
Fig. 1. (a) Phase sensitive gain in a degenerate OPO – the amplitude incremental gain of the signal (g|s|) versus the relative phase between the pump and the signal – (θs = ϕsϕp/2 +π/4, where ϕs and ϕp are the signal and pump phases, respectively), (b) Schematic of the all-optical quantum RNG. PD: Photodetector, BS: non-polarizing beam splitter, (c) Electric fields of the signal pulses compared to the pump in the two possible phase states of a short-pulse degenerate OPO.
Fig. 2.
Fig. 2. (a) Schematic of the experimental setup consisting of the twin degenerate OPO followed by an un-equal arm Michelson interferometer. The round-trip length difference of the arms in the interferometer is equal to the separation length of pump pulses. The output of the interferometer is filtered to eliminate the pump. An AOM is used to restart the twin OPO at a clock rate of 10 kbps, while the zeroth order output (non-diffracted beam) pumps the OPO. The detector PD1 and a piezoelectric transducer (PZT) on M4 are parts of the “dither-and-lock” servo loop for stabilizing the cavity length to a resonance [16]. The interferometer arm length difference is stabilized using the interference of the undepleted pump and a PZT on M11 (not shown in this schematic) resulting in a fringe visibility of greater than 60% throughout the experiment. OC: Output Coupler, (b) Pump and signal pulse trains for a twin OPO in which the cavity roundtrip time (Tcavity) is twice the repetition period of the pump (Trep); this results in two independent OPOs with signal pulse trains at half the repetition frequency of the pump, marked by OPO1 and OPO2 on the pulse trains.
Fig. 3.
Fig. 3. (a) Optical spectrum of the pump and signal, (b) complementary fringe patterns at the output of the Michelson interferometer, i.e. maximum on one pattern is minimum on the other and vice versa, (c) (Media 1) sample time domain signal of the interferometer output, i.e. the random sequence, along with the clock signal at 10 kbps.
Fig. 4.
Fig. 4. Summary of the results of the NIST statistical tests [19] on a sequence of 1 billion bits. The sequence is chopped into 500 shorter sequences and each test is performed on all sequences. Horizontal axes shows the name of the tests, P – Value is the result of χ2 distribution evaluation for all short sequences, and Proportion is the proportion of the short sequences passed each test with a significance level of 0.01. The final decision on if the whole sequence has passed a test is made based on these criteria: P – Value > 0.0001 and Proportion > 0.976 [19], which are satisfied for all the tests.
Fig. 5.
Fig. 5. (a) Dependence of the randomness on the clock speed; for each clock speed a sequence of 100 kb is recorded, and the rate of bit flip is calculated by counting the number of changes in the bit value and dividing it to the sequence length, for a random sequence the rate of bit flip is close to 0.5 and for a single-value sequence it is zero; The transition from random to non-random output occurred around 25 kbps which is close to the estimated value of 30 kbps taking into account the experiment parameters. This value can be increased by decreasing the overall pump power and approaching the threshold. To record the 1 Gb of data, the pump power was reduced so that the randomness would not break until 200 kbps (the measurement limit). (b, c, d) a sample of the output sequence when clock speed is (b) 20 kbps, (c) 30 kbps, and (d) 40 kbps.

Equations (1)

Equations on this page are rendered with MathJax. Learn more.

τ off = T 2 δ E 2 δ E P off P t h ,
Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.