Abstract

We report a mechanistic analysis of photodamage in coherent anti-Stokes Raman scattering (CARS) microscopy. Photodamage to the myelin sheath in spinal tissues is induced by using the point scan mode and is featured by myelin splitting and shockwaves with broadband emission. Our measurement of photodamage rate versus the excitation power reveals that both linear and nonlinear mechanisms are involved. Moreover, we show that vibrational absorption induced by coherent Raman processes significantly contributes to the nonlinear damage at high peak powers. For CARS imaging of cultured cells, the photodamage is characterized by plasma membrane blebbing and is dominated by a second order mechanism. Our study suggests that for dense samples such as the myelin sheath, CARS imaging induced photodamage can be minimized by using laser beams with relatively long near IR wavelengths and a repetition rate of a few MHz. For less dense samples such as cultured cells, laser pulses of higher repetition rates are preferred.

© 2006 Optical Society of America

PDF Article

References

  • View by:
  • |
  • |
  • |

  1. W. Denk, J. H. Strickler, and W. W. Webb, "Two-Photon Laser Scanning Fluorescence Microscopy," Science 248, 73-76 (1990).
    [CrossRef]
  2. C. Xu, W. Zipfel, J. B. Shear, R. M. Williams, and W. W. Webb, "Multiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy," Proc. Natl. Acad. Sci. USA 93, 10763-10768 (1996).
    [CrossRef]
  3. L. Moreaux, O. Sandre, and J. Mertz, "Membrane imaging by second-harmonic generation microscopy," J. Opt. Soc. Am. B 17, 1685-1694 (2000).
  4. P. J. Campagnola and L. M. Loew, "Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms," Nat. Biotech. 21, 1356-1360 (2003).
    [CrossRef]
  5. J. X. Cheng and X. S. Xie, "Coherent anti-Stokes Raman scattering microscopy: instrumentation, theory, and applications," J. Phys. Chem. B 108, 827-840 (2004).
    [CrossRef]
  6. M. D. Duncan, J. Reintjes, and T. J. Manuccia, "Scanning Coherent Anti-Stokes Raman Microscope," Opt. Lett. 7, 350-352 (1982).
  7. A. Zumbusch, G. R. Holtom, and X. S. Xie, "Three-dimensional vibrational imaging by coherent anti-Stokes Raman scattering," Phys. Rev. Lett. 82, 4142-4145 (1999).
    [CrossRef]
  8. J. X. Cheng, A. Volkmer, L. D. Book, and X. S. Xie, "An epi-detected coherent anti-Stokes Raman scattering (E-CARS) microscope with high spectral resolution and high sensitivity," J. Phys. Chem. B 105, 1277-1280 (2001).
    [CrossRef]
  9. A. Volkmer, J. X. Cheng, and X. S. Xie, "Vibrational imaging with high sensitivity via epi-detected coherent anti-Stokes Raman scattering microscopy," Phys. Rev. Lett. 87, 023901 (2001).
    [CrossRef]
  10. G. W. H. Wurpel, J. M. Schins, and M. Müller, "Chemical specificity in three-dimensional imaging with multiplex coherent anti-Stokes Raman scattering microscopy," Opt. Lett. 27, 1093-1095 (2002).
  11. J. X. Cheng, A. Volkmer, and X. S. Xie, "Theoretical and experimental characterization of coherent anti-Stokes Raman scattering microscopy," J. Opt. Soc. Am. B 19,1363-1375 (2002).
  12. N. Dudovich, D. Oron, and Y. Silberberg, "Single-pulse coherently controlled nonlinear Raman spectroscopy and microscopy," Nature 418,512-514 (2002).
    [CrossRef]
  13. C. L. Evans, E. O. Potma, and X. S. Xie, "Coherent anti-Stokes Raman scattering spectral interferometry:determination of the real and imaginary components of nonlinear susceptibility χ(3) for vibrational microscopy," Opt. Lett. 29,2923-2925 (2004).
    [CrossRef]
  14. K. P. Knutsen, J. C. Johnson, A. E. Miller, P. B. Petersen, and R. J. Saykally, "High spectral resolution multiplex CARS spectroscopy using chirped pulses," Chem. Phys. Lett. 387,436-441 (2004).
    [CrossRef]
  15. T. Ichimura, N. Hayazawa, M. Hashimoto, Y. Inouye, and S. Kawata, "Tip-enhanced coherent anti-Stokes Raman scattering for vibrational nanoimaging," Phys. Rev. Lett. 92,220801 (2004).
    [CrossRef]
  16. J. S. Bredfeldt, C. Vinegoni, D. L. Marks, and S. A. Boppart, "Molecular sensitivity optical coherence tomography," Opt. Lett. 30,495-497 (2005).
    [CrossRef]
  17. P. D. Maker and R. W. Terhune, "Study of Optical effects Due to an Induced Polarization Third Order in the Electric Field Strength," Phys. Rev. 137,A801-818 (1965).
    [CrossRef]
  18. Y. R. Shen, The Principles of Nonlinear Optics (John Wiley and Sons Inc., New York, 1984).
  19. L. Li, H. Wang, and J. X. Cheng, "Quantitative coherent anti-Stokes Raman scattering imaging of lipid distribution in co-existing domains," Biophys. J. 89,3480-3490 (2005).
    [CrossRef]
  20. G. W. H. Wurpel, H. A. Rinia, and M. Müller, "Imaging orientational order and lipid density in multilamellar vesicles with multiplex CARS microscopy," J. Microsc. 218,37-45 (2005).
    [CrossRef]
  21. E. O. Potma and X. S. Xie, "Direct visualization of lipid phase segregation in single lipid bilayers with coherent anti-Stokes Raman scattering microscopy," Chem. Phys. Chem. 6, 77-79 (2005).
  22. X. Nan, J. X. Cheng, and X. S. Xie, "Vibrational imaging of lipid droplets in live fibroblast cells using coherent anti-Stokes Raman microscopy," J. Lipid Res. 40,2202-2208 (2003).
  23. C. L. Evans, E. O. Potma, M. Puoris'haag, D. Côté, C. P. Lin, and X. S. Xie, "Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy," Proc. Natl. Acad. Sci. USA 102, 16807-16812 (2005).
    [CrossRef]
  24. J. X. Cheng, S. Pautot, D. A. Weitz, and X. S. Xie, "Ordering of water molecules between phospholipid bilayers visualized by coherent anti-Stokes Raman scattering microscopy," Proc. Natl. Acad. Sci. USA 100, 9826-9830 (2003).
    [CrossRef]
  25. E. O. Potma, W. P. D. Boeij, P. J. M. v. Haastert, and D. A. Wiersma, "Real-time visualization of intracellular hydrodynamics in single living cells," Proc. Natl. Acad. Sci. USA 98,1577-1582 (2001).
    [CrossRef]
  26. A. P. Kennedy, J. Sutcliffe, and J. X. Cheng, "Molecular composition and orientation of myelin figures characterized by coherent anti-Stokes Raman scattering microscopy," Langmuir 21, 6478-6486 (2005).
    [CrossRef]
  27. H. Wang, Y. Fu, P. Zickmund, R. Shi, and J. X. Cheng, "Coherent anti-Stokes Raman scattering imaging of live spinal tissues," Biophys. J. 89, 581-591 (2005).
    [CrossRef]
  28. A. Vogel, J. Noack, G. Huettmann, and G. Paltauf, "Femtosecond-laser-produced low-density plasmas in transparent biological media: a tool for the creation of chemical, thermal, and thermomechanical effects below the optical breakdown threshold," Proc. SPIE 4633A,1-15 (2002).
  29. K. König, "Laser tweezers and multiphoton microscopes in life sciences," Histochem. Cell Biol. 114, 79-92 (2000).
  30. A. Hopt and E. Neher, "Highly nonlinear photodamage in two-photon fluorescence microscopy," Biophys. J. 80, 2029-2036 (2001).
  31. K. König, T. W. Becker, P. Fischer, I. Riemann, and K.-J. Halbhuber, "Pulse-length dependence of cellular response to intense near-infrared laser pulses in multiphoton microscopes," Opt. Lett. 24, 113-115 (1999).
  32. H. J. Koester, D. Baur, R. Uhl, and S. W. Hell, "Ca2+ fluorescence imaging with pico- and femtosecond two-photon excitation: signal and photodamge," Biophys. J. 77, 2226-2236 (1999).
  33. J. S. Gomez, "Coherent Raman Spectroscopy," in Modern Techniques in Raman Spectroscopy, J. J. Laserna, editor. (John Wiley & Sons Inc., New York, 1996).
  34. P. Morell and R. H. Quarles, "Myelin formation, structure, and biochemistry," in Basic Neurochemistry: Molecular, Cellular, and Medical Aspects, G. J. Siegel, B. W. Agranoff, R. W. Alberts, and P. B. Molinoff, eds. (Lippincott Williams & Wilkins, Philadelphia, 1999).
  35. P. N. Prasad, Introduction to biophotonics. (Wiley Interscience, Hoboken, NJ, 2003), pp. 168-175.
  36. J. Diels and W. Rudolph, "Generation of extreme wavelengths," in Ultrashort laser pulse phenomena: fundamentals, techniques, and applications on a femtosecond time scale. (Academic Press, San Diego, 1996), pp. 472-475.
  37. H. R. Griem, "Optical radiation," in Plasma physics in theory and application, W. B. Kunkel, editor. (McGraw-Hill, Inc., New York, 1966), pp. 278-280.
  38. K. C. Neuman, E. H. Chadd, G. F. Liou, K. Bergman, and S. M. Block, "Characterization of photodamage to Escherichia coli in optical traps," Biophys. J. 77, 2856-2863 (1999).
  39. B. R. Masters, P. T. C. So, C. Buehler, N. Barry, J. D. Sutin, W. W. Mantulin, and E. Gratton, "Mitigating thermal mechanical damage potential during two-photon dermal imaging," J. Biomed. Opt. 9, 1265-1270 (2004).
    [CrossRef]
  40. Y. Liu, G. J. Sonek, M. W. Berns, and B. J. Tromberg, "Physiological monitoring of optically trapped cells: assessing the effects of confinement by 1064-nm laser tweezers using microfluorometry," Biophys. J. 71, 2158-2167 (1996).
  41. H. Wang, Y. Fu, and J. X. Cheng, "Light-matter energy exchange in coherent Raman microscopy," Phys. Rev. A, submitted (2005).
  42. K. König, H. Liang, M. W. Berns, and B. J. Tromberg, "Cell damage in near-infrared multimode optical traps as a result of multiphoton absorption," Opt. Lett. 21, 1090-1092 (1996).
  43. M. L. Cunningham, J. S. Johnson, S. M. Giovanazzi, and M. J. Peak, "Photosensitized production of superoxide anion by monochromatic (290-405 nm) ultraviolet irradiation of NADH and NADPH coenzymes," Photochem. Photobiol. 42, 125-128 (1985).

2005

L. Li, H. Wang, and J. X. Cheng, "Quantitative coherent anti-Stokes Raman scattering imaging of lipid distribution in co-existing domains," Biophys. J. 89,3480-3490 (2005).
[CrossRef]

G. W. H. Wurpel, H. A. Rinia, and M. Müller, "Imaging orientational order and lipid density in multilamellar vesicles with multiplex CARS microscopy," J. Microsc. 218,37-45 (2005).
[CrossRef]

E. O. Potma and X. S. Xie, "Direct visualization of lipid phase segregation in single lipid bilayers with coherent anti-Stokes Raman scattering microscopy," Chem. Phys. Chem. 6, 77-79 (2005).

C. L. Evans, E. O. Potma, M. Puoris'haag, D. Côté, C. P. Lin, and X. S. Xie, "Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy," Proc. Natl. Acad. Sci. USA 102, 16807-16812 (2005).
[CrossRef]

A. P. Kennedy, J. Sutcliffe, and J. X. Cheng, "Molecular composition and orientation of myelin figures characterized by coherent anti-Stokes Raman scattering microscopy," Langmuir 21, 6478-6486 (2005).
[CrossRef]

H. Wang, Y. Fu, P. Zickmund, R. Shi, and J. X. Cheng, "Coherent anti-Stokes Raman scattering imaging of live spinal tissues," Biophys. J. 89, 581-591 (2005).
[CrossRef]

H. Wang, Y. Fu, and J. X. Cheng, "Light-matter energy exchange in coherent Raman microscopy," Phys. Rev. A, submitted (2005).

J. S. Bredfeldt, C. Vinegoni, D. L. Marks, and S. A. Boppart, "Molecular sensitivity optical coherence tomography," Opt. Lett. 30,495-497 (2005).
[CrossRef]

2004

C. L. Evans, E. O. Potma, and X. S. Xie, "Coherent anti-Stokes Raman scattering spectral interferometry:determination of the real and imaginary components of nonlinear susceptibility χ(3) for vibrational microscopy," Opt. Lett. 29,2923-2925 (2004).
[CrossRef]

K. P. Knutsen, J. C. Johnson, A. E. Miller, P. B. Petersen, and R. J. Saykally, "High spectral resolution multiplex CARS spectroscopy using chirped pulses," Chem. Phys. Lett. 387,436-441 (2004).
[CrossRef]

T. Ichimura, N. Hayazawa, M. Hashimoto, Y. Inouye, and S. Kawata, "Tip-enhanced coherent anti-Stokes Raman scattering for vibrational nanoimaging," Phys. Rev. Lett. 92,220801 (2004).
[CrossRef]

B. R. Masters, P. T. C. So, C. Buehler, N. Barry, J. D. Sutin, W. W. Mantulin, and E. Gratton, "Mitigating thermal mechanical damage potential during two-photon dermal imaging," J. Biomed. Opt. 9, 1265-1270 (2004).
[CrossRef]

J. X. Cheng and X. S. Xie, "Coherent anti-Stokes Raman scattering microscopy: instrumentation, theory, and applications," J. Phys. Chem. B 108, 827-840 (2004).
[CrossRef]

2003

X. Nan, J. X. Cheng, and X. S. Xie, "Vibrational imaging of lipid droplets in live fibroblast cells using coherent anti-Stokes Raman microscopy," J. Lipid Res. 40,2202-2208 (2003).

J. X. Cheng, S. Pautot, D. A. Weitz, and X. S. Xie, "Ordering of water molecules between phospholipid bilayers visualized by coherent anti-Stokes Raman scattering microscopy," Proc. Natl. Acad. Sci. USA 100, 9826-9830 (2003).
[CrossRef]

P. J. Campagnola and L. M. Loew, "Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms," Nat. Biotech. 21, 1356-1360 (2003).
[CrossRef]

2002

N. Dudovich, D. Oron, and Y. Silberberg, "Single-pulse coherently controlled nonlinear Raman spectroscopy and microscopy," Nature 418,512-514 (2002).
[CrossRef]

J. X. Cheng, A. Volkmer, and X. S. Xie, "Theoretical and experimental characterization of coherent anti-Stokes Raman scattering microscopy," J. Opt. Soc. Am. B 19,1363-1375 (2002).

G. W. H. Wurpel, J. M. Schins, and M. Müller, "Chemical specificity in three-dimensional imaging with multiplex coherent anti-Stokes Raman scattering microscopy," Opt. Lett. 27, 1093-1095 (2002).

A. Vogel, J. Noack, G. Huettmann, and G. Paltauf, "Femtosecond-laser-produced low-density plasmas in transparent biological media: a tool for the creation of chemical, thermal, and thermomechanical effects below the optical breakdown threshold," Proc. SPIE 4633A,1-15 (2002).

2001

E. O. Potma, W. P. D. Boeij, P. J. M. v. Haastert, and D. A. Wiersma, "Real-time visualization of intracellular hydrodynamics in single living cells," Proc. Natl. Acad. Sci. USA 98,1577-1582 (2001).
[CrossRef]

J. X. Cheng, A. Volkmer, L. D. Book, and X. S. Xie, "An epi-detected coherent anti-Stokes Raman scattering (E-CARS) microscope with high spectral resolution and high sensitivity," J. Phys. Chem. B 105, 1277-1280 (2001).
[CrossRef]

A. Volkmer, J. X. Cheng, and X. S. Xie, "Vibrational imaging with high sensitivity via epi-detected coherent anti-Stokes Raman scattering microscopy," Phys. Rev. Lett. 87, 023901 (2001).
[CrossRef]

A. Hopt and E. Neher, "Highly nonlinear photodamage in two-photon fluorescence microscopy," Biophys. J. 80, 2029-2036 (2001).

2000

L. Moreaux, O. Sandre, and J. Mertz, "Membrane imaging by second-harmonic generation microscopy," J. Opt. Soc. Am. B 17, 1685-1694 (2000).

K. König, "Laser tweezers and multiphoton microscopes in life sciences," Histochem. Cell Biol. 114, 79-92 (2000).

1999

A. Zumbusch, G. R. Holtom, and X. S. Xie, "Three-dimensional vibrational imaging by coherent anti-Stokes Raman scattering," Phys. Rev. Lett. 82, 4142-4145 (1999).
[CrossRef]

K. König, T. W. Becker, P. Fischer, I. Riemann, and K.-J. Halbhuber, "Pulse-length dependence of cellular response to intense near-infrared laser pulses in multiphoton microscopes," Opt. Lett. 24, 113-115 (1999).

H. J. Koester, D. Baur, R. Uhl, and S. W. Hell, "Ca2+ fluorescence imaging with pico- and femtosecond two-photon excitation: signal and photodamge," Biophys. J. 77, 2226-2236 (1999).

K. C. Neuman, E. H. Chadd, G. F. Liou, K. Bergman, and S. M. Block, "Characterization of photodamage to Escherichia coli in optical traps," Biophys. J. 77, 2856-2863 (1999).

1996

Y. Liu, G. J. Sonek, M. W. Berns, and B. J. Tromberg, "Physiological monitoring of optically trapped cells: assessing the effects of confinement by 1064-nm laser tweezers using microfluorometry," Biophys. J. 71, 2158-2167 (1996).

K. König, H. Liang, M. W. Berns, and B. J. Tromberg, "Cell damage in near-infrared multimode optical traps as a result of multiphoton absorption," Opt. Lett. 21, 1090-1092 (1996).

C. Xu, W. Zipfel, J. B. Shear, R. M. Williams, and W. W. Webb, "Multiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy," Proc. Natl. Acad. Sci. USA 93, 10763-10768 (1996).
[CrossRef]

1990

W. Denk, J. H. Strickler, and W. W. Webb, "Two-Photon Laser Scanning Fluorescence Microscopy," Science 248, 73-76 (1990).
[CrossRef]

1985

M. L. Cunningham, J. S. Johnson, S. M. Giovanazzi, and M. J. Peak, "Photosensitized production of superoxide anion by monochromatic (290-405 nm) ultraviolet irradiation of NADH and NADPH coenzymes," Photochem. Photobiol. 42, 125-128 (1985).

1982

1965

P. D. Maker and R. W. Terhune, "Study of Optical effects Due to an Induced Polarization Third Order in the Electric Field Strength," Phys. Rev. 137,A801-818 (1965).
[CrossRef]

Barry, N.

B. R. Masters, P. T. C. So, C. Buehler, N. Barry, J. D. Sutin, W. W. Mantulin, and E. Gratton, "Mitigating thermal mechanical damage potential during two-photon dermal imaging," J. Biomed. Opt. 9, 1265-1270 (2004).
[CrossRef]

Baur, D.

H. J. Koester, D. Baur, R. Uhl, and S. W. Hell, "Ca2+ fluorescence imaging with pico- and femtosecond two-photon excitation: signal and photodamge," Biophys. J. 77, 2226-2236 (1999).

Becker, T. W.

Bergman, K.

K. C. Neuman, E. H. Chadd, G. F. Liou, K. Bergman, and S. M. Block, "Characterization of photodamage to Escherichia coli in optical traps," Biophys. J. 77, 2856-2863 (1999).

Berns, M. W.

Y. Liu, G. J. Sonek, M. W. Berns, and B. J. Tromberg, "Physiological monitoring of optically trapped cells: assessing the effects of confinement by 1064-nm laser tweezers using microfluorometry," Biophys. J. 71, 2158-2167 (1996).

K. König, H. Liang, M. W. Berns, and B. J. Tromberg, "Cell damage in near-infrared multimode optical traps as a result of multiphoton absorption," Opt. Lett. 21, 1090-1092 (1996).

Block, S. M.

K. C. Neuman, E. H. Chadd, G. F. Liou, K. Bergman, and S. M. Block, "Characterization of photodamage to Escherichia coli in optical traps," Biophys. J. 77, 2856-2863 (1999).

Boeij, W. P. D.

E. O. Potma, W. P. D. Boeij, P. J. M. v. Haastert, and D. A. Wiersma, "Real-time visualization of intracellular hydrodynamics in single living cells," Proc. Natl. Acad. Sci. USA 98,1577-1582 (2001).
[CrossRef]

Book, L. D.

J. X. Cheng, A. Volkmer, L. D. Book, and X. S. Xie, "An epi-detected coherent anti-Stokes Raman scattering (E-CARS) microscope with high spectral resolution and high sensitivity," J. Phys. Chem. B 105, 1277-1280 (2001).
[CrossRef]

Boppart, S. A.

Bredfeldt, J. S.

Buehler, C.

B. R. Masters, P. T. C. So, C. Buehler, N. Barry, J. D. Sutin, W. W. Mantulin, and E. Gratton, "Mitigating thermal mechanical damage potential during two-photon dermal imaging," J. Biomed. Opt. 9, 1265-1270 (2004).
[CrossRef]

Campagnola, P. J.

P. J. Campagnola and L. M. Loew, "Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms," Nat. Biotech. 21, 1356-1360 (2003).
[CrossRef]

Chadd, E. H.

K. C. Neuman, E. H. Chadd, G. F. Liou, K. Bergman, and S. M. Block, "Characterization of photodamage to Escherichia coli in optical traps," Biophys. J. 77, 2856-2863 (1999).

Cheng, J. X.

H. Wang, Y. Fu, P. Zickmund, R. Shi, and J. X. Cheng, "Coherent anti-Stokes Raman scattering imaging of live spinal tissues," Biophys. J. 89, 581-591 (2005).
[CrossRef]

H. Wang, Y. Fu, and J. X. Cheng, "Light-matter energy exchange in coherent Raman microscopy," Phys. Rev. A, submitted (2005).

L. Li, H. Wang, and J. X. Cheng, "Quantitative coherent anti-Stokes Raman scattering imaging of lipid distribution in co-existing domains," Biophys. J. 89,3480-3490 (2005).
[CrossRef]

A. P. Kennedy, J. Sutcliffe, and J. X. Cheng, "Molecular composition and orientation of myelin figures characterized by coherent anti-Stokes Raman scattering microscopy," Langmuir 21, 6478-6486 (2005).
[CrossRef]

J. X. Cheng and X. S. Xie, "Coherent anti-Stokes Raman scattering microscopy: instrumentation, theory, and applications," J. Phys. Chem. B 108, 827-840 (2004).
[CrossRef]

X. Nan, J. X. Cheng, and X. S. Xie, "Vibrational imaging of lipid droplets in live fibroblast cells using coherent anti-Stokes Raman microscopy," J. Lipid Res. 40,2202-2208 (2003).

J. X. Cheng, S. Pautot, D. A. Weitz, and X. S. Xie, "Ordering of water molecules between phospholipid bilayers visualized by coherent anti-Stokes Raman scattering microscopy," Proc. Natl. Acad. Sci. USA 100, 9826-9830 (2003).
[CrossRef]

J. X. Cheng, A. Volkmer, and X. S. Xie, "Theoretical and experimental characterization of coherent anti-Stokes Raman scattering microscopy," J. Opt. Soc. Am. B 19,1363-1375 (2002).

A. Volkmer, J. X. Cheng, and X. S. Xie, "Vibrational imaging with high sensitivity via epi-detected coherent anti-Stokes Raman scattering microscopy," Phys. Rev. Lett. 87, 023901 (2001).
[CrossRef]

J. X. Cheng, A. Volkmer, L. D. Book, and X. S. Xie, "An epi-detected coherent anti-Stokes Raman scattering (E-CARS) microscope with high spectral resolution and high sensitivity," J. Phys. Chem. B 105, 1277-1280 (2001).
[CrossRef]

Côté, D.

C. L. Evans, E. O. Potma, M. Puoris'haag, D. Côté, C. P. Lin, and X. S. Xie, "Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy," Proc. Natl. Acad. Sci. USA 102, 16807-16812 (2005).
[CrossRef]

Cunningham, M. L.

M. L. Cunningham, J. S. Johnson, S. M. Giovanazzi, and M. J. Peak, "Photosensitized production of superoxide anion by monochromatic (290-405 nm) ultraviolet irradiation of NADH and NADPH coenzymes," Photochem. Photobiol. 42, 125-128 (1985).

Denk, W.

W. Denk, J. H. Strickler, and W. W. Webb, "Two-Photon Laser Scanning Fluorescence Microscopy," Science 248, 73-76 (1990).
[CrossRef]

Dudovich, N.

N. Dudovich, D. Oron, and Y. Silberberg, "Single-pulse coherently controlled nonlinear Raman spectroscopy and microscopy," Nature 418,512-514 (2002).
[CrossRef]

Duncan, M. D.

Evans, C. L.

C. L. Evans, E. O. Potma, M. Puoris'haag, D. Côté, C. P. Lin, and X. S. Xie, "Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy," Proc. Natl. Acad. Sci. USA 102, 16807-16812 (2005).
[CrossRef]

C. L. Evans, E. O. Potma, and X. S. Xie, "Coherent anti-Stokes Raman scattering spectral interferometry:determination of the real and imaginary components of nonlinear susceptibility χ(3) for vibrational microscopy," Opt. Lett. 29,2923-2925 (2004).
[CrossRef]

Fischer, P.

Fu, Y.

H. Wang, Y. Fu, P. Zickmund, R. Shi, and J. X. Cheng, "Coherent anti-Stokes Raman scattering imaging of live spinal tissues," Biophys. J. 89, 581-591 (2005).
[CrossRef]

H. Wang, Y. Fu, and J. X. Cheng, "Light-matter energy exchange in coherent Raman microscopy," Phys. Rev. A, submitted (2005).

Giovanazzi, S. M.

M. L. Cunningham, J. S. Johnson, S. M. Giovanazzi, and M. J. Peak, "Photosensitized production of superoxide anion by monochromatic (290-405 nm) ultraviolet irradiation of NADH and NADPH coenzymes," Photochem. Photobiol. 42, 125-128 (1985).

Gratton, E.

B. R. Masters, P. T. C. So, C. Buehler, N. Barry, J. D. Sutin, W. W. Mantulin, and E. Gratton, "Mitigating thermal mechanical damage potential during two-photon dermal imaging," J. Biomed. Opt. 9, 1265-1270 (2004).
[CrossRef]

Halbhuber, K.-J.

Hashimoto, M.

T. Ichimura, N. Hayazawa, M. Hashimoto, Y. Inouye, and S. Kawata, "Tip-enhanced coherent anti-Stokes Raman scattering for vibrational nanoimaging," Phys. Rev. Lett. 92,220801 (2004).
[CrossRef]

Hayazawa, N.

T. Ichimura, N. Hayazawa, M. Hashimoto, Y. Inouye, and S. Kawata, "Tip-enhanced coherent anti-Stokes Raman scattering for vibrational nanoimaging," Phys. Rev. Lett. 92,220801 (2004).
[CrossRef]

Hell, S. W.

H. J. Koester, D. Baur, R. Uhl, and S. W. Hell, "Ca2+ fluorescence imaging with pico- and femtosecond two-photon excitation: signal and photodamge," Biophys. J. 77, 2226-2236 (1999).

Holtom, G. R.

A. Zumbusch, G. R. Holtom, and X. S. Xie, "Three-dimensional vibrational imaging by coherent anti-Stokes Raman scattering," Phys. Rev. Lett. 82, 4142-4145 (1999).
[CrossRef]

Hopt, A.

A. Hopt and E. Neher, "Highly nonlinear photodamage in two-photon fluorescence microscopy," Biophys. J. 80, 2029-2036 (2001).

Huettmann, G.

A. Vogel, J. Noack, G. Huettmann, and G. Paltauf, "Femtosecond-laser-produced low-density plasmas in transparent biological media: a tool for the creation of chemical, thermal, and thermomechanical effects below the optical breakdown threshold," Proc. SPIE 4633A,1-15 (2002).

Ichimura, T.

T. Ichimura, N. Hayazawa, M. Hashimoto, Y. Inouye, and S. Kawata, "Tip-enhanced coherent anti-Stokes Raman scattering for vibrational nanoimaging," Phys. Rev. Lett. 92,220801 (2004).
[CrossRef]

Inouye, Y.

T. Ichimura, N. Hayazawa, M. Hashimoto, Y. Inouye, and S. Kawata, "Tip-enhanced coherent anti-Stokes Raman scattering for vibrational nanoimaging," Phys. Rev. Lett. 92,220801 (2004).
[CrossRef]

Johnson, J. C.

K. P. Knutsen, J. C. Johnson, A. E. Miller, P. B. Petersen, and R. J. Saykally, "High spectral resolution multiplex CARS spectroscopy using chirped pulses," Chem. Phys. Lett. 387,436-441 (2004).
[CrossRef]

Johnson, J. S.

M. L. Cunningham, J. S. Johnson, S. M. Giovanazzi, and M. J. Peak, "Photosensitized production of superoxide anion by monochromatic (290-405 nm) ultraviolet irradiation of NADH and NADPH coenzymes," Photochem. Photobiol. 42, 125-128 (1985).

Kawata, S.

T. Ichimura, N. Hayazawa, M. Hashimoto, Y. Inouye, and S. Kawata, "Tip-enhanced coherent anti-Stokes Raman scattering for vibrational nanoimaging," Phys. Rev. Lett. 92,220801 (2004).
[CrossRef]

Kennedy, A. P.

A. P. Kennedy, J. Sutcliffe, and J. X. Cheng, "Molecular composition and orientation of myelin figures characterized by coherent anti-Stokes Raman scattering microscopy," Langmuir 21, 6478-6486 (2005).
[CrossRef]

Knutsen, K. P.

K. P. Knutsen, J. C. Johnson, A. E. Miller, P. B. Petersen, and R. J. Saykally, "High spectral resolution multiplex CARS spectroscopy using chirped pulses," Chem. Phys. Lett. 387,436-441 (2004).
[CrossRef]

Koester, H. J.

H. J. Koester, D. Baur, R. Uhl, and S. W. Hell, "Ca2+ fluorescence imaging with pico- and femtosecond two-photon excitation: signal and photodamge," Biophys. J. 77, 2226-2236 (1999).

König, K.

Li, L.

L. Li, H. Wang, and J. X. Cheng, "Quantitative coherent anti-Stokes Raman scattering imaging of lipid distribution in co-existing domains," Biophys. J. 89,3480-3490 (2005).
[CrossRef]

Liang, H.

Lin, C. P.

C. L. Evans, E. O. Potma, M. Puoris'haag, D. Côté, C. P. Lin, and X. S. Xie, "Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy," Proc. Natl. Acad. Sci. USA 102, 16807-16812 (2005).
[CrossRef]

Liou, G. F.

K. C. Neuman, E. H. Chadd, G. F. Liou, K. Bergman, and S. M. Block, "Characterization of photodamage to Escherichia coli in optical traps," Biophys. J. 77, 2856-2863 (1999).

Liu, Y.

Y. Liu, G. J. Sonek, M. W. Berns, and B. J. Tromberg, "Physiological monitoring of optically trapped cells: assessing the effects of confinement by 1064-nm laser tweezers using microfluorometry," Biophys. J. 71, 2158-2167 (1996).

Loew, L. M.

P. J. Campagnola and L. M. Loew, "Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms," Nat. Biotech. 21, 1356-1360 (2003).
[CrossRef]

Maker, P. D.

P. D. Maker and R. W. Terhune, "Study of Optical effects Due to an Induced Polarization Third Order in the Electric Field Strength," Phys. Rev. 137,A801-818 (1965).
[CrossRef]

Mantulin, W. W.

B. R. Masters, P. T. C. So, C. Buehler, N. Barry, J. D. Sutin, W. W. Mantulin, and E. Gratton, "Mitigating thermal mechanical damage potential during two-photon dermal imaging," J. Biomed. Opt. 9, 1265-1270 (2004).
[CrossRef]

Manuccia, T. J.

Marks, D. L.

Masters, B. R.

B. R. Masters, P. T. C. So, C. Buehler, N. Barry, J. D. Sutin, W. W. Mantulin, and E. Gratton, "Mitigating thermal mechanical damage potential during two-photon dermal imaging," J. Biomed. Opt. 9, 1265-1270 (2004).
[CrossRef]

Mertz, J.

Miller, A. E.

K. P. Knutsen, J. C. Johnson, A. E. Miller, P. B. Petersen, and R. J. Saykally, "High spectral resolution multiplex CARS spectroscopy using chirped pulses," Chem. Phys. Lett. 387,436-441 (2004).
[CrossRef]

Moreaux, L.

Müller, M.

G. W. H. Wurpel, H. A. Rinia, and M. Müller, "Imaging orientational order and lipid density in multilamellar vesicles with multiplex CARS microscopy," J. Microsc. 218,37-45 (2005).
[CrossRef]

G. W. H. Wurpel, J. M. Schins, and M. Müller, "Chemical specificity in three-dimensional imaging with multiplex coherent anti-Stokes Raman scattering microscopy," Opt. Lett. 27, 1093-1095 (2002).

Nan, X.

X. Nan, J. X. Cheng, and X. S. Xie, "Vibrational imaging of lipid droplets in live fibroblast cells using coherent anti-Stokes Raman microscopy," J. Lipid Res. 40,2202-2208 (2003).

Neher, E.

A. Hopt and E. Neher, "Highly nonlinear photodamage in two-photon fluorescence microscopy," Biophys. J. 80, 2029-2036 (2001).

Neuman, K. C.

K. C. Neuman, E. H. Chadd, G. F. Liou, K. Bergman, and S. M. Block, "Characterization of photodamage to Escherichia coli in optical traps," Biophys. J. 77, 2856-2863 (1999).

Noack, J.

A. Vogel, J. Noack, G. Huettmann, and G. Paltauf, "Femtosecond-laser-produced low-density plasmas in transparent biological media: a tool for the creation of chemical, thermal, and thermomechanical effects below the optical breakdown threshold," Proc. SPIE 4633A,1-15 (2002).

Oron, D.

N. Dudovich, D. Oron, and Y. Silberberg, "Single-pulse coherently controlled nonlinear Raman spectroscopy and microscopy," Nature 418,512-514 (2002).
[CrossRef]

Paltauf, G.

A. Vogel, J. Noack, G. Huettmann, and G. Paltauf, "Femtosecond-laser-produced low-density plasmas in transparent biological media: a tool for the creation of chemical, thermal, and thermomechanical effects below the optical breakdown threshold," Proc. SPIE 4633A,1-15 (2002).

Pautot, S.

J. X. Cheng, S. Pautot, D. A. Weitz, and X. S. Xie, "Ordering of water molecules between phospholipid bilayers visualized by coherent anti-Stokes Raman scattering microscopy," Proc. Natl. Acad. Sci. USA 100, 9826-9830 (2003).
[CrossRef]

Peak, M. J.

M. L. Cunningham, J. S. Johnson, S. M. Giovanazzi, and M. J. Peak, "Photosensitized production of superoxide anion by monochromatic (290-405 nm) ultraviolet irradiation of NADH and NADPH coenzymes," Photochem. Photobiol. 42, 125-128 (1985).

Petersen, P. B.

K. P. Knutsen, J. C. Johnson, A. E. Miller, P. B. Petersen, and R. J. Saykally, "High spectral resolution multiplex CARS spectroscopy using chirped pulses," Chem. Phys. Lett. 387,436-441 (2004).
[CrossRef]

Potma, E. O.

E. O. Potma and X. S. Xie, "Direct visualization of lipid phase segregation in single lipid bilayers with coherent anti-Stokes Raman scattering microscopy," Chem. Phys. Chem. 6, 77-79 (2005).

C. L. Evans, E. O. Potma, M. Puoris'haag, D. Côté, C. P. Lin, and X. S. Xie, "Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy," Proc. Natl. Acad. Sci. USA 102, 16807-16812 (2005).
[CrossRef]

C. L. Evans, E. O. Potma, and X. S. Xie, "Coherent anti-Stokes Raman scattering spectral interferometry:determination of the real and imaginary components of nonlinear susceptibility χ(3) for vibrational microscopy," Opt. Lett. 29,2923-2925 (2004).
[CrossRef]

E. O. Potma, W. P. D. Boeij, P. J. M. v. Haastert, and D. A. Wiersma, "Real-time visualization of intracellular hydrodynamics in single living cells," Proc. Natl. Acad. Sci. USA 98,1577-1582 (2001).
[CrossRef]

Puoris'haag, M.

C. L. Evans, E. O. Potma, M. Puoris'haag, D. Côté, C. P. Lin, and X. S. Xie, "Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy," Proc. Natl. Acad. Sci. USA 102, 16807-16812 (2005).
[CrossRef]

Reintjes, J.

Riemann, I.

Rinia, H. A.

G. W. H. Wurpel, H. A. Rinia, and M. Müller, "Imaging orientational order and lipid density in multilamellar vesicles with multiplex CARS microscopy," J. Microsc. 218,37-45 (2005).
[CrossRef]

Sandre, O.

Saykally, R. J.

K. P. Knutsen, J. C. Johnson, A. E. Miller, P. B. Petersen, and R. J. Saykally, "High spectral resolution multiplex CARS spectroscopy using chirped pulses," Chem. Phys. Lett. 387,436-441 (2004).
[CrossRef]

Schins, J. M.

Shear, J. B.

C. Xu, W. Zipfel, J. B. Shear, R. M. Williams, and W. W. Webb, "Multiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy," Proc. Natl. Acad. Sci. USA 93, 10763-10768 (1996).
[CrossRef]

Shi, R.

H. Wang, Y. Fu, P. Zickmund, R. Shi, and J. X. Cheng, "Coherent anti-Stokes Raman scattering imaging of live spinal tissues," Biophys. J. 89, 581-591 (2005).
[CrossRef]

Silberberg, Y.

N. Dudovich, D. Oron, and Y. Silberberg, "Single-pulse coherently controlled nonlinear Raman spectroscopy and microscopy," Nature 418,512-514 (2002).
[CrossRef]

So, P. T. C.

B. R. Masters, P. T. C. So, C. Buehler, N. Barry, J. D. Sutin, W. W. Mantulin, and E. Gratton, "Mitigating thermal mechanical damage potential during two-photon dermal imaging," J. Biomed. Opt. 9, 1265-1270 (2004).
[CrossRef]

Sonek, G. J.

Y. Liu, G. J. Sonek, M. W. Berns, and B. J. Tromberg, "Physiological monitoring of optically trapped cells: assessing the effects of confinement by 1064-nm laser tweezers using microfluorometry," Biophys. J. 71, 2158-2167 (1996).

Strickler, J. H.

W. Denk, J. H. Strickler, and W. W. Webb, "Two-Photon Laser Scanning Fluorescence Microscopy," Science 248, 73-76 (1990).
[CrossRef]

Sutcliffe, J.

A. P. Kennedy, J. Sutcliffe, and J. X. Cheng, "Molecular composition and orientation of myelin figures characterized by coherent anti-Stokes Raman scattering microscopy," Langmuir 21, 6478-6486 (2005).
[CrossRef]

Sutin, J. D.

B. R. Masters, P. T. C. So, C. Buehler, N. Barry, J. D. Sutin, W. W. Mantulin, and E. Gratton, "Mitigating thermal mechanical damage potential during two-photon dermal imaging," J. Biomed. Opt. 9, 1265-1270 (2004).
[CrossRef]

Terhune, R. W.

P. D. Maker and R. W. Terhune, "Study of Optical effects Due to an Induced Polarization Third Order in the Electric Field Strength," Phys. Rev. 137,A801-818 (1965).
[CrossRef]

Tromberg, B. J.

K. König, H. Liang, M. W. Berns, and B. J. Tromberg, "Cell damage in near-infrared multimode optical traps as a result of multiphoton absorption," Opt. Lett. 21, 1090-1092 (1996).

Y. Liu, G. J. Sonek, M. W. Berns, and B. J. Tromberg, "Physiological monitoring of optically trapped cells: assessing the effects of confinement by 1064-nm laser tweezers using microfluorometry," Biophys. J. 71, 2158-2167 (1996).

Uhl, R.

H. J. Koester, D. Baur, R. Uhl, and S. W. Hell, "Ca2+ fluorescence imaging with pico- and femtosecond two-photon excitation: signal and photodamge," Biophys. J. 77, 2226-2236 (1999).

Vinegoni, C.

Vogel, A.

A. Vogel, J. Noack, G. Huettmann, and G. Paltauf, "Femtosecond-laser-produced low-density plasmas in transparent biological media: a tool for the creation of chemical, thermal, and thermomechanical effects below the optical breakdown threshold," Proc. SPIE 4633A,1-15 (2002).

Volkmer, A.

J. X. Cheng, A. Volkmer, and X. S. Xie, "Theoretical and experimental characterization of coherent anti-Stokes Raman scattering microscopy," J. Opt. Soc. Am. B 19,1363-1375 (2002).

A. Volkmer, J. X. Cheng, and X. S. Xie, "Vibrational imaging with high sensitivity via epi-detected coherent anti-Stokes Raman scattering microscopy," Phys. Rev. Lett. 87, 023901 (2001).
[CrossRef]

J. X. Cheng, A. Volkmer, L. D. Book, and X. S. Xie, "An epi-detected coherent anti-Stokes Raman scattering (E-CARS) microscope with high spectral resolution and high sensitivity," J. Phys. Chem. B 105, 1277-1280 (2001).
[CrossRef]

Wang, H.

L. Li, H. Wang, and J. X. Cheng, "Quantitative coherent anti-Stokes Raman scattering imaging of lipid distribution in co-existing domains," Biophys. J. 89,3480-3490 (2005).
[CrossRef]

H. Wang, Y. Fu, and J. X. Cheng, "Light-matter energy exchange in coherent Raman microscopy," Phys. Rev. A, submitted (2005).

H. Wang, Y. Fu, P. Zickmund, R. Shi, and J. X. Cheng, "Coherent anti-Stokes Raman scattering imaging of live spinal tissues," Biophys. J. 89, 581-591 (2005).
[CrossRef]

Webb, W. W.

C. Xu, W. Zipfel, J. B. Shear, R. M. Williams, and W. W. Webb, "Multiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy," Proc. Natl. Acad. Sci. USA 93, 10763-10768 (1996).
[CrossRef]

W. Denk, J. H. Strickler, and W. W. Webb, "Two-Photon Laser Scanning Fluorescence Microscopy," Science 248, 73-76 (1990).
[CrossRef]

Weitz, D. A.

J. X. Cheng, S. Pautot, D. A. Weitz, and X. S. Xie, "Ordering of water molecules between phospholipid bilayers visualized by coherent anti-Stokes Raman scattering microscopy," Proc. Natl. Acad. Sci. USA 100, 9826-9830 (2003).
[CrossRef]

Williams, R. M.

C. Xu, W. Zipfel, J. B. Shear, R. M. Williams, and W. W. Webb, "Multiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy," Proc. Natl. Acad. Sci. USA 93, 10763-10768 (1996).
[CrossRef]

Wurpel, G. W. H.

G. W. H. Wurpel, H. A. Rinia, and M. Müller, "Imaging orientational order and lipid density in multilamellar vesicles with multiplex CARS microscopy," J. Microsc. 218,37-45 (2005).
[CrossRef]

G. W. H. Wurpel, J. M. Schins, and M. Müller, "Chemical specificity in three-dimensional imaging with multiplex coherent anti-Stokes Raman scattering microscopy," Opt. Lett. 27, 1093-1095 (2002).

Xie, X. S.

E. O. Potma and X. S. Xie, "Direct visualization of lipid phase segregation in single lipid bilayers with coherent anti-Stokes Raman scattering microscopy," Chem. Phys. Chem. 6, 77-79 (2005).

C. L. Evans, E. O. Potma, M. Puoris'haag, D. Côté, C. P. Lin, and X. S. Xie, "Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy," Proc. Natl. Acad. Sci. USA 102, 16807-16812 (2005).
[CrossRef]

C. L. Evans, E. O. Potma, and X. S. Xie, "Coherent anti-Stokes Raman scattering spectral interferometry:determination of the real and imaginary components of nonlinear susceptibility χ(3) for vibrational microscopy," Opt. Lett. 29,2923-2925 (2004).
[CrossRef]

J. X. Cheng and X. S. Xie, "Coherent anti-Stokes Raman scattering microscopy: instrumentation, theory, and applications," J. Phys. Chem. B 108, 827-840 (2004).
[CrossRef]

X. Nan, J. X. Cheng, and X. S. Xie, "Vibrational imaging of lipid droplets in live fibroblast cells using coherent anti-Stokes Raman microscopy," J. Lipid Res. 40,2202-2208 (2003).

J. X. Cheng, S. Pautot, D. A. Weitz, and X. S. Xie, "Ordering of water molecules between phospholipid bilayers visualized by coherent anti-Stokes Raman scattering microscopy," Proc. Natl. Acad. Sci. USA 100, 9826-9830 (2003).
[CrossRef]

J. X. Cheng, A. Volkmer, and X. S. Xie, "Theoretical and experimental characterization of coherent anti-Stokes Raman scattering microscopy," J. Opt. Soc. Am. B 19,1363-1375 (2002).

A. Volkmer, J. X. Cheng, and X. S. Xie, "Vibrational imaging with high sensitivity via epi-detected coherent anti-Stokes Raman scattering microscopy," Phys. Rev. Lett. 87, 023901 (2001).
[CrossRef]

J. X. Cheng, A. Volkmer, L. D. Book, and X. S. Xie, "An epi-detected coherent anti-Stokes Raman scattering (E-CARS) microscope with high spectral resolution and high sensitivity," J. Phys. Chem. B 105, 1277-1280 (2001).
[CrossRef]

A. Zumbusch, G. R. Holtom, and X. S. Xie, "Three-dimensional vibrational imaging by coherent anti-Stokes Raman scattering," Phys. Rev. Lett. 82, 4142-4145 (1999).
[CrossRef]

Xu, C.

C. Xu, W. Zipfel, J. B. Shear, R. M. Williams, and W. W. Webb, "Multiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy," Proc. Natl. Acad. Sci. USA 93, 10763-10768 (1996).
[CrossRef]

Zickmund, P.

H. Wang, Y. Fu, P. Zickmund, R. Shi, and J. X. Cheng, "Coherent anti-Stokes Raman scattering imaging of live spinal tissues," Biophys. J. 89, 581-591 (2005).
[CrossRef]

Zipfel, W.

C. Xu, W. Zipfel, J. B. Shear, R. M. Williams, and W. W. Webb, "Multiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy," Proc. Natl. Acad. Sci. USA 93, 10763-10768 (1996).
[CrossRef]

Zumbusch, A.

A. Zumbusch, G. R. Holtom, and X. S. Xie, "Three-dimensional vibrational imaging by coherent anti-Stokes Raman scattering," Phys. Rev. Lett. 82, 4142-4145 (1999).
[CrossRef]

Biophys. J.

L. Li, H. Wang, and J. X. Cheng, "Quantitative coherent anti-Stokes Raman scattering imaging of lipid distribution in co-existing domains," Biophys. J. 89,3480-3490 (2005).
[CrossRef]

A. Hopt and E. Neher, "Highly nonlinear photodamage in two-photon fluorescence microscopy," Biophys. J. 80, 2029-2036 (2001).

H. J. Koester, D. Baur, R. Uhl, and S. W. Hell, "Ca2+ fluorescence imaging with pico- and femtosecond two-photon excitation: signal and photodamge," Biophys. J. 77, 2226-2236 (1999).

H. Wang, Y. Fu, P. Zickmund, R. Shi, and J. X. Cheng, "Coherent anti-Stokes Raman scattering imaging of live spinal tissues," Biophys. J. 89, 581-591 (2005).
[CrossRef]

K. C. Neuman, E. H. Chadd, G. F. Liou, K. Bergman, and S. M. Block, "Characterization of photodamage to Escherichia coli in optical traps," Biophys. J. 77, 2856-2863 (1999).

Y. Liu, G. J. Sonek, M. W. Berns, and B. J. Tromberg, "Physiological monitoring of optically trapped cells: assessing the effects of confinement by 1064-nm laser tweezers using microfluorometry," Biophys. J. 71, 2158-2167 (1996).

Chem. Phys. Chem.

E. O. Potma and X. S. Xie, "Direct visualization of lipid phase segregation in single lipid bilayers with coherent anti-Stokes Raman scattering microscopy," Chem. Phys. Chem. 6, 77-79 (2005).

Chem. Phys. Lett.

K. P. Knutsen, J. C. Johnson, A. E. Miller, P. B. Petersen, and R. J. Saykally, "High spectral resolution multiplex CARS spectroscopy using chirped pulses," Chem. Phys. Lett. 387,436-441 (2004).
[CrossRef]

Histochem. Cell Biol.

K. König, "Laser tweezers and multiphoton microscopes in life sciences," Histochem. Cell Biol. 114, 79-92 (2000).

J. Biomed. Opt.

B. R. Masters, P. T. C. So, C. Buehler, N. Barry, J. D. Sutin, W. W. Mantulin, and E. Gratton, "Mitigating thermal mechanical damage potential during two-photon dermal imaging," J. Biomed. Opt. 9, 1265-1270 (2004).
[CrossRef]

J. Lipid Res.

X. Nan, J. X. Cheng, and X. S. Xie, "Vibrational imaging of lipid droplets in live fibroblast cells using coherent anti-Stokes Raman microscopy," J. Lipid Res. 40,2202-2208 (2003).

J. Microsc.

G. W. H. Wurpel, H. A. Rinia, and M. Müller, "Imaging orientational order and lipid density in multilamellar vesicles with multiplex CARS microscopy," J. Microsc. 218,37-45 (2005).
[CrossRef]

J. Opt. Soc. Am. B

J. Phys. Chem. B

J. X. Cheng and X. S. Xie, "Coherent anti-Stokes Raman scattering microscopy: instrumentation, theory, and applications," J. Phys. Chem. B 108, 827-840 (2004).
[CrossRef]

J. X. Cheng, A. Volkmer, L. D. Book, and X. S. Xie, "An epi-detected coherent anti-Stokes Raman scattering (E-CARS) microscope with high spectral resolution and high sensitivity," J. Phys. Chem. B 105, 1277-1280 (2001).
[CrossRef]

Langmuir

A. P. Kennedy, J. Sutcliffe, and J. X. Cheng, "Molecular composition and orientation of myelin figures characterized by coherent anti-Stokes Raman scattering microscopy," Langmuir 21, 6478-6486 (2005).
[CrossRef]

Nat. Biotech.

P. J. Campagnola and L. M. Loew, "Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms," Nat. Biotech. 21, 1356-1360 (2003).
[CrossRef]

Nature

N. Dudovich, D. Oron, and Y. Silberberg, "Single-pulse coherently controlled nonlinear Raman spectroscopy and microscopy," Nature 418,512-514 (2002).
[CrossRef]

Opt. Lett.

Photochem. Photobiol.

M. L. Cunningham, J. S. Johnson, S. M. Giovanazzi, and M. J. Peak, "Photosensitized production of superoxide anion by monochromatic (290-405 nm) ultraviolet irradiation of NADH and NADPH coenzymes," Photochem. Photobiol. 42, 125-128 (1985).

Phys. Rev.

P. D. Maker and R. W. Terhune, "Study of Optical effects Due to an Induced Polarization Third Order in the Electric Field Strength," Phys. Rev. 137,A801-818 (1965).
[CrossRef]

Phys. Rev. A

H. Wang, Y. Fu, and J. X. Cheng, "Light-matter energy exchange in coherent Raman microscopy," Phys. Rev. A, submitted (2005).

Phys. Rev. Lett.

T. Ichimura, N. Hayazawa, M. Hashimoto, Y. Inouye, and S. Kawata, "Tip-enhanced coherent anti-Stokes Raman scattering for vibrational nanoimaging," Phys. Rev. Lett. 92,220801 (2004).
[CrossRef]

A. Volkmer, J. X. Cheng, and X. S. Xie, "Vibrational imaging with high sensitivity via epi-detected coherent anti-Stokes Raman scattering microscopy," Phys. Rev. Lett. 87, 023901 (2001).
[CrossRef]

A. Zumbusch, G. R. Holtom, and X. S. Xie, "Three-dimensional vibrational imaging by coherent anti-Stokes Raman scattering," Phys. Rev. Lett. 82, 4142-4145 (1999).
[CrossRef]

Proc. Natl. Acad. Sci. USA

C. Xu, W. Zipfel, J. B. Shear, R. M. Williams, and W. W. Webb, "Multiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy," Proc. Natl. Acad. Sci. USA 93, 10763-10768 (1996).
[CrossRef]

C. L. Evans, E. O. Potma, M. Puoris'haag, D. Côté, C. P. Lin, and X. S. Xie, "Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy," Proc. Natl. Acad. Sci. USA 102, 16807-16812 (2005).
[CrossRef]

J. X. Cheng, S. Pautot, D. A. Weitz, and X. S. Xie, "Ordering of water molecules between phospholipid bilayers visualized by coherent anti-Stokes Raman scattering microscopy," Proc. Natl. Acad. Sci. USA 100, 9826-9830 (2003).
[CrossRef]

E. O. Potma, W. P. D. Boeij, P. J. M. v. Haastert, and D. A. Wiersma, "Real-time visualization of intracellular hydrodynamics in single living cells," Proc. Natl. Acad. Sci. USA 98,1577-1582 (2001).
[CrossRef]

Proc. SPIE

A. Vogel, J. Noack, G. Huettmann, and G. Paltauf, "Femtosecond-laser-produced low-density plasmas in transparent biological media: a tool for the creation of chemical, thermal, and thermomechanical effects below the optical breakdown threshold," Proc. SPIE 4633A,1-15 (2002).

Science

W. Denk, J. H. Strickler, and W. W. Webb, "Two-Photon Laser Scanning Fluorescence Microscopy," Science 248, 73-76 (1990).
[CrossRef]

Other

Y. R. Shen, The Principles of Nonlinear Optics (John Wiley and Sons Inc., New York, 1984).

J. S. Gomez, "Coherent Raman Spectroscopy," in Modern Techniques in Raman Spectroscopy, J. J. Laserna, editor. (John Wiley & Sons Inc., New York, 1996).

P. Morell and R. H. Quarles, "Myelin formation, structure, and biochemistry," in Basic Neurochemistry: Molecular, Cellular, and Medical Aspects, G. J. Siegel, B. W. Agranoff, R. W. Alberts, and P. B. Molinoff, eds. (Lippincott Williams & Wilkins, Philadelphia, 1999).

P. N. Prasad, Introduction to biophotonics. (Wiley Interscience, Hoboken, NJ, 2003), pp. 168-175.

J. Diels and W. Rudolph, "Generation of extreme wavelengths," in Ultrashort laser pulse phenomena: fundamentals, techniques, and applications on a femtosecond time scale. (Academic Press, San Diego, 1996), pp. 472-475.

H. R. Griem, "Optical radiation," in Plasma physics in theory and application, W. B. Kunkel, editor. (McGraw-Hill, Inc., New York, 1966), pp. 278-280.

Cited By

OSA participates in CrossRef's Cited-By Linking service. Citing articles from OSA journals and other participating publishers are listed here.

Alert me when this article is cited.


Metrics