Abstract

The comparison of various operational modes of optically pumped magnetometers in [V. Schultze et al., Opt. Express 20, 14201 (2012)] used some incorrectly cited data. A corrected table of magnetometer parameters is given.

© 2012 OSA

Full Article  |  PDF Article

References

  • View by:
  • |
  • |
  • |

  1. V. Schultze, R. Ijsselsteijn, T. Scholtes, S. Woetzel, and H.-G. Meyer, “Characteristics and performance of an intensity-modulated optically pumped magnetometer in comparison to the classical M(x) magnetometer,” Opt. Express20(13), 14201–14212 (2012).
    [CrossRef] [PubMed]
  2. T. Scholtes, V. Schultze, R. IJsselsteijn, S. Woetzel, and H.-G. Meyer, “Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell,” Phys. Rev. A84(4), 043416 (2011).
    [CrossRef]
  3. T. Scholtes, V. Schultze, R. IJsselsteijn, S. Woetzel, and H.-G. Meyer, “Erratum: Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell [Phys. Rev. A 84, 043416 (2011)],” Phys. Rev. A86(5), 059904 (2012).
    [CrossRef]
  4. E. B. Aleksandrov, M. V. Balabas, A. K. Vershovskii, A. E. Ivanov, N. N. Yakobson, V. L. Velichanskii, and N. V. Senkov, “Laser Pumping in the Scheme of an Mx-Magnetometer,” Opt. Spectrosc.78, 292–298 (1995).
  5. N. Castagna, G. Bison, G. Domenico, A. Hofer, P. Knowles, C. Macchione, H. Saudan, and A. Weis, “A large sample study of spin relaxation and magnetometric sensitivity of paraffin-coated Cs vapor cells,” Appl. Phys. B96(4), 763–772 (2009).
    [CrossRef]
  6. P. D. D. Schwindt, B. Lindseth, S. Knappe, V. Shah, J. Kitching, and L.-A. Liew, “Chip-scale atomic magnetometer with improved sensitivity by use of the Mx technique,” Appl. Phys. Lett.90(8), 081102 (2007).
    [CrossRef]
  7. R. Jimenez-Martinez, W. C. Griffith, Y.-J. Wang, S. Knappe, J. Kitching, K. Smith, and M. Prouty, “Sensitivity Comparison of Mx and Frequency-Modulated Bell-Bloom Cs Magnetometers in a Microfabricated Cell,” IEEE Trans. Instrum. Meas.59(2), 372–378 (2010).
    [CrossRef]

2012

V. Schultze, R. Ijsselsteijn, T. Scholtes, S. Woetzel, and H.-G. Meyer, “Characteristics and performance of an intensity-modulated optically pumped magnetometer in comparison to the classical M(x) magnetometer,” Opt. Express20(13), 14201–14212 (2012).
[CrossRef] [PubMed]

T. Scholtes, V. Schultze, R. IJsselsteijn, S. Woetzel, and H.-G. Meyer, “Erratum: Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell [Phys. Rev. A 84, 043416 (2011)],” Phys. Rev. A86(5), 059904 (2012).
[CrossRef]

2011

T. Scholtes, V. Schultze, R. IJsselsteijn, S. Woetzel, and H.-G. Meyer, “Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell,” Phys. Rev. A84(4), 043416 (2011).
[CrossRef]

2010

R. Jimenez-Martinez, W. C. Griffith, Y.-J. Wang, S. Knappe, J. Kitching, K. Smith, and M. Prouty, “Sensitivity Comparison of Mx and Frequency-Modulated Bell-Bloom Cs Magnetometers in a Microfabricated Cell,” IEEE Trans. Instrum. Meas.59(2), 372–378 (2010).
[CrossRef]

2009

N. Castagna, G. Bison, G. Domenico, A. Hofer, P. Knowles, C. Macchione, H. Saudan, and A. Weis, “A large sample study of spin relaxation and magnetometric sensitivity of paraffin-coated Cs vapor cells,” Appl. Phys. B96(4), 763–772 (2009).
[CrossRef]

2007

P. D. D. Schwindt, B. Lindseth, S. Knappe, V. Shah, J. Kitching, and L.-A. Liew, “Chip-scale atomic magnetometer with improved sensitivity by use of the Mx technique,” Appl. Phys. Lett.90(8), 081102 (2007).
[CrossRef]

1995

E. B. Aleksandrov, M. V. Balabas, A. K. Vershovskii, A. E. Ivanov, N. N. Yakobson, V. L. Velichanskii, and N. V. Senkov, “Laser Pumping in the Scheme of an Mx-Magnetometer,” Opt. Spectrosc.78, 292–298 (1995).

Aleksandrov, E. B.

E. B. Aleksandrov, M. V. Balabas, A. K. Vershovskii, A. E. Ivanov, N. N. Yakobson, V. L. Velichanskii, and N. V. Senkov, “Laser Pumping in the Scheme of an Mx-Magnetometer,” Opt. Spectrosc.78, 292–298 (1995).

Balabas, M. V.

E. B. Aleksandrov, M. V. Balabas, A. K. Vershovskii, A. E. Ivanov, N. N. Yakobson, V. L. Velichanskii, and N. V. Senkov, “Laser Pumping in the Scheme of an Mx-Magnetometer,” Opt. Spectrosc.78, 292–298 (1995).

Bison, G.

N. Castagna, G. Bison, G. Domenico, A. Hofer, P. Knowles, C. Macchione, H. Saudan, and A. Weis, “A large sample study of spin relaxation and magnetometric sensitivity of paraffin-coated Cs vapor cells,” Appl. Phys. B96(4), 763–772 (2009).
[CrossRef]

Castagna, N.

N. Castagna, G. Bison, G. Domenico, A. Hofer, P. Knowles, C. Macchione, H. Saudan, and A. Weis, “A large sample study of spin relaxation and magnetometric sensitivity of paraffin-coated Cs vapor cells,” Appl. Phys. B96(4), 763–772 (2009).
[CrossRef]

Domenico, G.

N. Castagna, G. Bison, G. Domenico, A. Hofer, P. Knowles, C. Macchione, H. Saudan, and A. Weis, “A large sample study of spin relaxation and magnetometric sensitivity of paraffin-coated Cs vapor cells,” Appl. Phys. B96(4), 763–772 (2009).
[CrossRef]

Griffith, W. C.

R. Jimenez-Martinez, W. C. Griffith, Y.-J. Wang, S. Knappe, J. Kitching, K. Smith, and M. Prouty, “Sensitivity Comparison of Mx and Frequency-Modulated Bell-Bloom Cs Magnetometers in a Microfabricated Cell,” IEEE Trans. Instrum. Meas.59(2), 372–378 (2010).
[CrossRef]

Hofer, A.

N. Castagna, G. Bison, G. Domenico, A. Hofer, P. Knowles, C. Macchione, H. Saudan, and A. Weis, “A large sample study of spin relaxation and magnetometric sensitivity of paraffin-coated Cs vapor cells,” Appl. Phys. B96(4), 763–772 (2009).
[CrossRef]

IJsselsteijn, R.

T. Scholtes, V. Schultze, R. IJsselsteijn, S. Woetzel, and H.-G. Meyer, “Erratum: Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell [Phys. Rev. A 84, 043416 (2011)],” Phys. Rev. A86(5), 059904 (2012).
[CrossRef]

V. Schultze, R. Ijsselsteijn, T. Scholtes, S. Woetzel, and H.-G. Meyer, “Characteristics and performance of an intensity-modulated optically pumped magnetometer in comparison to the classical M(x) magnetometer,” Opt. Express20(13), 14201–14212 (2012).
[CrossRef] [PubMed]

T. Scholtes, V. Schultze, R. IJsselsteijn, S. Woetzel, and H.-G. Meyer, “Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell,” Phys. Rev. A84(4), 043416 (2011).
[CrossRef]

Ivanov, A. E.

E. B. Aleksandrov, M. V. Balabas, A. K. Vershovskii, A. E. Ivanov, N. N. Yakobson, V. L. Velichanskii, and N. V. Senkov, “Laser Pumping in the Scheme of an Mx-Magnetometer,” Opt. Spectrosc.78, 292–298 (1995).

Jimenez-Martinez, R.

R. Jimenez-Martinez, W. C. Griffith, Y.-J. Wang, S. Knappe, J. Kitching, K. Smith, and M. Prouty, “Sensitivity Comparison of Mx and Frequency-Modulated Bell-Bloom Cs Magnetometers in a Microfabricated Cell,” IEEE Trans. Instrum. Meas.59(2), 372–378 (2010).
[CrossRef]

Kitching, J.

R. Jimenez-Martinez, W. C. Griffith, Y.-J. Wang, S. Knappe, J. Kitching, K. Smith, and M. Prouty, “Sensitivity Comparison of Mx and Frequency-Modulated Bell-Bloom Cs Magnetometers in a Microfabricated Cell,” IEEE Trans. Instrum. Meas.59(2), 372–378 (2010).
[CrossRef]

P. D. D. Schwindt, B. Lindseth, S. Knappe, V. Shah, J. Kitching, and L.-A. Liew, “Chip-scale atomic magnetometer with improved sensitivity by use of the Mx technique,” Appl. Phys. Lett.90(8), 081102 (2007).
[CrossRef]

Knappe, S.

R. Jimenez-Martinez, W. C. Griffith, Y.-J. Wang, S. Knappe, J. Kitching, K. Smith, and M. Prouty, “Sensitivity Comparison of Mx and Frequency-Modulated Bell-Bloom Cs Magnetometers in a Microfabricated Cell,” IEEE Trans. Instrum. Meas.59(2), 372–378 (2010).
[CrossRef]

P. D. D. Schwindt, B. Lindseth, S. Knappe, V. Shah, J. Kitching, and L.-A. Liew, “Chip-scale atomic magnetometer with improved sensitivity by use of the Mx technique,” Appl. Phys. Lett.90(8), 081102 (2007).
[CrossRef]

Knowles, P.

N. Castagna, G. Bison, G. Domenico, A. Hofer, P. Knowles, C. Macchione, H. Saudan, and A. Weis, “A large sample study of spin relaxation and magnetometric sensitivity of paraffin-coated Cs vapor cells,” Appl. Phys. B96(4), 763–772 (2009).
[CrossRef]

Liew, L.-A.

P. D. D. Schwindt, B. Lindseth, S. Knappe, V. Shah, J. Kitching, and L.-A. Liew, “Chip-scale atomic magnetometer with improved sensitivity by use of the Mx technique,” Appl. Phys. Lett.90(8), 081102 (2007).
[CrossRef]

Lindseth, B.

P. D. D. Schwindt, B. Lindseth, S. Knappe, V. Shah, J. Kitching, and L.-A. Liew, “Chip-scale atomic magnetometer with improved sensitivity by use of the Mx technique,” Appl. Phys. Lett.90(8), 081102 (2007).
[CrossRef]

Macchione, C.

N. Castagna, G. Bison, G. Domenico, A. Hofer, P. Knowles, C. Macchione, H. Saudan, and A. Weis, “A large sample study of spin relaxation and magnetometric sensitivity of paraffin-coated Cs vapor cells,” Appl. Phys. B96(4), 763–772 (2009).
[CrossRef]

Meyer, H.-G.

T. Scholtes, V. Schultze, R. IJsselsteijn, S. Woetzel, and H.-G. Meyer, “Erratum: Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell [Phys. Rev. A 84, 043416 (2011)],” Phys. Rev. A86(5), 059904 (2012).
[CrossRef]

V. Schultze, R. Ijsselsteijn, T. Scholtes, S. Woetzel, and H.-G. Meyer, “Characteristics and performance of an intensity-modulated optically pumped magnetometer in comparison to the classical M(x) magnetometer,” Opt. Express20(13), 14201–14212 (2012).
[CrossRef] [PubMed]

T. Scholtes, V. Schultze, R. IJsselsteijn, S. Woetzel, and H.-G. Meyer, “Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell,” Phys. Rev. A84(4), 043416 (2011).
[CrossRef]

Prouty, M.

R. Jimenez-Martinez, W. C. Griffith, Y.-J. Wang, S. Knappe, J. Kitching, K. Smith, and M. Prouty, “Sensitivity Comparison of Mx and Frequency-Modulated Bell-Bloom Cs Magnetometers in a Microfabricated Cell,” IEEE Trans. Instrum. Meas.59(2), 372–378 (2010).
[CrossRef]

Saudan, H.

N. Castagna, G. Bison, G. Domenico, A. Hofer, P. Knowles, C. Macchione, H. Saudan, and A. Weis, “A large sample study of spin relaxation and magnetometric sensitivity of paraffin-coated Cs vapor cells,” Appl. Phys. B96(4), 763–772 (2009).
[CrossRef]

Scholtes, T.

T. Scholtes, V. Schultze, R. IJsselsteijn, S. Woetzel, and H.-G. Meyer, “Erratum: Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell [Phys. Rev. A 84, 043416 (2011)],” Phys. Rev. A86(5), 059904 (2012).
[CrossRef]

V. Schultze, R. Ijsselsteijn, T. Scholtes, S. Woetzel, and H.-G. Meyer, “Characteristics and performance of an intensity-modulated optically pumped magnetometer in comparison to the classical M(x) magnetometer,” Opt. Express20(13), 14201–14212 (2012).
[CrossRef] [PubMed]

T. Scholtes, V. Schultze, R. IJsselsteijn, S. Woetzel, and H.-G. Meyer, “Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell,” Phys. Rev. A84(4), 043416 (2011).
[CrossRef]

Schultze, V.

V. Schultze, R. Ijsselsteijn, T. Scholtes, S. Woetzel, and H.-G. Meyer, “Characteristics and performance of an intensity-modulated optically pumped magnetometer in comparison to the classical M(x) magnetometer,” Opt. Express20(13), 14201–14212 (2012).
[CrossRef] [PubMed]

T. Scholtes, V. Schultze, R. IJsselsteijn, S. Woetzel, and H.-G. Meyer, “Erratum: Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell [Phys. Rev. A 84, 043416 (2011)],” Phys. Rev. A86(5), 059904 (2012).
[CrossRef]

T. Scholtes, V. Schultze, R. IJsselsteijn, S. Woetzel, and H.-G. Meyer, “Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell,” Phys. Rev. A84(4), 043416 (2011).
[CrossRef]

Schwindt, P. D. D.

P. D. D. Schwindt, B. Lindseth, S. Knappe, V. Shah, J. Kitching, and L.-A. Liew, “Chip-scale atomic magnetometer with improved sensitivity by use of the Mx technique,” Appl. Phys. Lett.90(8), 081102 (2007).
[CrossRef]

Senkov, N. V.

E. B. Aleksandrov, M. V. Balabas, A. K. Vershovskii, A. E. Ivanov, N. N. Yakobson, V. L. Velichanskii, and N. V. Senkov, “Laser Pumping in the Scheme of an Mx-Magnetometer,” Opt. Spectrosc.78, 292–298 (1995).

Shah, V.

P. D. D. Schwindt, B. Lindseth, S. Knappe, V. Shah, J. Kitching, and L.-A. Liew, “Chip-scale atomic magnetometer with improved sensitivity by use of the Mx technique,” Appl. Phys. Lett.90(8), 081102 (2007).
[CrossRef]

Smith, K.

R. Jimenez-Martinez, W. C. Griffith, Y.-J. Wang, S. Knappe, J. Kitching, K. Smith, and M. Prouty, “Sensitivity Comparison of Mx and Frequency-Modulated Bell-Bloom Cs Magnetometers in a Microfabricated Cell,” IEEE Trans. Instrum. Meas.59(2), 372–378 (2010).
[CrossRef]

Velichanskii, V. L.

E. B. Aleksandrov, M. V. Balabas, A. K. Vershovskii, A. E. Ivanov, N. N. Yakobson, V. L. Velichanskii, and N. V. Senkov, “Laser Pumping in the Scheme of an Mx-Magnetometer,” Opt. Spectrosc.78, 292–298 (1995).

Vershovskii, A. K.

E. B. Aleksandrov, M. V. Balabas, A. K. Vershovskii, A. E. Ivanov, N. N. Yakobson, V. L. Velichanskii, and N. V. Senkov, “Laser Pumping in the Scheme of an Mx-Magnetometer,” Opt. Spectrosc.78, 292–298 (1995).

Wang, Y.-J.

R. Jimenez-Martinez, W. C. Griffith, Y.-J. Wang, S. Knappe, J. Kitching, K. Smith, and M. Prouty, “Sensitivity Comparison of Mx and Frequency-Modulated Bell-Bloom Cs Magnetometers in a Microfabricated Cell,” IEEE Trans. Instrum. Meas.59(2), 372–378 (2010).
[CrossRef]

Weis, A.

N. Castagna, G. Bison, G. Domenico, A. Hofer, P. Knowles, C. Macchione, H. Saudan, and A. Weis, “A large sample study of spin relaxation and magnetometric sensitivity of paraffin-coated Cs vapor cells,” Appl. Phys. B96(4), 763–772 (2009).
[CrossRef]

Woetzel, S.

T. Scholtes, V. Schultze, R. IJsselsteijn, S. Woetzel, and H.-G. Meyer, “Erratum: Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell [Phys. Rev. A 84, 043416 (2011)],” Phys. Rev. A86(5), 059904 (2012).
[CrossRef]

V. Schultze, R. Ijsselsteijn, T. Scholtes, S. Woetzel, and H.-G. Meyer, “Characteristics and performance of an intensity-modulated optically pumped magnetometer in comparison to the classical M(x) magnetometer,” Opt. Express20(13), 14201–14212 (2012).
[CrossRef] [PubMed]

T. Scholtes, V. Schultze, R. IJsselsteijn, S. Woetzel, and H.-G. Meyer, “Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell,” Phys. Rev. A84(4), 043416 (2011).
[CrossRef]

Yakobson, N. N.

E. B. Aleksandrov, M. V. Balabas, A. K. Vershovskii, A. E. Ivanov, N. N. Yakobson, V. L. Velichanskii, and N. V. Senkov, “Laser Pumping in the Scheme of an Mx-Magnetometer,” Opt. Spectrosc.78, 292–298 (1995).

Appl. Phys. B

N. Castagna, G. Bison, G. Domenico, A. Hofer, P. Knowles, C. Macchione, H. Saudan, and A. Weis, “A large sample study of spin relaxation and magnetometric sensitivity of paraffin-coated Cs vapor cells,” Appl. Phys. B96(4), 763–772 (2009).
[CrossRef]

Appl. Phys. Lett.

P. D. D. Schwindt, B. Lindseth, S. Knappe, V. Shah, J. Kitching, and L.-A. Liew, “Chip-scale atomic magnetometer with improved sensitivity by use of the Mx technique,” Appl. Phys. Lett.90(8), 081102 (2007).
[CrossRef]

IEEE Trans. Instrum. Meas.

R. Jimenez-Martinez, W. C. Griffith, Y.-J. Wang, S. Knappe, J. Kitching, K. Smith, and M. Prouty, “Sensitivity Comparison of Mx and Frequency-Modulated Bell-Bloom Cs Magnetometers in a Microfabricated Cell,” IEEE Trans. Instrum. Meas.59(2), 372–378 (2010).
[CrossRef]

Opt. Express

Opt. Spectrosc.

E. B. Aleksandrov, M. V. Balabas, A. K. Vershovskii, A. E. Ivanov, N. N. Yakobson, V. L. Velichanskii, and N. V. Senkov, “Laser Pumping in the Scheme of an Mx-Magnetometer,” Opt. Spectrosc.78, 292–298 (1995).

Phys. Rev. A

T. Scholtes, V. Schultze, R. IJsselsteijn, S. Woetzel, and H.-G. Meyer, “Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell,” Phys. Rev. A84(4), 043416 (2011).
[CrossRef]

T. Scholtes, V. Schultze, R. IJsselsteijn, S. Woetzel, and H.-G. Meyer, “Erratum: Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell [Phys. Rev. A 84, 043416 (2011)],” Phys. Rev. A86(5), 059904 (2012).
[CrossRef]

Cited By

OSA participates in CrossRef's Cited-By Linking service. Citing articles from OSA journals and other participating publishers are listed here.

Alert me when this article is cited.


Tables (1)

Tables Icon

Table 2 Parameters of selected magnetometers

Metrics