Abstract

Total hip arthroplasty (THA) significantly improves the quality of life in majority of patients with severe osteoarthritis. However, long-term outcomes of THAs are compromised by aseptic loosening and periprosthetic osteolysis which needs revision surgery. Both of these are causally linked to a prosthetic wear deliberated from the prosthetic articulating surfaces. As a result, there is a need to measure the mode and magnitude of wear. The paper evaluates three optical methods proposed for construction of a device for the non-contact prosthetic wear measurement. Of them, the scanning profilometry achieved promising combination of accuracy and repeatability. Simultaneously, it is time efficient to enable the development of a sensor for wear measurement.

© 2009 Optical Society of America

Full Article  |  PDF Article

References

  • View by:
  • |
  • |
  • |

  1. S. M. Kurtz, K. L. Ong, J. Schmier et al., "Future clinical and economic impact of revision total hip and knee arthroplasty," J. Bone Joint Surg. Am. 89, 144-51 (2007).
    [CrossRef] [PubMed]
  2. J. Gallo, P. Kaminek, V. Ticha, P. Rihakova, and R. Ditmar, "Particle disease. A comprehensive theory of periprosthetic osteolysis: a review," Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 146, 21-8 (2002).
  3. J. H. Dumbleton, M. T. Manley, and A. A. Edidin, "A literature review of the association between wear rate and osteolysis in total hip arthroplasty," J. Arthroplasty 17, 649-61 (2002).
    [CrossRef] [PubMed]
  4. J. Gallo, V. Havranek, I. Cechova, and J. Zapletalova, "Wear measurement of retrieved polyethylene ABG 1 cups by universal-type measuring microscope and X-ray methods," Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 150, 321-6 (2006).
  5. T. von Schewelov, L. Sanzen, N. Borlin, P. Markusson, and I. Onsten, "Accuracy of radiographic and radiostereometric wear measurement of different hip prostheses: an experimental study," Acta Orthop. Scand. 75, 691-700 (2004).
    [CrossRef]
  6. J. Gallo, V. Havranek, and J. Zapletalova, "Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty," Int. Orthop. (in press)
  7. D. Malacara, Optical Shop Testing (Wiley, 1992).
  8. M. Gruber and G. Haeusler, "Simple, robust and accurate phase-measuring triangulation," Optik 89, 118-22 (1992).
  9. M. Pochmon, T. Rossler, D. Mandat, J. Gallo, and M. Hrabovsky, "Verification of abrasion measurement of juncture implants using Fourier profilometry," Proc. SPIE 6609, 660919 (2007).
    [CrossRef]
  10. P. Cielo, Optical Techniques for Industrial Inspection (Academic Press, 1988).
  11. A. Asundi and M. R. Sajan, "Mapping algorithm for 360-deg profilometry with time delayed integration imaging," Opt Eng 38, 339-43 (1999).
    [CrossRef]
  12. D. Mandat, T. Rossler, M. Pech, M. Hrabovsky, L. Nozka, M. Pochmon, and J. Gallo, "Validation of 3D scanning profilometry using total knee arthroplasty sample," Proc. SPIE 6609, 660914 (2007).
    [CrossRef]
  13. A. Berzins, D. R. Sumner, and J. O. Galante, "Dimensional characteristics of uncomplicated autopsy-retrieved acetabular polyethylene liners by ultrasound," J. Biomed. Mater Res. 39, 120-9 (1998).
    [CrossRef] [PubMed]
  14. M. B. Collier, M. J. Kraay, C. M. Rimnac, and V. M. Goldberg, "Evaluation of contemporary software methods used to quantify polyethylene wear after total hip arthroplasty," J. Bone Joint Surg. Am. 85, 2410-8 (2003).
    [PubMed]
  15. M. Jasty, D. D. Goetz, C. R. Bragdon, K. R. Lee, A. E. Hanson, J. R. Elder, and W. H. Harris, "Wear of Polyethylene Acetabular Components in Total Hip Arthroplasty. An Analysis of One Hundred and Twenty-eight Components Retrieved at Autopsy or Revision Operations," J. Bone Joint Surg. Am. 79, 349-58 (1997).
    [PubMed]
  16. T. Mizoue, K. Yamamoto, T. Masaoka, A. Imakiire, M. Akagi, and I. C. Clarke, "Validation of acetabular cup wear volume based on direct and two-dimensional measurements: hip simulator analysis," J. Orthop. Sci. 8, 491-9 (2003).
    [CrossRef] [PubMed]

2007

S. M. Kurtz, K. L. Ong, J. Schmier et al., "Future clinical and economic impact of revision total hip and knee arthroplasty," J. Bone Joint Surg. Am. 89, 144-51 (2007).
[CrossRef] [PubMed]

M. Pochmon, T. Rossler, D. Mandat, J. Gallo, and M. Hrabovsky, "Verification of abrasion measurement of juncture implants using Fourier profilometry," Proc. SPIE 6609, 660919 (2007).
[CrossRef]

D. Mandat, T. Rossler, M. Pech, M. Hrabovsky, L. Nozka, M. Pochmon, and J. Gallo, "Validation of 3D scanning profilometry using total knee arthroplasty sample," Proc. SPIE 6609, 660914 (2007).
[CrossRef]

2006

J. Gallo, V. Havranek, I. Cechova, and J. Zapletalova, "Wear measurement of retrieved polyethylene ABG 1 cups by universal-type measuring microscope and X-ray methods," Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 150, 321-6 (2006).

2004

T. von Schewelov, L. Sanzen, N. Borlin, P. Markusson, and I. Onsten, "Accuracy of radiographic and radiostereometric wear measurement of different hip prostheses: an experimental study," Acta Orthop. Scand. 75, 691-700 (2004).
[CrossRef]

2003

M. B. Collier, M. J. Kraay, C. M. Rimnac, and V. M. Goldberg, "Evaluation of contemporary software methods used to quantify polyethylene wear after total hip arthroplasty," J. Bone Joint Surg. Am. 85, 2410-8 (2003).
[PubMed]

T. Mizoue, K. Yamamoto, T. Masaoka, A. Imakiire, M. Akagi, and I. C. Clarke, "Validation of acetabular cup wear volume based on direct and two-dimensional measurements: hip simulator analysis," J. Orthop. Sci. 8, 491-9 (2003).
[CrossRef] [PubMed]

2002

J. Gallo, P. Kaminek, V. Ticha, P. Rihakova, and R. Ditmar, "Particle disease. A comprehensive theory of periprosthetic osteolysis: a review," Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 146, 21-8 (2002).

J. H. Dumbleton, M. T. Manley, and A. A. Edidin, "A literature review of the association between wear rate and osteolysis in total hip arthroplasty," J. Arthroplasty 17, 649-61 (2002).
[CrossRef] [PubMed]

1999

A. Asundi and M. R. Sajan, "Mapping algorithm for 360-deg profilometry with time delayed integration imaging," Opt Eng 38, 339-43 (1999).
[CrossRef]

1998

A. Berzins, D. R. Sumner, and J. O. Galante, "Dimensional characteristics of uncomplicated autopsy-retrieved acetabular polyethylene liners by ultrasound," J. Biomed. Mater Res. 39, 120-9 (1998).
[CrossRef] [PubMed]

1997

M. Jasty, D. D. Goetz, C. R. Bragdon, K. R. Lee, A. E. Hanson, J. R. Elder, and W. H. Harris, "Wear of Polyethylene Acetabular Components in Total Hip Arthroplasty. An Analysis of One Hundred and Twenty-eight Components Retrieved at Autopsy or Revision Operations," J. Bone Joint Surg. Am. 79, 349-58 (1997).
[PubMed]

1992

M. Gruber and G. Haeusler, "Simple, robust and accurate phase-measuring triangulation," Optik 89, 118-22 (1992).

Akagi, M.

T. Mizoue, K. Yamamoto, T. Masaoka, A. Imakiire, M. Akagi, and I. C. Clarke, "Validation of acetabular cup wear volume based on direct and two-dimensional measurements: hip simulator analysis," J. Orthop. Sci. 8, 491-9 (2003).
[CrossRef] [PubMed]

Asundi, A.

A. Asundi and M. R. Sajan, "Mapping algorithm for 360-deg profilometry with time delayed integration imaging," Opt Eng 38, 339-43 (1999).
[CrossRef]

Berzins, A.

A. Berzins, D. R. Sumner, and J. O. Galante, "Dimensional characteristics of uncomplicated autopsy-retrieved acetabular polyethylene liners by ultrasound," J. Biomed. Mater Res. 39, 120-9 (1998).
[CrossRef] [PubMed]

Borlin, N.

T. von Schewelov, L. Sanzen, N. Borlin, P. Markusson, and I. Onsten, "Accuracy of radiographic and radiostereometric wear measurement of different hip prostheses: an experimental study," Acta Orthop. Scand. 75, 691-700 (2004).
[CrossRef]

Bragdon, C. R.

M. Jasty, D. D. Goetz, C. R. Bragdon, K. R. Lee, A. E. Hanson, J. R. Elder, and W. H. Harris, "Wear of Polyethylene Acetabular Components in Total Hip Arthroplasty. An Analysis of One Hundred and Twenty-eight Components Retrieved at Autopsy or Revision Operations," J. Bone Joint Surg. Am. 79, 349-58 (1997).
[PubMed]

Cechova, I.

J. Gallo, V. Havranek, I. Cechova, and J. Zapletalova, "Wear measurement of retrieved polyethylene ABG 1 cups by universal-type measuring microscope and X-ray methods," Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 150, 321-6 (2006).

Clarke, I. C.

T. Mizoue, K. Yamamoto, T. Masaoka, A. Imakiire, M. Akagi, and I. C. Clarke, "Validation of acetabular cup wear volume based on direct and two-dimensional measurements: hip simulator analysis," J. Orthop. Sci. 8, 491-9 (2003).
[CrossRef] [PubMed]

Collier, M. B.

M. B. Collier, M. J. Kraay, C. M. Rimnac, and V. M. Goldberg, "Evaluation of contemporary software methods used to quantify polyethylene wear after total hip arthroplasty," J. Bone Joint Surg. Am. 85, 2410-8 (2003).
[PubMed]

Ditmar, R.

J. Gallo, P. Kaminek, V. Ticha, P. Rihakova, and R. Ditmar, "Particle disease. A comprehensive theory of periprosthetic osteolysis: a review," Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 146, 21-8 (2002).

Dumbleton, J. H.

J. H. Dumbleton, M. T. Manley, and A. A. Edidin, "A literature review of the association between wear rate and osteolysis in total hip arthroplasty," J. Arthroplasty 17, 649-61 (2002).
[CrossRef] [PubMed]

Edidin, A. A.

J. H. Dumbleton, M. T. Manley, and A. A. Edidin, "A literature review of the association between wear rate and osteolysis in total hip arthroplasty," J. Arthroplasty 17, 649-61 (2002).
[CrossRef] [PubMed]

Elder, J. R.

M. Jasty, D. D. Goetz, C. R. Bragdon, K. R. Lee, A. E. Hanson, J. R. Elder, and W. H. Harris, "Wear of Polyethylene Acetabular Components in Total Hip Arthroplasty. An Analysis of One Hundred and Twenty-eight Components Retrieved at Autopsy or Revision Operations," J. Bone Joint Surg. Am. 79, 349-58 (1997).
[PubMed]

Galante, J. O.

A. Berzins, D. R. Sumner, and J. O. Galante, "Dimensional characteristics of uncomplicated autopsy-retrieved acetabular polyethylene liners by ultrasound," J. Biomed. Mater Res. 39, 120-9 (1998).
[CrossRef] [PubMed]

Gallo, J.

D. Mandat, T. Rossler, M. Pech, M. Hrabovsky, L. Nozka, M. Pochmon, and J. Gallo, "Validation of 3D scanning profilometry using total knee arthroplasty sample," Proc. SPIE 6609, 660914 (2007).
[CrossRef]

M. Pochmon, T. Rossler, D. Mandat, J. Gallo, and M. Hrabovsky, "Verification of abrasion measurement of juncture implants using Fourier profilometry," Proc. SPIE 6609, 660919 (2007).
[CrossRef]

J. Gallo, V. Havranek, I. Cechova, and J. Zapletalova, "Wear measurement of retrieved polyethylene ABG 1 cups by universal-type measuring microscope and X-ray methods," Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 150, 321-6 (2006).

J. Gallo, P. Kaminek, V. Ticha, P. Rihakova, and R. Ditmar, "Particle disease. A comprehensive theory of periprosthetic osteolysis: a review," Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 146, 21-8 (2002).

J. Gallo, V. Havranek, and J. Zapletalova, "Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty," Int. Orthop. (in press)

Goetz, D. D.

M. Jasty, D. D. Goetz, C. R. Bragdon, K. R. Lee, A. E. Hanson, J. R. Elder, and W. H. Harris, "Wear of Polyethylene Acetabular Components in Total Hip Arthroplasty. An Analysis of One Hundred and Twenty-eight Components Retrieved at Autopsy or Revision Operations," J. Bone Joint Surg. Am. 79, 349-58 (1997).
[PubMed]

Goldberg, V. M.

M. B. Collier, M. J. Kraay, C. M. Rimnac, and V. M. Goldberg, "Evaluation of contemporary software methods used to quantify polyethylene wear after total hip arthroplasty," J. Bone Joint Surg. Am. 85, 2410-8 (2003).
[PubMed]

Gruber, M.

M. Gruber and G. Haeusler, "Simple, robust and accurate phase-measuring triangulation," Optik 89, 118-22 (1992).

Haeusler, G.

M. Gruber and G. Haeusler, "Simple, robust and accurate phase-measuring triangulation," Optik 89, 118-22 (1992).

Hanson, A. E.

M. Jasty, D. D. Goetz, C. R. Bragdon, K. R. Lee, A. E. Hanson, J. R. Elder, and W. H. Harris, "Wear of Polyethylene Acetabular Components in Total Hip Arthroplasty. An Analysis of One Hundred and Twenty-eight Components Retrieved at Autopsy or Revision Operations," J. Bone Joint Surg. Am. 79, 349-58 (1997).
[PubMed]

Harris, W. H.

M. Jasty, D. D. Goetz, C. R. Bragdon, K. R. Lee, A. E. Hanson, J. R. Elder, and W. H. Harris, "Wear of Polyethylene Acetabular Components in Total Hip Arthroplasty. An Analysis of One Hundred and Twenty-eight Components Retrieved at Autopsy or Revision Operations," J. Bone Joint Surg. Am. 79, 349-58 (1997).
[PubMed]

Havranek, V.

J. Gallo, V. Havranek, I. Cechova, and J. Zapletalova, "Wear measurement of retrieved polyethylene ABG 1 cups by universal-type measuring microscope and X-ray methods," Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 150, 321-6 (2006).

J. Gallo, V. Havranek, and J. Zapletalova, "Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty," Int. Orthop. (in press)

Hrabovsky, M.

M. Pochmon, T. Rossler, D. Mandat, J. Gallo, and M. Hrabovsky, "Verification of abrasion measurement of juncture implants using Fourier profilometry," Proc. SPIE 6609, 660919 (2007).
[CrossRef]

D. Mandat, T. Rossler, M. Pech, M. Hrabovsky, L. Nozka, M. Pochmon, and J. Gallo, "Validation of 3D scanning profilometry using total knee arthroplasty sample," Proc. SPIE 6609, 660914 (2007).
[CrossRef]

Imakiire, A.

T. Mizoue, K. Yamamoto, T. Masaoka, A. Imakiire, M. Akagi, and I. C. Clarke, "Validation of acetabular cup wear volume based on direct and two-dimensional measurements: hip simulator analysis," J. Orthop. Sci. 8, 491-9 (2003).
[CrossRef] [PubMed]

Jasty, M.

M. Jasty, D. D. Goetz, C. R. Bragdon, K. R. Lee, A. E. Hanson, J. R. Elder, and W. H. Harris, "Wear of Polyethylene Acetabular Components in Total Hip Arthroplasty. An Analysis of One Hundred and Twenty-eight Components Retrieved at Autopsy or Revision Operations," J. Bone Joint Surg. Am. 79, 349-58 (1997).
[PubMed]

Kaminek, P.

J. Gallo, P. Kaminek, V. Ticha, P. Rihakova, and R. Ditmar, "Particle disease. A comprehensive theory of periprosthetic osteolysis: a review," Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 146, 21-8 (2002).

Kraay, M. J.

M. B. Collier, M. J. Kraay, C. M. Rimnac, and V. M. Goldberg, "Evaluation of contemporary software methods used to quantify polyethylene wear after total hip arthroplasty," J. Bone Joint Surg. Am. 85, 2410-8 (2003).
[PubMed]

Kurtz, S. M.

S. M. Kurtz, K. L. Ong, J. Schmier et al., "Future clinical and economic impact of revision total hip and knee arthroplasty," J. Bone Joint Surg. Am. 89, 144-51 (2007).
[CrossRef] [PubMed]

Lee, K. R.

M. Jasty, D. D. Goetz, C. R. Bragdon, K. R. Lee, A. E. Hanson, J. R. Elder, and W. H. Harris, "Wear of Polyethylene Acetabular Components in Total Hip Arthroplasty. An Analysis of One Hundred and Twenty-eight Components Retrieved at Autopsy or Revision Operations," J. Bone Joint Surg. Am. 79, 349-58 (1997).
[PubMed]

Mandat, D.

D. Mandat, T. Rossler, M. Pech, M. Hrabovsky, L. Nozka, M. Pochmon, and J. Gallo, "Validation of 3D scanning profilometry using total knee arthroplasty sample," Proc. SPIE 6609, 660914 (2007).
[CrossRef]

M. Pochmon, T. Rossler, D. Mandat, J. Gallo, and M. Hrabovsky, "Verification of abrasion measurement of juncture implants using Fourier profilometry," Proc. SPIE 6609, 660919 (2007).
[CrossRef]

Manley, M. T.

J. H. Dumbleton, M. T. Manley, and A. A. Edidin, "A literature review of the association between wear rate and osteolysis in total hip arthroplasty," J. Arthroplasty 17, 649-61 (2002).
[CrossRef] [PubMed]

Markusson, P.

T. von Schewelov, L. Sanzen, N. Borlin, P. Markusson, and I. Onsten, "Accuracy of radiographic and radiostereometric wear measurement of different hip prostheses: an experimental study," Acta Orthop. Scand. 75, 691-700 (2004).
[CrossRef]

Masaoka, T.

T. Mizoue, K. Yamamoto, T. Masaoka, A. Imakiire, M. Akagi, and I. C. Clarke, "Validation of acetabular cup wear volume based on direct and two-dimensional measurements: hip simulator analysis," J. Orthop. Sci. 8, 491-9 (2003).
[CrossRef] [PubMed]

Mizoue, T.

T. Mizoue, K. Yamamoto, T. Masaoka, A. Imakiire, M. Akagi, and I. C. Clarke, "Validation of acetabular cup wear volume based on direct and two-dimensional measurements: hip simulator analysis," J. Orthop. Sci. 8, 491-9 (2003).
[CrossRef] [PubMed]

Nozka, L.

D. Mandat, T. Rossler, M. Pech, M. Hrabovsky, L. Nozka, M. Pochmon, and J. Gallo, "Validation of 3D scanning profilometry using total knee arthroplasty sample," Proc. SPIE 6609, 660914 (2007).
[CrossRef]

Ong, K. L.

S. M. Kurtz, K. L. Ong, J. Schmier et al., "Future clinical and economic impact of revision total hip and knee arthroplasty," J. Bone Joint Surg. Am. 89, 144-51 (2007).
[CrossRef] [PubMed]

Onsten, I.

T. von Schewelov, L. Sanzen, N. Borlin, P. Markusson, and I. Onsten, "Accuracy of radiographic and radiostereometric wear measurement of different hip prostheses: an experimental study," Acta Orthop. Scand. 75, 691-700 (2004).
[CrossRef]

Pech, M.

D. Mandat, T. Rossler, M. Pech, M. Hrabovsky, L. Nozka, M. Pochmon, and J. Gallo, "Validation of 3D scanning profilometry using total knee arthroplasty sample," Proc. SPIE 6609, 660914 (2007).
[CrossRef]

Pochmon, M.

D. Mandat, T. Rossler, M. Pech, M. Hrabovsky, L. Nozka, M. Pochmon, and J. Gallo, "Validation of 3D scanning profilometry using total knee arthroplasty sample," Proc. SPIE 6609, 660914 (2007).
[CrossRef]

M. Pochmon, T. Rossler, D. Mandat, J. Gallo, and M. Hrabovsky, "Verification of abrasion measurement of juncture implants using Fourier profilometry," Proc. SPIE 6609, 660919 (2007).
[CrossRef]

Rihakova, P.

J. Gallo, P. Kaminek, V. Ticha, P. Rihakova, and R. Ditmar, "Particle disease. A comprehensive theory of periprosthetic osteolysis: a review," Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 146, 21-8 (2002).

Rimnac, C. M.

M. B. Collier, M. J. Kraay, C. M. Rimnac, and V. M. Goldberg, "Evaluation of contemporary software methods used to quantify polyethylene wear after total hip arthroplasty," J. Bone Joint Surg. Am. 85, 2410-8 (2003).
[PubMed]

Rossler, T.

M. Pochmon, T. Rossler, D. Mandat, J. Gallo, and M. Hrabovsky, "Verification of abrasion measurement of juncture implants using Fourier profilometry," Proc. SPIE 6609, 660919 (2007).
[CrossRef]

D. Mandat, T. Rossler, M. Pech, M. Hrabovsky, L. Nozka, M. Pochmon, and J. Gallo, "Validation of 3D scanning profilometry using total knee arthroplasty sample," Proc. SPIE 6609, 660914 (2007).
[CrossRef]

Sajan, M. R.

A. Asundi and M. R. Sajan, "Mapping algorithm for 360-deg profilometry with time delayed integration imaging," Opt Eng 38, 339-43 (1999).
[CrossRef]

Sanzen, L.

T. von Schewelov, L. Sanzen, N. Borlin, P. Markusson, and I. Onsten, "Accuracy of radiographic and radiostereometric wear measurement of different hip prostheses: an experimental study," Acta Orthop. Scand. 75, 691-700 (2004).
[CrossRef]

Schmier, J.

S. M. Kurtz, K. L. Ong, J. Schmier et al., "Future clinical and economic impact of revision total hip and knee arthroplasty," J. Bone Joint Surg. Am. 89, 144-51 (2007).
[CrossRef] [PubMed]

Sumner, D. R.

A. Berzins, D. R. Sumner, and J. O. Galante, "Dimensional characteristics of uncomplicated autopsy-retrieved acetabular polyethylene liners by ultrasound," J. Biomed. Mater Res. 39, 120-9 (1998).
[CrossRef] [PubMed]

Ticha, V.

J. Gallo, P. Kaminek, V. Ticha, P. Rihakova, and R. Ditmar, "Particle disease. A comprehensive theory of periprosthetic osteolysis: a review," Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 146, 21-8 (2002).

von Schewelov, T.

T. von Schewelov, L. Sanzen, N. Borlin, P. Markusson, and I. Onsten, "Accuracy of radiographic and radiostereometric wear measurement of different hip prostheses: an experimental study," Acta Orthop. Scand. 75, 691-700 (2004).
[CrossRef]

Yamamoto, K.

T. Mizoue, K. Yamamoto, T. Masaoka, A. Imakiire, M. Akagi, and I. C. Clarke, "Validation of acetabular cup wear volume based on direct and two-dimensional measurements: hip simulator analysis," J. Orthop. Sci. 8, 491-9 (2003).
[CrossRef] [PubMed]

Zapletalova, J.

J. Gallo, V. Havranek, I. Cechova, and J. Zapletalova, "Wear measurement of retrieved polyethylene ABG 1 cups by universal-type measuring microscope and X-ray methods," Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 150, 321-6 (2006).

J. Gallo, V. Havranek, and J. Zapletalova, "Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty," Int. Orthop. (in press)

Acta Orthop. Scand.

T. von Schewelov, L. Sanzen, N. Borlin, P. Markusson, and I. Onsten, "Accuracy of radiographic and radiostereometric wear measurement of different hip prostheses: an experimental study," Acta Orthop. Scand. 75, 691-700 (2004).
[CrossRef]

Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub.

J. Gallo, P. Kaminek, V. Ticha, P. Rihakova, and R. Ditmar, "Particle disease. A comprehensive theory of periprosthetic osteolysis: a review," Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 146, 21-8 (2002).

J. Gallo, V. Havranek, I. Cechova, and J. Zapletalova, "Wear measurement of retrieved polyethylene ABG 1 cups by universal-type measuring microscope and X-ray methods," Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 150, 321-6 (2006).

Int. Orthop.

J. Gallo, V. Havranek, and J. Zapletalova, "Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty," Int. Orthop. (in press)

J. Arthroplasty

J. H. Dumbleton, M. T. Manley, and A. A. Edidin, "A literature review of the association between wear rate and osteolysis in total hip arthroplasty," J. Arthroplasty 17, 649-61 (2002).
[CrossRef] [PubMed]

J. Biomed. Mater Res.

A. Berzins, D. R. Sumner, and J. O. Galante, "Dimensional characteristics of uncomplicated autopsy-retrieved acetabular polyethylene liners by ultrasound," J. Biomed. Mater Res. 39, 120-9 (1998).
[CrossRef] [PubMed]

J. Bone Joint Surg. Am.

M. B. Collier, M. J. Kraay, C. M. Rimnac, and V. M. Goldberg, "Evaluation of contemporary software methods used to quantify polyethylene wear after total hip arthroplasty," J. Bone Joint Surg. Am. 85, 2410-8 (2003).
[PubMed]

M. Jasty, D. D. Goetz, C. R. Bragdon, K. R. Lee, A. E. Hanson, J. R. Elder, and W. H. Harris, "Wear of Polyethylene Acetabular Components in Total Hip Arthroplasty. An Analysis of One Hundred and Twenty-eight Components Retrieved at Autopsy or Revision Operations," J. Bone Joint Surg. Am. 79, 349-58 (1997).
[PubMed]

S. M. Kurtz, K. L. Ong, J. Schmier et al., "Future clinical and economic impact of revision total hip and knee arthroplasty," J. Bone Joint Surg. Am. 89, 144-51 (2007).
[CrossRef] [PubMed]

J. Orthop. Sci.

T. Mizoue, K. Yamamoto, T. Masaoka, A. Imakiire, M. Akagi, and I. C. Clarke, "Validation of acetabular cup wear volume based on direct and two-dimensional measurements: hip simulator analysis," J. Orthop. Sci. 8, 491-9 (2003).
[CrossRef] [PubMed]

Opt Eng

A. Asundi and M. R. Sajan, "Mapping algorithm for 360-deg profilometry with time delayed integration imaging," Opt Eng 38, 339-43 (1999).
[CrossRef]

Optik

M. Gruber and G. Haeusler, "Simple, robust and accurate phase-measuring triangulation," Optik 89, 118-22 (1992).

Proc. SPIE

M. Pochmon, T. Rossler, D. Mandat, J. Gallo, and M. Hrabovsky, "Verification of abrasion measurement of juncture implants using Fourier profilometry," Proc. SPIE 6609, 660919 (2007).
[CrossRef]

D. Mandat, T. Rossler, M. Pech, M. Hrabovsky, L. Nozka, M. Pochmon, and J. Gallo, "Validation of 3D scanning profilometry using total knee arthroplasty sample," Proc. SPIE 6609, 660914 (2007).
[CrossRef]

Other

P. Cielo, Optical Techniques for Industrial Inspection (Academic Press, 1988).

D. Malacara, Optical Shop Testing (Wiley, 1992).

Cited By

OSA participates in CrossRef's Cited-By Linking service. Citing articles from OSA journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (6)

Fig. 1.
Fig. 1.

(a). Principle of measurement by universal measuring microscope; (b) principle of the wear determination – examples of geometry of measurement for 30° and 60° of wear angles.

Fig.2.
Fig.2.

(a). Experimental set-up of the Fourier profilometry; (b) recorded image of the deformed sinusoidal grating; (c) resulting profile map of the cup.

Fig. 3.
Fig. 3.

The geometry of Fourier profilometry.

Fig. 4.
Fig. 4.

(a). The experimental set-up of scanning profilometry; (b) the recorded image of deformed linear strip; c) the resulting WRML map of cup.

Fig.5.
Fig.5.

(a). The geometry of scanning profilometry; (b) the determination of strip deformation.

Fig. 6.
Fig. 6.

Mechanical simulation of wear – geometry of milling.

Tables (4)

Tables Icon

Table 1. Parameters of cup damage (geometry of milling, amount of removed material).

Tables Icon

Table 2. Absolute values of wear measured by methods under the study.

Tables Icon

Table 3. Relative differences of values of wear according to the gravimetric method.

Tables Icon

Table 4. Absolute values of repeated measures and relative standard deviations.

Equations (3)

Equations on this page are rendered with MathJax. Learn more.

W(x,y)=l·p·ΔΦ(x,y)2πp·ΔΦ(x,y)2πd
W(x)=u(x)a·u(x)+b
W(x)=c1·u(x)c2·u2(x)

Metrics