Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Journal of the Optical Society of Korea
  • Vol. 20,
  • Issue 5,
  • pp. 586-592
  • (2016)

A Luminance Compensation Method Using Optical Sensors with Optimized Memory Size for High Image Quality AMOLED Displays

Open Access Open Access

Abstract

This paper proposes a luminance compensation method using optical sensors to achieve high luminance uniformity of active matrix organic light-emitting diode (AMOLED) displays. The proposed method compensates for the non-uniformity of luminance by capturing the luminance of entire pixels and extracting the characteristic parameters. Data modulation using the extracted characteristic parameters is performed to improve luminance uniformity. In addition, memory size is optimized by selecting an optimal bit depth of the extracted characteristic parameters according to the trade-off between the required memory size and luminance uniformity. To verify the proposed compensation method with the optimized memory size, a 40-inch 1920x1080 AMOLED display with a target maximum luminance of 350 cd/m2 is used. The proposed compensation method considering a 4σ range of luminance reduces luminance error from ± 38.64%, ± 36.32%, and ± 43.12% to ± 2.68%, ± 2.64%, and ± 2.76% for red, green, and blue colors, respectively. The optimal bit depth of each characteristic parameter is 6-bit and the total required memory size to achieve high luminance uniformity is 74.6 Mbits.

© 2016 Optical Society of Korea

PDF Article
More Like This
Effects of spatial sampling and luminance quantization on the image quality of color matrix displays

Louis D. Silverstein, John H. Krantz, Frank E. Gomer, Yei-Yu Yeh, and Robert W. Monty
J. Opt. Soc. Am. A 7(10) 1955-1968 (1990)

Optimal scan strategy for mega-pixel and kilo-gray-level OLED-on-silicon microdisplay

Yuan Ji, Feng Ran, Weigui Ji, Meihua Xu, Zhangjing Chen, Yuxi Jiang, and Weixin Shen
Appl. Opt. 51(17) 3731-3743 (2012)

Extended just-noticeable difference for ultralow-luminance displays used in diagnostic imaging

Takushi Kawamorita, Tetsuya Yasuda, Takashi Ota, Tatsuya Iizuka, Makiko Miyasaka, Noritaka Mamorita, and Tomoya Handa
J. Opt. Soc. Am. A 41(4) 581-587 (2024)

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.


Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.