Pixel reassignment in image scanning microscopy: a re-evaluation

Not Accessible

Your library or personal account may give you access

Abstract

Image scanning microscopy is a technique based on confocal microscopy, in which the confocal pinhole is replaced by a detector array, and the resulting image is reconstructed, usually by the process of pixel reassignment. The detector array collects most of the fluorescent light, so the signal-to-noise ratio is much improved compared with confocal microscopy with a small pinhole, while the resolution is improved compared with conventional (wide-field) microscopy. In previous studies, it has usually been assumed that pixels should be reassigned by a constant factor, to a point midway between the illumination and detection spots. Here it is shown that the peak intensity of the effective point spread function (PSF) can be further increased by 4% by a new choice of the pixel reassignment factor. For an array of two Airy units, the peak of the effective PSF is 1.90 times that of a conventional microscope, and the transverse resolution is 1.53 times better. It is confirmed that image scanning microscopy gives optical sectioning strength identical to that of a confocal microscope with a pinhole equal to the size of the detector array. However, it is shown that image scanning microscopy exhibits axial resolution superior to a confocal microscope with a pinhole the same size as the detector array. For a two-Airy-unit array, the axial resolution is 1.34 times better than in a conventional microscope for the standard reassignment factor, and 1.28 times better for the new reassignment factor. The axial resolution of a confocal microscope with a two-Airy-unit pinhole is only 1.04 times better than conventional microscopy. We also examine the signal-to-noise ratio of a point object in a uniform background (called the detectability), and show that it is 1.6 times higher than in a confocal microscope.

© 2019 Optical Society of America

Full Article  |  PDF Article
More Like This
Pixel reassignment in image scanning microscopy with a doughnut beam: example of maximum likelihood restoration

Colin J. R. Sheppard, Marco Castello, Giorgio Tortarolo, Eli Slenders, Takahiro Deguchi, Sami V. Koho, Paolo Bianchini, Giuseppe Vicidomini, and Alberto Diaspro
J. Opt. Soc. Am. A 38(7) 1075-1084 (2021)

Image scanning microscopy with multiphoton excitation or Bessel beam illumination

Colin J. R. Sheppard, Marco Castello, Giorgio Tortarolo, Eli Slenders, Takahiro Deguchi, Sami V. Koho, Giuseppe Vicidomini, and Alberto Diaspro
J. Opt. Soc. Am. A 37(10) 1639-1649 (2020)

Image formation in image scanning microscopy, including the case of two-photon excitation

Colin J. R. Sheppard, Marco Castello, Giorgio Tortarolo, Giuseppe Vicidomini, and Alberto Diaspro
J. Opt. Soc. Am. A 34(8) 1339-1350 (2017)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (16)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved