Development of a polarized hyperspectral imaging system for investigation of absorption and scattering properties

Not Accessible

Your library or personal account may give you access

Abstract

This study was carried out to investigate the feasibility of an original polarized hyperspectral imaging setup in the spectral range of 400–1100 nm for enhancement of absorbance signal measurement on highly scattering samples. Spatial response and spectral calibration have been verified, indicating the consistency of this system and reliability of the acquired data. Model samples consisting of layered sand were prepared and used to uncover the hidden spectral information. In the model matrix, sand worked as scattering particle and dye E141 as absorbing material. Cross (R) and parallel (R||) reflectance signals, along with the back-scattered reflectance, RBS(R||+R) and the weakly scattered reflectance RSS (R||−R) spectra were computed and compared. Results demonstrated that cross-polarized images showed more subsurface information from the second layer due to the rejection of the superficial reflectance, while weakly scattered reflectance (RSS) preserved only the surface information from the first layer. In addition, polarized light spectroscopy absorbance based on Dahm's equation in the frame of the representative layer theory and standard normal variate preprocessing RBS spectra were also obtained from the prepared model matrix. The visual inspection of spectral curves revealed that RSS/RBS and PoLiS absorbance showed two narrow peaks at 405 nm and 630 nm that were less impacted by multi-scattering effects. Partial least squares regression models were developed to predict dye concentration in the mixture sample. Consistent with the spectral profiles, RSS/RBS and PoLiS absorbance presented the best model performances with determination of coefficients of prediction (r2Pred) equal to 0.96 and 0.95, respectively. The resulting distribution maps of S1/S2 sand sample again confirmed the superior performance of RSS/RBS and PoLiS absorbance, manifesting their better ability to reveal chemically related information. The overall results obtained in this research showed that the developed polarized-hyperspectral imaging system coupled with scattering correction methods has great potential for the analysis of powdered or turbid samples.

© 2019 The Author(s)

PDF Article
More Like This
Estimation of bulk optical properties of turbid media from hyperspectral scatter imaging measurements: metamodeling approach

Ben Aernouts, Chyngyz Erkinbaev, Rodrigo Watté, Robbe Van Beers, Nghia Nguyen Do Trong, Bart Nicolai, and Wouter Saeys
Opt. Express 23(20) 26049-26063 (2015)

Quantifying the absorption and reduced scattering coefficients of tissuelike turbid media over a broad spectral range with noncontact Fourier-transform hyperspectral imaging

Tuan H. Pham, Frederic Bevilacqua, Thorsten Spott, Jan S. Dam, Bruce J. Tromberg, and Stefan Andersson-Engels
Appl. Opt. 39(34) 6487-6497 (2000)

Hyperspectral imaging system based on a single-pixel camera design for detecting differences in tissue properties

Joseph Peller, Faramarz Farahi, and Susan R. Trammell
Appl. Opt. 57(27) 7651-7658 (2018)

Supplementary Material (1)

NameDescription
Supplement 1       Supplemental file.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.