Relative Evaluation of Comfort Level Associated with Light-Emitting Diode Lighting Based on near Infrared Spectroscopy

Not Accessible

Your library or personal account may give you access

Abstract

Although the use of light-emitting diode (LED) lighting has rapidly become popular as the next-generation of lighting, the degree of comfort associated with these lights has not been sufficiently examined. Therefore, establishing both subjective and objective evaluation methods to test the comfort associated with LED lightings is desirable. We investigated the comfort associated with LED lighting by using near infrared (NIR) spectroscopy. The study recruited 35 healthy young adults with no ophthalmological diseases. Three types of lighting, including edge-lit LED, direct-lit LED and fluorescent lighting, were used for the subjective evaluation and measurements of the brain function in both Experiment 1 (comfort verification of lighting illuminance) and Experiment 2 (comfort verification of lighting type). Brain measurements were performed using an NIR sensor and by assessing the oxygenated haemoglobin concentration changes in the frontal lobe during the time the subjects looked at each type of light. The subjective evaluation determined that lighting luminance at 800 lux significantly lowered the comfort level, while direct-lit LED and fluorescent lighting significantly lowered the comfort level as compared with edge-lit LED lighting. Lighting illuminance of 800 lux induced a significant increase in oxygenated haemoglobin concentration compared with the control conditions when eyelids were closed. In addition, looking at direct-LED and fluorescent lighting significantly increased oxygenated haemoglobin concentration compared with edge-lit LED lighting. Our study suggests that the subjective comfort level experienced while looking at different types of lighting could potentially be evaluated based on changes in oxygenated haemoglobin concentration within the frontal lobe detected using NIR sensors.

© 2014 IM Publications LLP

PDF Article
More Like This
Flicker-glare and visual-comfort assessments of light emitting diode billboards

Meng-Wei Lin, Pin-Hsuan Hsieh, Erik C. Chang, and Yi-Chun Chen
Appl. Opt. 53(22) E61-E68 (2014)

A new broadband near-infrared spectroscopy system for in-vivo measurements of cerebral cytochrome-c-oxidase changes in neonatal brain injury

Gemma Bale, Subhabrata Mitra, Judith Meek, Nicola Robertson, and Ilias Tachtsidis
Biomed. Opt. Express 5(10) 3450-3466 (2014)

Flicker-glare and visual-comfort assessments of light emitting diode billboards II: color display

Meng-Wei Lin, Ming-Wei Lee, Erik C. Chang, and Yi-Chun Chen
Appl. Opt. 54(13) 4089-4096 (2015)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.