Measurement of the Concentrations of Glucose and Citric Acid in the Aqueous Solution of a Blood Anticoagulant Using near Infrared Spectroscopy

Not Accessible

Your library or personal account may give you access

Abstract

Near infrared (NIR) spectroscopy was employed for the simultaneous prediction of the concentrations of glucose and citric acid in the aqueous solution of a blood anticoagulant solution. The solution was placed in an NIR spectrophotometer and the absorbance at wavelengths between 400 and 2500 nm was measured at 2 nm intervals. Multiple linear regression (MLR) was used to obtain calibration equations relating the NIR spectral data and the glucose and citric acid concentrations of a calibration sample set obtained by enzymatic methods. The value of the multiple correlation coefficient (R) was 0.993 when using the wavelengths of 2274 and 1674 nm for glucose. The value of the simple correlation coefficient (r) for citric acid was 0.993 when using the wavelength 1690 nm. To validate the calibration equations obtained, glucose and citric acid concentrations in a prediction sample set were compared with the concentrations measured by the enzymatic methods. Excellent agreement between the results of the enzymatic method and those of NIR spectroscopy was observed for both constituents. The procedure of NIR spectroscopy was simple and the operation time required to predict the concentrations was a few minutes. These results indicate that NIR spectroscopy may be a useful method for monitoring the production process of the blood anticoagulant.

© 2001 NIR Publications

PDF Article
More Like This
Temperature measurements of turbid aqueous solutions using near-infrared spectroscopy

Naoto Kakuta, Hidenobu Arimoto, Hideyuki Momoki, Fuguo Li, and Yukio Yamada
Appl. Opt. 47(13) 2227-2233 (2008)

Rapid, noninvasive concentration measurements of aqueous biological analytes by near-infrared Raman spectroscopy

Andrew J. Berger, Yang Wang, and Michael S. Feld
Appl. Opt. 35(1) 209-212 (1996)

Determination of glucose in whole blood samples by mid-infrared spectroscopy

Yoen-Joo Kim, Sangjoon Hahn, and Gilwon Yoon
Appl. Opt. 42(4) 745-749 (2003)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.