On the Limit of Detection in Infrared Spectroscopic Imaging

Not Accessible

Your library or personal account may give you access

Abstract

Infrared (IR) spectroscopic imaging instruments’ performance can be characterized and optimized by an analysis of their limit of detection (LOD). Here we report a systematic analysis of the LOD for Fourier transform IR (FT-IR) and discrete frequency IR (DFIR) imaging spectrometers. In addition to traditional measurements of sample and blank data, we propose a decision theory perspective to pose the determination of LOD as a binary classification problem under different assumptions of noise uniformity and correlation. We also examine three spectral analysis approaches, namely, absorbance at a single frequency, average of absorbance over selected frequencies and total spectral distance – to suit instruments that acquire discrete or contiguous spectral bandwidths. The analysis is validated by refining the fabrication of a bovine serum albumin protein microarray to provide eight uniform spots from ∼2.8 nL of solution for each concentration over a wide range (0.05–10 mg/mL). Using scanning parameters that are typical for each instrument, we estimate a LOD of 0.16 mg/mL and 0.12 mg/mL for widefield and line scanning FT-IR imaging systems, respectively, using the spectral distance approach, and 0.22 mg/mL and 0.15 mg/mL using an optimal set of discrete frequencies. As expected, averaging and the use of post-processing techniques such as minimum noise fraction transformation results in LODs as low as ∼0.075 mg/mL that correspond to a spotted protein mass of ∼112 fg/pixel. We emphasize that these measurements were conducted at typical imaging parameters for each instrument and can be improved using the usual trading rules of IR spectroscopy. This systematic analysis and methodology for determining the LOD can allow for quantitative measures of confidence in imaging an analyte's concentration and a basis for further improving IR imaging technology.

© 2021 The Author(s)

PDF Article
More Like This
Infrared spectroscopic imaging detects chemical modifications in liver fibrosis due to diabetes and disease

Hari Sreedhar, Vishal K. Varma, Francesca V. Gambacorta, Grace Guzman, and Michael J. Walsh
Biomed. Opt. Express 7(6) 2419-2424 (2016)

Mercury cadmium telluride focal-plane array detection for mid-infrared Fourier-transform spectroscopic imaging

L. H. Kidder, I. W. Levin, E. Neil Lewis, V. D. Kleiman, and E. J. Heilweil
Opt. Lett. 22(10) 742-744 (1997)

Supplementary Material (2)

NameDescription
Supplement 1       sj-jpg-1-asp-10.1177_00037028211050961 - Supplemental material for On the Limit of Detection in Infrared Spectroscopic Imaging
Supplement 2       sj-jpg-2-asp-10.1177_00037028211050961 - Supplemental material for On the Limit of Detection in Infrared Spectroscopic Imaging

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.