Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 74,
  • Issue 5,
  • pp. 525-535
  • (2020)

Method Transfer Evaluation for Digital Derivative Spectrophotometry Through its Resolution Parameter Comparison of Different Computer Programs

Not Accessible

Your library or personal account may give you access

Abstract

The application assessment of different programs was performed with equivalence tests for method transfer pro second-order derivative spectrophotometry. The digital second-order derivative spectra were calculated on different instruments; GBC Scientific Equipment Cintra 20 (Cintral v.2.6 and Spectral v.1.70 software programs) and Thermo Scientific Evolution 300 (VISIONPro software) were analyzed using the amplitude A/B ratio (A = 2D265,263; B = 2D263,261). Amplitude A/B ratio is the resolution parameter for derivative spectrophotometry prescribed in European Pharmacopoeia. The obtained values for A/B ratio were either very similar or significantly different among programs: 0.669 (Cintral v.2.6), 0.549 (Spectral v.1.70), 0.556 (medium indirect VISIONPro), 0.557 (one-step Savitzky–Golay 7 VISIONPro), 0.689 (two-step Savitzky–Golay 7 VISIONPro). Method transfer was possible between Spectral v.1.70 and VISIONPro (medium indirect and one-step Savitzky–Golay 7), but the values obtained in Cintral v.2.6 were not comparable to the other programs. The absorbance data exported from both instruments were additionally calculated in OriginPro8 which provided almost the same mean A/B values (0.627 Cintral v.2.6; 0.624 VISIONPro), confirming that the two instruments recorded the same zero-order spectra. The calculation of resolution parameter could be used for verification of program comparison, which would enable transfer between sender and receiver laboratory. The accordance between program algorithms was confirmed when acceptable differences for values of resolution parameter (A/B ratios) were achieved.

© 2020 The Author(s)

PDF Article
More Like This
Computer Programs for Absorption Spectrophotometry

R. Norman Jones
Appl. Opt. 8(3) 597-601 (1969)

Generalized method for evaluating scattering parameters used in radiative transfer models

William E. Vargas and Gunnar A. Niklasson
J. Opt. Soc. Am. A 14(9) 2243-2252 (1997)

Derivative Absorption and Emission Spectrophotometry

F. Grum, D. Paine, and L. Zoeller
Appl. Opt. 11(1) 93-98 (1972)

Supplementary Material (2)

NameDescription
Supplement 1       ASP889374 Supplemental Material1 - Supplemental material for Method Transfer Evaluation for Digital Derivative Spectrophotometry Through its Resolution Parameter Comparison of Different Computer Programs
Supplement 2       ASP889374 Supplemental Material2 - Supplemental material for Method Transfer Evaluation for Digital Derivative Spectrophotometry Through its Resolution Parameter Comparison of Different Computer Programs

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.