Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 73,
  • Issue 6,
  • pp. 610-622
  • (2019)

Performance Evaluation of a Time-Gated Fluorescence Spectroscopy Measurement System for the Classification and Recycling of Plastics

Not Accessible

Your library or personal account may give you access

Abstract

Plastics have many unrivaled properties and are thus indispensable materials with an ever-increasing production. Since the plastics recycling rates are still small, the plastic waste that ends up on landfills, in the environment including oceans, and incineration plants also steadily grows. Large-scale automated sorting of waste plastics may help solve the problem. However, most state-of-the-art approaches are limited to a (very) small number of plastic types that can be simultaneously sorted and have severe difficulties with black plastics. The labeling of plastics with fluorescent tracers (“markers”) during their production has the potential to enable the fast and highly reliable classification and automated sorting of many different plastic types simultaneously. Unfortunately, the unique marker fluorescence (“optical fingerprint”) might be obscured by the autofluorescence (AF) often emitted by plastics. Recently, we have shown that time-gated fluorescence spectroscopy (TGFS) can be successfully applied to eliminate the influences from AF. In this study, we present the prototype of a TGFS measurement system for the classification and sorting of plastics and evaluate its performance in a typical industrial situation. With 150 000 investigated plastics flakes from 10 different plastic types that were labeled with binary combinations of six fluorescent markers, an overall plastics recovery rate (mean true positive rate TPR¯) of 99.76%, and a plastics purity (positive predictive value PPV¯) of 99.88% were achieved. Additional simulations that were carried out based upon the experiments allow a prediction of the performance as a function of the signal-to-noise (S/N) ratio such that various system parameters can be adapted to the particular situation.

© 2019 The Author(s)

PDF Article
More Like This
Material classification based on a SWIR discrete spectroscopy approach

Anju Manakkakudy, Andrea De Iacovo, Emanuele Maiorana, Federica Mitri, and Lorenzo Colace
Appl. Opt. 62(35) 9228-9237 (2023)

Performance and limitation estimation of a three-tap gated imaging sensor in wide field time-gated fluorescence lifetime imaging systems

Yun-Tzu Chang, Edward Van Sieleghem, Jiwon Lee, Pol Van Dorpe, and Chris Van Hoof
Appl. Opt. 60(24) 7446-7454 (2021)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.