We studied changes in laser-induced breakdown spectroscopy (LIBS) signal intensity with the thickness of a liquid layer placed on a solid substrate, where an easily evaporating methanol sample was used. For a certain optimal liquid film thickness we obtained a manifold increase of the LIBS signal from methanol. Progressive liquid film thinning leads to a reduction and a successive disappearance of laser-induced splashes; the latter condition drastically reduces the sample consumption and allows measurements to be repeated many times on a single liquid droplet. In following, we developed two methods for actively controlled deformation, i.e., thinning of a liquid droplet (volume ∼10 µl) prior to its sampling by LIBS. Control of the droplet’s height was achieved on a Si–SiO2 wafer substrate by electro-wetting in the case of water solutions or by target rotation in the case of viscous liquids. The chosen substrate also has the advantages of low cost, easy manipulation, and very high purity, thus minimizing interference with analytes. Through the droplet deformation, in a single-pulse excitation at moderate laser energy (70 mJ), we clearly detected Fe and Mn in peanut oil, which represent trace elements in edible oils (∼ 1 part per billion), according to results published in the literature.

© 2017 The Author(s)

PDF Article
More Like This
Highly sensitive detection of sodium in aqueous solutions using laser-induced breakdown spectroscopy with liquid sheet jets

Ryuzo Nakanishi, Hironori Ohba, Morihisa Saeki, Ikuo Wakaida, Rie Tanabe-Yamagishi, and Yoshiro Ito
Opt. Express 29(4) 5205-5212 (2021)

Highly concentrated, ring-shaped phase conversion laser-induced breakdown spectroscopy technology for liquid sample analysis

Qingyu Lin, Zhimei Wei, Hongli Guo, Shuai Wang, Guangmeng Guo, Zhi Zhang, and Yixiang Duan
Appl. Opt. 56(17) 5092-5098 (2017)

Effect of liquid-sheet thickness on detection sensitivity for laser-induced breakdown spectroscopy of aqueous solution

Hironori Ohba, Morihisa Saeki, Ikuo Wakaida, Rie Tanabe, and Yoshiro Ito
Opt. Express 22(20) 24478-24490 (2014)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.