Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 70,
  • Issue 3,
  • pp. 543-551
  • (2016)

Preconcentration of Cu(II), Co(II), and Ni(II) using an Optimized Enrichment Procedure: Useful and Alternative Methodology for Flame Atomic Absorption Spectrometry

Not Accessible

Your library or personal account may give you access

Abstract

In this paper, a new solid phase extraction procedure is described for Cu(II), Co(II), and Ni(II). Silica gel which was coated with N,N’-bis(4-methoxysalicylidene) ethylenediamine (MSE) is used as a sorbent. Three independent variables were optimized using central composite design (CCD) for sorption and elution of metal ions. The optimum values of sorption and elution variables allowed simultaneous preconcentration of the ions in same conditions as follows, for sorption, pH 6.9, flow rate 5.4 mL min–1, sample volume 50.0 mL, and for elution, flow rate 2.6 mL min–1, eluent concentration 1.0 mol L–1, eluent volume 5.0 mL. The detection limits (LOD) were found to be 1.1 µg L–1 for Cu(II), 7.4 µg L–1 for Co(II), and 7.5 µg L–1 for Ni(II) and preconcentration factor was 200 for each of the ions. The accuracy of the method was tested with Lake Ontario water and multi-element standard solution. The proposed method was also applied to various water samples. The proposed method can be alternatively suggested as accurate, precise, easy, and a cheap method for Cu(II), Co(II), and Ni(II) determination.

© 2016 The Author(s)

PDF Article
More Like This
Spectra of Fe, Co, Ni, and Cu Isoelectronic with Na i and Mg i

U. Feldman, L. Katz, W. Behring, and L. Cohen
J. Opt. Soc. Am. 61(1) 91-95 (1971)

Sensitive determinations of Cu, Pb, Cd, and Cr elements in aqueous solutions using chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy

X. Y. Yang, Z. Q. Hao, C. M. Li, J. M. Li, R. X. Yi, M. Shen, K. H. Li, L. B. Guo, X. Y. Li, Y. F. Lu, and X. Y. Zeng
Opt. Express 24(12) 13410-13417 (2016)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.