Measurements of Metal Alkylamide Density During Atomic Layer Deposition Using a Mid-Infrared Light-Emitting Diode (LED) Source

Not Accessible

Your library or personal account may give you access

Abstract

A nondispersive infrared (NDIR) gas analyzer that utilizes a mid-infrared light emitting diode (LED) source was demonstrated for monitoring the metal alkylamide compound tetrakis(dimethylamido) titanium (TDMAT), Ti[N(CH3)2]4. This NDIR gas analyzer was based on direct absorption measurement of TDMAT vapor in the C-H stretching spectral region, a spectral region accessed using a LED with a nominal emission center wavelength of 3.65 μm. The sensitivity of this technique to TDMAT was determined by comparing the absorbance measured using this technique to the TDMAT density as determined using in situ Fourier transform IR (FT-IR) spectroscopy. Fourier transform IR spectroscopy was employed because this technique could be used to (1) quantify TDMAT density in the presence of a carrier gas (the presence of which precludes the use of a capacitance manometer to establish TDMAT density) and (2) distinguish between TDMAT and other gas-phase species containing IR-active C-H stretching modes (allowing separation of the signal from the LED-based optical system into fractions due to TDMAT and other species, when necessary). During TDMAT-only delivery, i.e., in the absence of co-reactants and deposition products, TDMAT minimum detectable molecular densities as low as ≍4 × 1012 cm−3 were demonstrated, with short measurement times and appropriate signal averaging. Reactions involving TDMAT often result in the evolution of the reaction product dimethylamine (DMA), both as a thermal decomposition product in a TDMAT ampoule and as a deposition reaction product in the deposition chamber. Hence, the presence of DMA represents a significant potential interference for this technique, and therefore, the sensitivity of this technique to DMA was also determined by measuring DMA absorbance as a function of pressure. The ratio of the TDMAT sensitivity to the DMA sensitivity was determined to be ≍6.0. To further examine the selectivity of this technique, measurements were also performed during atomic layer deposition (ALD) of titanium dioxide using TDMAT and water. During ALD, potential interferences were expected from the evolution of DMA due to deposition reactions and the deposition on the windows of species containing IR-active C-H stretching modes. It was found that the interfering effects of the evolution of DMA and deposition of species on the windows corresponded to a maximum of only ≍6% of the total observed TDMAT density. However, this level of interference likely is relatively low compared to a typical chemical vapor deposition process in which co-reactants are introduced into the chamber at the same time.

PDF Article
More Like This
Realization of an autonomously controllable process for atomic layer deposition and its encapsulation application in flexible organic light-emitting diodes

Zhenyu Wang, Ziqiang Chen, Jintao Wang, Lianchao Shangguan, Siyu Fan, and Yu Duan
Opt. Express 31(13) 21672-21688 (2023)

High efficiency of III-nitride micro-light-emitting diodes by sidewall passivation using atomic layer deposition

Matthew S. Wong, David Hwang, Abdullah I. Alhassan, Changmin Lee, Ryan Ley, Shuji Nakamura, and Steven P. DenBaars
Opt. Express 26(16) 21324-21331 (2018)

Investigation on reliability of red micro-light emitting diodes with atomic layer deposition passivation layers

Huang-Hsiung Huang, Sheng-Kai Huang, Yi-Lin Tsai, Shou-Wei Wang, Yi-Yang Lee, Shao-Yi Weng, Hao-Chung Kuo, and Chien-chung Lin
Opt. Express 28(25) 38184-38195 (2020)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.