Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 68,
  • Issue 9,
  • pp. 1039-1045
  • (2014)

Quantitative Determination of Manganese in Aqueous Solutions and Seawater by Laser-Induced Breakdown Spectroscopy (LIBS) Using Paper Substrates

Not Accessible

Your library or personal account may give you access

Abstract

The detection of manganese (Mn) in industrial wastewater and seawater plays an important role in pollution monitoring and the investigation of geochemical and biological processes in the ocean. An approach has been introduced in this work to improve the detection sensitivity of Mn in liquids by laser-induced breakdown spectroscopy with a filter paper as solid substrate. The calibration curves of Mn in aqueous solutions were obtained with the detection of a Czerny-Turner spectrometer and an echelle spectrometer, respectively. The results showed that the Czerny-Turner spectrometer equipped with an intensified charge-coupled device (ICCD) had a more sensitive detection of Mn in aqueous solution with this approach. The limit of detection (LOD) for Mn was down to 0.11 mg/L with laser pulse energy of 90 mJ. With the same approach, the compact echelle spectrometer equipped with an ICCD was used to verify the feasibility for rapid onsite detection. The calibration curves for Mn in simulated industrial wastewater and seawater were constructed to calculate relevant LODs. The LODs of Mn were 2.78 mg/L in mixed solutions and 2.73 mg/L in seawater by calculation. Both the calibration curves and LODs were affected slightly by the matrix effect in the experiment. In order to assess the accuracy, a mixed solution including Mn, Cr, Cd, and Cu with known concentrations was determined, and good agreement between the measured and real values were achieved. It demonstrated that this approach has significant potential for rapid onsite detection of Mn and other metal elements in industrial wastewater and seawater.

PDF Article
More Like This
Determination of Ca and Mg in aqueous solution by laser-induced breakdown spectroscopy using absorbent paper substrates

Dehua Zhu, Lizhi Wu, Bin Wang, Jianping Chen, Jian Lu, and Xiaowu Ni
Appl. Opt. 50(29) 5695-5699 (2011)

Determination of trace heavy metal elements in aqueous solution using surface-enhanced laser-induced breakdown spectroscopy

Shixiang Ma, Yun Tang, Yuyang Ma, Yanwu Chu, Feng Chen, Zhenlin Hu, Zhihao Zhu, Lianbo Guo, Xiaoyan Zeng, and Yongfeng Lu
Opt. Express 27(10) 15091-15099 (2019)

Sensitive determinations of Cu, Pb, Cd, and Cr elements in aqueous solutions using chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy

X. Y. Yang, Z. Q. Hao, C. M. Li, J. M. Li, R. X. Yi, M. Shen, K. H. Li, L. B. Guo, X. Y. Li, Y. F. Lu, and X. Y. Zeng
Opt. Express 24(12) 13410-13417 (2016)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.