Characterization of a Variable Angle Reflection Fourier Transform Infrared Accessory Modified for Surface Plasmon Resonance Spectroscopy

Not Accessible

Your library or personal account may give you access

Abstract

The Harrick AutoSeagull variable angle reflection accessory for Fourier transform infrared (FT-IR) spectrometers provides access to various spectroscopic techniques in a highly flexible platform. In particular, its ability to perform total internal reflection measurements is of interest because it also forms the basis for surface plasmon resonance (SPR) spectroscopy in prism-based configurations. The work presented here discusses the modification of the AutoSeagull to perform SPR spectroscopy, allowing for easy incorporation of the technique into most common FT-IR spectrometers. The wavelength dependency of the dielectric constant of the plasmon-supporting metal (in our case, gold) is largely responsible for the sensitivity attributed to changes in the sample's refractive index (RI) monitored by SPR spectroscopy. Furthermore, the optical properties of gold are such that when near-infrared (NIR) and/or mid-infrared (mid-IR) wavelengths are used to excite surface plasmons, higher sensitivities to RI changes are experienced compared to surface plasmons excited with visible wavelengths. The result is that in addition to instrumental simplicity, SPR analysis on FT-IR spectrometers, as permitted by the modified AutoSeagull, also benefits from the wavelength ranges accessible. Adaptation of the AutoSeagull to SPR spectroscopy involved the incorporation of slit apertures to minimize the angular spread reaching the detector, resulting in sharper SPR "dips" but at the cost of noisier spectra. In addition, discussion of the system's analytical performance includes comparison of dip quality as a function of slit size, tailoring of the dip minima location with respect to incident angle, and sensitivity to bulk RI changes.

PDF Article
More Like This
Design analysis of doped-silicon surface plasmon resonance immunosensors in mid-infrared range

William DiPippo, Bong Jae Lee, and Keunhan Park
Opt. Express 18(18) 19396-19406 (2010)

Beam-angle-scanning surface plasmon resonance sensor for rapid, high-precision sensing of refractive index and bio-molecules

Hidenori Koresawa, Kota Seki, Eiji Hase, Yu Tokizane, Takeo Minamikawa, Taka-Aki Yano, Taira Kajisa, and Takeshi Yasui
Opt. Continuum 1(3) 565-574 (2022)

Properties and sensing characteristics of surface-plasmon resonance in infrared light

Sergiy Patskovsky, Andrei V. Kabashin, Michel Meunier, and John H. T. Luong
J. Opt. Soc. Am. A 20(8) 1644-1650 (2003)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved