Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 61,
  • Issue 2,
  • pp. 193-198
  • (2007)

Monitoring 2-Ethylhexyl-4-Methoxycinnamate Photoisomerization on Skin Using Attenuated Total Reflection Fourier Transform Infrared Spectroscopy

Not Accessible

Your library or personal account may give you access

Abstract

Photoisomerization and photodimerization of a widely used UVB filter, 2-ethylhexy-4-methoxycinnamate (EHMC) on a ZnSe surface and baby mouse (<i>Mus musculus</i> Linn.) skin were monitored using attenuated total reflection Fourier transform infrared spectroscopy (ATR-FT-IR). Differentiation between the <i>E</i>- and the <i>Z</i>-EHMC could be achieved by examining the infrared (IR) peak at 981 cm<sup>−1</sup> (b peak), which corresponds to the CH rocking deformation vibration of Ph–CH=CH– detected only in the <i>E</i> configuration. By plotting the ratios of the peak area of the b peak and an internal standard peak (1060–998 cm<sup>−1</sup>) against mole percentage of <i>Z</i>-isomer in the <i>E-Z</i> mixtures, a linear calibration plot was obtained. Thus, a simple estimation of the mole percentage of each configuration in a sample was obtained. At the same UVB exposure, photostationary equilibrium of the <i>E</i>/<i>Z</i> isomerization on the surface varied with the applied amounts of EHMC. Photoisomerizations on ZnSe and on baby mouse skin were comparable. Less than 10% of <i>E</i>-EHMC changed configuration when the mouse skins applied with 1.0–4.0 mg/cm<sup>2</sup> <i>E</i>-EHMC were exposed to sunlight for 60 min (UVB radiant exposure of ∼0.30 J/cm<sup>2</sup>). This corresponded to less than 5% loss in UV filtering efficiency. However, at a typical EHMC skin coverage (∼0.2 mg/cm<sup>2</sup>), 0.30 J/cm<sup>2</sup> UVB exposure induced ∼50% photoisomerization resulting in 25% loss of UV filtering efficiency. No photodimerization was detected even at the extreme EHMC coverage of 4.0 mg/cm<sup>2</sup> after a UVB exposure of 0.90 J/cm<sup>2</sup>.

PDF Article
More Like This
Use of attenuated total reflectance Fourier transform infrared spectroscopy to monitor the development of lipid aggregate structures

Mateo R. Hernandez, Elyse N. Towns, Terry C. Ng, Brian C. Walsh, Richard Osibanjo, Atul N. Parikh, and Donald P. Land
Appl. Opt. 51(15) 2842-2846 (2012)

Attenuated total reflectance spectroscopy with chirped-pulse upconversion

Hideto Shirai, Constance Duchesne, Yuji Furutani, and Takao Fuji
Opt. Express 22(24) 29611-29616 (2014)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved