Second-Order Calibration of Excitation–Emission Matrix Fluorescence Spectra for the Determination of N-Phenylanthranilic Acid Derivatives

Not Accessible

Your library or personal account may give you access

Abstract

A spectrofluorimetric method has been developed for the quantitative determination of mefenamic, flufenamic, and meclofenamic acids in urine samples. The method is based on second-order data multivariate calibration (unfolded partial least squares (unfolded-PLS), multi-way PLS (N-PLS), parallel factor analysis (PARAFAC), self-weighted alternating trilinear decomposition (SWATLD), and bilinear least squares (BLLS)). The analytes were extracted from the urine samples in chloroform prior to the determination. The chloroform extraction was optimized for each analyte, studying the agitation time and the extraction pH, and the optimum values were 10 minutes and pH 3.5, respectively. The concentration ranges in chloroform solution of each of the analytes, used to construct the calibration matrix, were selected in the ranges from 0.15 to 0.8 μg mL<sup>−1</sup> for flufenamic and meclofenamic acids and from 0.25 to 3.0 μg mL<sup>−1</sup> for mefenamic acid. The combination of chloroform extraction and second-order calibration methods, using the excitation–emission matrices (EEMs) of the three analytes as analytical signals, allowed their simultaneous determination in human urine samples, in the range of approximately 80 mg L<sup>−1</sup> to 250 mg L<sup>−1</sup>, with satisfactory results for all the assayed methods. Improved results over unfolded-PLS and N-PLS were found with PARAFAC, SWATLD, and BLLS, methods that exploit the second-order advantage.

PDF Article
More Like This
Quantifying PAHs in water by three-way fluorescence spectra and second-order calibration methods

Ruifang Yang, Nanjing Zhao, Xue Xiao, Gaofang Yin, Shaohui Yu, Jianguo Liu, and Wenqing Liu
Opt. Express 24(14) A1148-A1157 (2016)

Fourier fluorescence spectrometer for excitation emission matrix measurement

Leilei Peng, Joseph A. Gardecki, Brett E. Bouma, and Guillermo J. Tearney
Opt. Express 16(14) 10493-10500 (2008)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.