Nanoliter Serum Sample Analysis by Mid-infrared Spectroscopy for Minimally Invasive Blood-Glucose Monitoring

Not Accessible

Your library or personal account may give you access

Abstract

The aim of this study was to demonstrate that mid-infrared spectroscopy is able to quantify glucose in a serum matrix with sample volumes well below 1 μL. For this, we applied mid-infrared attenuated total reflectance (ATR) or transmission-based spectroscopic methods to glucose quantification in microsamples of dry-film sera, either undiluted or diluted 10 times in distilled water. The sample series spanned physiological glucose concentrations between 50 and 600 mg/dL and volumes of 80, 8, and 1 nL. Calibration was carried out using multivariate partial least-squares (PLS) modeling with spectral data between 1180 and 940 cm<sup>−1</sup>. Best performance was achieved in the ATR experiments. For raw ATR spectra, the optimum standard error of prediction (SEP) of 13.3 mg/dL was ob- tained for the 8 nL sample series with subsequent 10-fold dilution. With respect to the coefficient of variation of the glucose assay, CV<sub>pred</sub>, we obtained a value of 3% for the 80 nL volume samples with spectral preprocessing using matrix protein absorption bands as an internal standard, 4% for the 8 nL samples, and 6% for the 1 nL samples with raw data. Spectral standardization resulted in significant improvement, especially for the 80 nL volume sample series. By contrast, the accuracy of the glucose assay for the 1 nL sample volume series could not be improved either by internal standardization or by considering the dry film areas for normalization, which we attribute to varying topographies of the dry films.

PDF Article
More Like This
Determination of glucose in whole blood samples by mid-infrared spectroscopy

Yoen-Joo Kim, Sangjoon Hahn, and Gilwon Yoon
Appl. Opt. 42(4) 745-749 (2003)

Hollow optical-fiber based infrared spectroscopy for measurement of blood glucose level by using multi-reflection prism

Saiko Kino, Suguru Omori, Takashi Katagiri, and Yuji Matsuura
Biomed. Opt. Express 7(2) 701-708 (2016)

Noninvasive glucose monitoring using mid-infrared absorption spectroscopy based on a few wavenumbers

Ryosuke Kasahara, Saiko Kino, Shunsuke Soyama, and Yuji Matsuura
Biomed. Opt. Express 9(1) 289-302 (2018)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.