Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 57,
  • Issue 11,
  • pp. 1432-1441
  • (2003)

Remote Detection of Heated Ethanol Plumes by Airborne Passive Fourier Transform Infrared Spectrometry

Not Accessible

Your library or personal account may give you access

Abstract

Methodology is developed for the automated detection of heated plumes of ethanol vapor with airborne passive Fourier transform infrared spectrometry. Positioned in a fixed-wing aircraft in a downward-looking mode, the spectrometer is used to detect ground sources of ethanol vapor from an altitude of 2000–3000 ft. Challenges to the use of this approach for the routine detection of chemical plumes include (1) the presence of a constantly changing background radiance as the aircraft flies, (2) the cost and complexity of collecting the data needed to train the classification algorithms used in implementing the plume detection, and (3) the need for rapid interferogram scans to minimize the ground area viewed per scan. To address these challenges, this work couples a novel ground-based data collection and training protocol with the use of signal processing and pattern recognition methods based on short sections of the interferogram data collected by the spectrometer. In the data collection, heated plumes of ethanol vapor are released from a portable emission stack and viewed by the spectrometer from ground level against a synthetic background designed to simulate a terrestrial radiance source. Classifiers trained with these data are subsequently tested with airborne data collected over a period of 2.5 years. Two classifier architectures are compared in this work: support vector machines (SVM) and piecewise linear discriminant analysis (PLDA). When applied to the airborne test data, the SVM classifiers perform best, failing to detect ethanol in only 8% of the cases in which it is present. False detections occur at a rate of less than 0.5%. The classifier performs well in spite of differences between the backgrounds associated with the ground-based and airborne data collections and the instrumental drift arising from the long time span of the data collection. Further improvements in classification performance are judged to require increased sophistication in the ground-based data collection in order to provide a better match to the infrared backgrounds observed from the air.

PDF Article
More Like This
Passive remote monitoring of chemical vapors by differential Fourier-transform infrared radiometry: results at a range of 1.5 km

Jean-Marc Thériault, Eldon Puckrin, François Bouffard, and Bernhard Déry
Appl. Opt. 43(6) 1425-1434 (2004)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.