Factors Affecting the Production of Fast Transient Signals in Single Shot Laser Ablation Inductively Coupled Plasma Mass Spectrometry

Not Accessible

Your library or personal account may give you access

Abstract

Low sample consumption and high achievable spatial resolution combine to make laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) an attractive direct sampling technique for the analysis of solids. These desirable characteristics are best realized when the laser ablation system is operated in a single-shot fashion, in which each laser pulse produces a transient analyte signal. The temporal width of a single-shot LA analyte transient is inversely related to the best achievable signal-to-noise ratio (S/N). Thus, production of fast transient signals is an important consideration in single-shot LA analyses. In this study we explore the effects on transient pulse width of ablation-cell volume, the diameter and length of tubing used to connect the ablation cell to the ICP, and the composition and flow rate of ablation-cell sweep gas. Minimization of ablation-cell volume and the length and diameter of the transfer tube was found to dramatically decrease the peak widths of transient signals. However, use of helium gas to sweep analyte particles from the ablation cell was found to significantly reduce the effect of cell volume on transient width. Use of a cell volume of 0.70 cm<sup>3</sup> and optimization of other instrumental parameters produced a transient sample pulse 85 ms in duration and limits of detection in the tens of femtograms range for single-shot laser-ablation events.

PDF Article
More Like This
Multielemental analysis of prehistoric animal teeth by laser-induced breakdown spectroscopy and laser ablation inductively coupled plasma mass spectrometry

Michaela Galiová, Jozef Kaiser, Francisco J. Fortes, Karel Novotný, Radomír Malina, Lubomír Prokeš, Aleš Hrdlička, Tomáš Vaculovič, Miriam Nývltová Fišáková, Jiří Svoboda, Viktor Kanický, and Javier J. Laserna
Appl. Opt. 49(13) C191-C199 (2010)

Rapid trace element analysis of microgram soft materials with cryogenic milling and laser ablation spectroscopy

Yuanchao Liu, Yi-Kong Hsieh, Conrad Wong, Irfan Ahmed, Rafay Ahmed, Muhammad Shehzad Khan, Richard Y. H. Cheung, Chu-Fang Wang, and Condon Lau
Appl. Opt. 59(26) 7752-7759 (2020)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved