Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 54,
  • Issue 5,
  • pp. 706-714
  • (2000)

Calibration Transfer in the Automated Detection of Acetone by Passive Fourier Transform Infrared Spectrometry

Not Accessible

Your library or personal account may give you access

Abstract

The qualitative determination of acetone is performed by passive Fourier transform infrared (FT-IR) spectrometry with data spanning two spectrometers. Digital filtering and piecewise linear discriminant analysis techniques are optimized and applied directly to short interferogram segments to eliminate background and instrument variation and then perform pattern recognition. Once optimized, this methodology classifies remote sensing data into categories representing the presence or absence of the analyte in an automated fashion. The addition to the training set of small numbers of interferogram data from a second spectrometer is evaluated in the creation of qualitative models robust with respect to differences between the instruments. Results of these experiments show that classification percentages averaged across all tested interferogram segments are improved from 76.2 ± 6.4% to 95.1 ± 2.2% with the addition of as few as 10 background interferograms collected in the field with the secondary instrument. The results also demonstrate that a broader, more optimal range of segments in the interferogram can be utilized when these background data are added from the secondary instrument. It is also found possible to standardize the data from the secondary instrument with blackbody background interferograms collected in the laboratory.

PDF Article
More Like This
Passive standoff detection of radiological products by Fourier-transform infrared radiometry

Eldon Puckrin and Jean-Marc Thériault
Opt. Lett. 29(12) 1375-1377 (2004)

Passive standoff detection of Bacillus subtilis aerosol by Fourier-transform infrared radiometry

Jean-Marc Thériault, Eldon Puckrin, and James O. Jensen
Appl. Opt. 42(33) 6696-6703 (2003)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.