Optimization of Instrumentation Precision and Wavelength Resolution for the Performance of NIR Calibrations of Sucrose in a Water-Cellulose Matrix

Not Accessible

Your library or personal account may give you access

Abstract

Instrumentation for near-infrared (NIR) spectroscopic applications should be optimized for the intended application. The influence of signal precision and wavelength resolution was considered for the application of the noninvasive assessment [NIR 700-1050 nm, partial least-squares (PLS) calibration] of the sugar content of fruit, with the use of a model system of sucrose solution on cellulose. The precision (as estimated at the maximum count of the spectrum) of an MMSI Zeiss spectrometer (Carl Zeiss Pty. Ltd.) was varied by altering the number of scans averaged per spectrum, as well as the signal level. Wavelength resolution was varied between 8 and 20nm (as estimated of the 912nm Ar peak) by adjustment of the entrance slit of a prototype spectrometer employing a Hamamatsu S4874Q photodiode array as the detector, constructed on an optical bench. PLS calibrations were developed from interactance spectra of 0-20% w/v sucrose solution soaked filter papers, and compared on the basis of standard error of cross-validation (SECV) and coefficient of correlation-validation (R<sub>v</sub>). The optimum measurement precision for calibration development was lower than expected at a coefficient of variation (CV) of 0.02 [signal-to-noise ratio (SNR) 5000:1]. Calibration performance was poorer at a resolution of < 8 nm full width at half-maximum (FWHM) in the NIR region, but not significantly different at resolutions of between 8 and 20nm. Further work is required to define the upper threshold of wavelength resolution. We conclude that instrumentation for the application of fruit sorting can have a relatively poor resolution, and can afford to operate at signal-to-noise levels considered low for a photodiode array detector. Index Headings: Coefficient of variation; NIR spectroscopy; Reflectance; Transmission; Chemometrics; Instrument design.

PDF Article
More Like This
Estimation precision for a normalized response matrix in linear polarization calibration

Xinkai Li, Pengfei Miao, Lingping He, Heng Shen, Xiaodong Wang, Bowen Gong, Xingjun Gao, and Bo Chen
Appl. Opt. 61(23) 6736-6743 (2022)

Far-infrared spectroscopy of the troposphere: instrument description and calibration performance

Harri Latvakoski, Martin G. Mlynczak, David G. Johnson, Richard P. Cageao, David P. Kratz, and Kendall Johnson
Appl. Opt. 52(2) 264-273 (2013)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.