Abstract
An experimental system to investigate the feasibility of using laser Raman spectroscopy to detect stack gas pollutants is described. With spontaneous Raman spectroscopy, one unit is capable of measuring all gas species simultaneously and, when applied to a continuous emissions monitoring (CEM) system, could both simplify it and improve reliability. Minimum detectabilities with the use of this weak light scattering process were determined for the three primary pollutants from coal-based power plants: carbon monoxide (CO), sulfur dioxide (SO2), and nitric oxide (NO). A frequency-doubled, pulsed Nd:YAG laser was used to excite the test gas held in a sample cell. A charge-coupled device connected to a spectrometer was used as the detection system, providing complete spectral information. A set of experiments was carried out for different concentrations of the three test gas species. With a 200-s integration time, the following minimum detectability limits were obtained: 100 ppm for SO , 250 ppm for CO, and 250 ppm for NO. A mixture of all three pollutants in a base of N2 was made to simulate typical stack gas mixtures. Baseline strength and associated shot noise are more severe when gas mixtures are being analyzed. One possible explanation is the broad-band fluorescence of NO2 , perhaps produced pho2 tolytically. System modifications to improve minimum detectabilities are discussed.
PDF Article
More Like This
Cited By
You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.
Contact your librarian or system administrator
or