Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 51,
  • Issue 1,
  • pp. 68-73
  • (1997)

Fused-Silica-Aperture Thermospray Sample Introduction into Axially Viewed Inductively Coupled Plasma-Atomic Emission Spectrometry

Not Accessible

Your library or personal account may give you access

Abstract

Axially viewed inductively coupled plasma-atomic emission spectrometry (ICP-AES) has encountered a resurgence in popularity over the past few years. It has been demonstrated that 5- to 10-fold improvements in limits of detection (LODs) can be obtained with axial viewing compared to conventional side-on-viewed ICP-AES. In this report, the coupling of fused-silica-aperture thermospray (FSApT)-based sample introduction with axially viewed ICP-AES is reported, in order to combine the properties of increased sample transport and reduced LODs for FSApT with the improved detection power of axially viewed ICP-AES. When FSApT was used with the standard axial torch having a large-diameter (2.3-mm) injector, high signal and background relative standard deviations (RSDs) resulted, as compared to results for pneumatic nebulization, limiting the LOD improvements obtained with FSApT. Smaller injectors (0.8-mm and 1.5-mm i.d.) allowed RSDs for FSApT that were similar to pneumatic sample introduction levels, and larger LOD improvements (10 X ) resulted. Data for FSApT with axially viewed ICP-AES were also compared with data for FSApT with side-onviewed ICP-AES, and axial viewing averaged an improvement of only a factor of 2. This small level of improvement suggests that the optical system for the axial system is not optimized for use with high-performance sample introduction. On the basis of improvement factors for FSApT with side-on viewing, FSApT with axially viewed ICP-AES averages LODs that are about 73 times better than those for the conventional side-on-viewed ICP-AES with pneumatic nebulization.

PDF Article
More Like This
Optimized condition for etching fused-silica phase gratings with inductively coupled plasma technology

Shunquan Wang, Changhe Zhou, Huayi Ru, and Yanyan Zhang
Appl. Opt. 44(21) 4429-4434 (2005)

Multielemental analysis of prehistoric animal teeth by laser-induced breakdown spectroscopy and laser ablation inductively coupled plasma mass spectrometry

Michaela Galiová, Jozef Kaiser, Francisco J. Fortes, Karel Novotný, Radomír Malina, Lubomír Prokeš, Aleš Hrdlička, Tomáš Vaculovič, Miriam Nývltová Fišáková, Jiří Svoboda, Viktor Kanický, and Javier J. Laserna
Appl. Opt. 49(13) C191-C199 (2010)

Detection of trace phosphorus in water by plasma amplification laser-induced breakdown spectroscopy

Xinyan Yang, Xin Wang, Xi Wang, Biyi Wang, Dongdong Li, Xu Zhang, Hongmei Ren, Zhengbo Qin, Zhengxian Zhou, and Xianfeng Zheng
Opt. Express 31(24) 40345-40351 (2023)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.