Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 49,
  • Issue 6,
  • pp. 825-833
  • (1995)

Evaluation of the Potential of a Charge-Injection Device for DNA Sequencing by Multiplexed Capillary Electrophoresis

Not Accessible

Your library or personal account may give you access

Abstract

Despite the rapid growth in the use of imaging detectors in spectroscopy, the charge-injection device (CID) has unique features that have not been fully exploited. The advantages of the CID as a two-dimensional array detector for laser-induced fluorescence detection in highly multiplexed capillary electrophoresis are evaluated. In such a system, the CID maintains both high sensitivity and high sampling rate, which are usually difficult to achieve simultaneously with other array detectors. Applying the electronic windowing function significantly improves the scan rate and greatly reduces the volume of data generated. With 1-s exposure time and 488-nm excitation, the detection limit of the system is 10<sup>-12</sup> M fluorescein with the device cryogenically cooled and 10<sup>-11</sup> M fluorescein at ambient temperature. The low dark current of the CID imager allows operation at room temperature without significantly affecting sensitivity when combined with moderate laser powers. We demonstrate that the CID is well suited for high-speed, high-throughput DNA sequencing based on multiplexed capillary electrophoresis with on-column laser-induced fluorescence detection.

PDF Article
More Like This
Fluorescence monitoring of microchip capillary electrophoresis separation with monolithically integrated waveguides

Chaitanya Dongre, Ronald Dekker, Hugo J. W. M. Hoekstra, Markus Pollnau, Rebeca Martinez-Vazquez, Roberto Osellame, Giulio Cerullo, Roberta Ramponi, Rob van Weeghel, Geert A. J. Besselink, and Hans H. van den Vlekkert
Opt. Lett. 33(21) 2503-2505 (2008)

Infrared charge-injection-device array performance at low background

C. R. McCreight and J. H. Goebel
Appl. Opt. 20(18) 3189-3196 (1981)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.