Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 49,
  • Issue 12,
  • pp. 1729-1736
  • (1995)

Scientifically Operated CCD-Based Spectroscopic System for High-Precision Spectrometric Determinations of Seawater

Not Accessible

Your library or personal account may give you access

Abstract

The application of an aberration-corrected imaging spectrograph with the use of fiber-optic inputs and a charge-coupled device detector to produce a sensitive, flexible, and rugged spectroscopic system capable of employment in remote sensing and field applications is presented. This investigation focuses on the optical system design, detector characteristics, and modes of operation that will result in a field instrument capable of both sensitive fluorescence and high-precision absorbance measurements. Evaluation of the optical system used the spectroscopic determination of seawater pH as the test case. Spectral measurements were made with the use of thymol blue as a pH indicator for absorbance and 7-hydroxy-coumarin as the fluorescence pH indicator. This system displayed excellent precision for both absorbance and fluorescence analyses; RSDs for absorbance and fluorescence of ±0.00065 and ±0.0015 in pH, respectively, were experimentally obtained. These findings, along with the advantages of the area array detector to provide simultaneous multiwavelength, multianalyte spectral analysis in a single, rugged optical system, make a strong case for the application of scientifically operated solid-state detector systems to remote sensing and field instrumentation.

PDF Article
More Like This
Development and initial calibration of a portable laser-induced fluorescence system used for in situ measurements of trace plastics and dissolved organic compounds in seawater and the Gulf of Mexico

Vasanthi Sivaprakasam, Robert F. Shannon, Caiyan Luo, Paula G. Coble, Jennifer R. Boehme, and Dennis K. Killinger
Appl. Opt. 42(33) 6747-6756 (2003)

Ratiometric optical sensor for high-resolution imaging of pH with low cross-talk

Zike Jiang, Jiantao Chen, Jiewei Du, Tiesheng Liu, Xiaofeng Li, Huibin Yu, Qi Zhang, Yimeng Hu, Fengchen Liu, Xinsheng Yu, and Zhonghai Zhou
Appl. Opt. 57(34) 9922-9928 (2018)

System analysis of CCD-based bar code readers

David Tsi, Emanuel Marom, Joseph Katz, and Jerome Swartz
Appl. Opt. 32(19) 3504-3512 (1993)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.