Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 47,
  • Issue 7,
  • pp. 1007-1014
  • (1993)

Wavelength Calibration Methods for Low-Resolution Photodiode Array Spectrometers

Not Accessible

Your library or personal account may give you access

Abstract

A wavelength calibration method for low-resolution diode array spectrometers is described. The method was developed for routine calibration of 0.1-meter-focal-distance spectrometers having 35- or 38-element silicon diode arrays, normally operated in the 340-700 nm spectral range. Each diode of the array is approximately 1 mm wide, giving an instrumental bandwidth of ~10 nm per diode. The calibration method requires two well-separated monochromatic spectral lines, their central image locations on the array, and the grating groove frequency. This method is compared with nonlinear regression (least-squares) methods, with multiple calibration lines fitted to quadratic or cubic polynomials. The predictive accuracy of the wavelength-pair method compares favorably with the regression methods. A calibration accuracy of ~±1 nm is expected for the instruments considered here. The method described could, in principle, be applied to instruments with higher resolution, such as those having self-scanned photodiode arrays with 25-μm or 50-μm-wide pixels. For such instruments, however, a large number of calibration lines should be resolved. In this case, the regression method, which averages diode position measurement errors, is probably more accurate. The wavelength-pair method is most useful for low-resolution instruments, for which regression methods may not be practical.

PDF Article
More Like This
Accurate wavelength calibration method for compact CCD spectrometer

Y. C. Sun, C. Huang, G. Xia, S. Q. Jin, and H. B. Lu
J. Opt. Soc. Am. A 34(4) 498-505 (2017)

Evaluation of a Hadamard-coded photodiode-array spectrometer under low illumination

Joseph L. Robichaud, Wallace K. Wong, and Roger A. Van Tassel
Appl. Opt. 33(1) 75-81 (1994)

Wavelength calibration methods in laser wavelength measurement

Liang Yuan and Lirong Qiu
Appl. Opt. 60(15) 4315-4324 (2021)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.