Interpreting IR Difference Spectra

Not Accessible

Your library or personal account may give you access

Abstract

From the evaluation of sample difference spectra based on Gaussian "model" peaks with known peak characteristics, it is shown that interpretation of some parameters from difference spectra, resulting from the ratioing or subtraction of a poor background spectra, may be inaccurate or misleading. Difference spectra of this type are commonly observed with the use of techniques such as subtractively normalized interfacial Fourier transform infrared spectroscopy (SNIFTIRS), electrochemically modulated infrared reflectance spectroscopy (EMIRS), or similar infrared spectroelectrochemical techniques, as well as some microsample analyses, studies of biochemical processes, and infrared astronomical observations, to name just a few examples. A mathematical evaluation of the problem is offered to demonstrate what information may realistically be gained from the characteristics of difference spectra. It is shown that in the worst case, where frequency, intensity, and peak width are all changing due to some perturbation of the sample (e.g., from temperature, or surface potential changes between background and sample spectra, etc.), even a qualitative interpretation may not be possible. In many practical cases, however, we show that at least a qualitative interpretation of the data can be obtained from difference spectra. Spectroelectrochemical applications for the calculations shown here are presented as examples, although these results impact a wider range of applications.

PDF Article
More Like This
Water cluster interpretation of IR absorption spectra in the 8–14-μm wavelength region

S. H. Suck, J. L. Kassner, and Y. Yamaguchi
Appl. Opt. 18(15) 2609-2617 (1979)

Interpretation of reflection and transmission spectra for thin films: transmission

Kiyoshi Yamamoto and Hatsuo Ishida
Appl. Opt. 34(21) 4177-4185 (1995)

Interpretation of ir scanning radiometer data

A. W. Kamp
Appl. Opt. 18(1) 82-84 (1979)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.