A Method for the Determination of the Zero-Path-Difference Position in a Fourier Transform Infrared Spectrometer: Application to Magnetic Vibrational Circular Dichroism

Not Accessible

Your library or personal account may give you access

Abstract

Some modern FT-IR spectrometers, without a white light source, use a pre-scan of the signal to determine the zero path difference for purposes of scan initialization. The interferograms in vibrational circular dichroism (VCD) and other low signal-to-noise ratio experiments have little or no centerburst, which can cause problems. This can lead to wasted data collections and to instabilities between successively collected blocks of scans. In this modification, a PbSe detector is used to detect frequencies above 2200 cm<sup>−1</sup> extracted from a small fraction of the beam. This near-IR signal is then added to the demodulated differential signal to enable the instrument to initialize scans. Since, in this example, the VCD spectra are typically obtained below 2000 cm<sup>−1</sup>, there is no spectral interference between the two detector signals. However, use of two signals from different detectors can lead to phase problems, which have been solved with the use of polarization calibration methods. As an example, construction of such a modified spectrometer for magnetic VCD measurement is described in detail. At 0.5 cm<sup>−1</sup> resolution, these modulated spectra evidence resolution of the rotational structure in the bands. Such data were unobservable with the unmodified instrument.

PDF Article
More Like This
A picosecond time-resolved vibrational circular dichroism spectrometer

Mathias Bonmarin and Jan Helbing
Opt. Lett. 33(18) 2086-2088 (2008)

Multichannel Fourier-transform infrared spectrometer

Mamoru Hashimoto and Satoshi Kawata
Appl. Opt. 31(28) 6096-6101 (1992)

Flight qualification of a diode laser for path difference determination of a high-resolution Fourier transform spectrometer

Giovanni Bianchini, Michela Lanfranchi, and Ugo Cortesi
Appl. Opt. 39(6) 962-965 (2000)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.