New Methodology to Obtain a Calibration Model for Noninvasive Near-Infrared Blood Glucose Monitoring

Not Accessible

Your library or personal account may give you access

Abstract

This paper reports new methodology to obtain a calibration model for noninvasive blood glucose monitoring using diffuse reflectance near-infrared (NIR) spectroscopy. Conventional studies of noninvasive blood glucose monitoring with NIR spectroscopy use a calibration model developed by <i>in vivo</i> experimental data sets. In order to create a calibration model, we have used a numerical simulation of light propagation in skin tissue to obtain simulated NIR diffuse reflectance spectra. The numerical simulation method enables us to design parameters affecting the prediction of blood glucose levels and their variation ranges for a data set to create a calibration model using multivariate analysis without any <i>in vivo</i> experiments in advance. By designing the parameters and their variation ranges appropriately, we can prevent a calibration model from chance temporal correlations that are often observed in conventional studies using NIR spectroscopy. The calibration model (regression coefficient vector) obtained by the numerical simulation has a characteristic positive peak at the wavelength around 1600 nm. This characteristic feature of the regression coefficient vector is very similar to those obtained by our previous <i>in vitro</i> and <i>in vivo</i> experimental studies. This positive peak at around 1600 nm also corresponds to the characteristic absorption band of glucose. The present study has reinforced that the characteristic absorbance of glucose at around 1600 nm is useful to predict the blood glucose level by diffuse reflectance NIR spectroscopy. We have validated this new calibration methodology using <i>in vivo</i> experiments. As a result, we obtained a coefficient of determination, <i>r</i><sup>2</sup>, of 0.87 and a standard error of prediction (SEP) of 12.3 mg/dL between the predicted blood glucose levels and the reference blood glucose levels for all the experiments we have conducted. These results of <i>in vivo</i> experiments indicate that if the parameters and their vibration ranges are appropriately taken into account in a numerical simulation, the new calibration methodology provides us with a very good calibration model that can predict blood glucose levels with small errors without conducting any experiments in advance to create a calibration model for each individual patient. This new calibration methodology using numerical simulation has promising potential for NIR spectroscopy, especially for noninvasive blood glucose monitoring.

PDF Article
More Like This
Noninvasive glucose monitoring using mid-infrared absorption spectroscopy based on a few wavenumbers

Ryosuke Kasahara, Saiko Kino, Shunsuke Soyama, and Yuji Matsuura
Biomed. Opt. Express 9(1) 289-302 (2018)

Noninvasive in vivo glucose sensing on human subjects using mid-infrared light

Sabbir Liakat, Kevin A. Bors, Laura Xu, Callie M. Woods, Jessica Doyle, and Claire F. Gmachl
Biomed. Opt. Express 5(7) 2397-2404 (2014)

High-accuracy noninvasive continuous glucose monitoring using OCT angiography-purified blood scattering signals in human skin

Mengqin Gao, Dayou Guo, Jiahao Wang, Yizhou Tan, Kaiyuan Liu, Lei Gao, Yulei Zhang, Zhihua Ding, Ying Gu, and Peng Li
Biomed. Opt. Express 15(2) 991-1003 (2024)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved