Automated Detection of Chemical Vapors by Pattern Recognition Analysis of Passive Multispectral Infrared Remote Sensing Imaging Data

Not Accessible

Your library or personal account may give you access

Abstract

Pattern recognition methods are developed for the automated interpretation of passive multispectral imaging data collected from an airborne platform. Through the use of an infrared line scanner equipped with 14 spectral bandpass filters, passive infrared images are collected of an ammonia plant within a nitrogen fertilizer facility. Piecewise linear discriminant analysis is used to implement an automated algorithm for the detection of scene pixels that correspond to chemical vapor signatures. A separate classifier is used to detect the presence of hot carbon dioxide (CO<sub>2</sub>) within the images. In the assembly of training and prediction data for the development of both classifiers, the <i>K</i>-means clustering algorithm is used together with knowledge of the site to assign pixels to the plume/nonplume and CO<sub>2</sub>/non-CO<sub>2</sub> categories. The effects of temperature variation within the imaged scene are removed from the data through the use of an algorithm for separating the contributions of temperature and emissivity to the Planck equation. Averaged across four data runs containing a total of 3.5 million pixels, the resulting discriminants are observed to detect approximately 91% of the plume pixels while achieving a false detection rate of less than 0.01%. The corresponding performance criteria for the CO<sub>2</sub> classifier are a successful detection of approximately 94% of the pixels with a CO<sub>2</sub> signature and a false detection rate of less than 0.7%. The robustness of the CO<sub>2</sub> classifier is further enhanced through the adoption of a probability-based classification rule.

PDF Article
More Like This
Passive remote monitoring of chemical vapors by differential Fourier-transform infrared radiometry: results at a range of 1.5 km

Jean-Marc Thériault, Eldon Puckrin, François Bouffard, and Bernhard Déry
Appl. Opt. 43(6) 1425-1434 (2004)

Comparing analysis of multispectral and polarimetric imaging for mid-infrared detection blindness condition

Huijie Zhao, Yansong Li, Guorui Jia, Na Li, Zheng Ji, and Jianrong Gu
Appl. Opt. 57(24) 6840-6850 (2018)

Tunable Fabry–Perot etalon-based long-wavelength infrared imaging spectroradiometer

William J. Marinelli, Christopher M. Gittins, Alan H. Gelb, and B. David Green
Appl. Opt. 38(12) 2594-2604 (1999)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved