Influence of Gas Sampling on Analyte Transport within the ICP and Ion Sampling for ICP-MS Studied Using Individual, Isolated Sample Droplets

Not Accessible

Your library or personal account may give you access

Abstract

The effect of gas flow entrainment on the gas sampling, ion sampling, and ion detection processes in inductively coupled plasma mass spectrometry (ICP-MS) has been investigated. Isolated, single droplets of sample from a monodisperse dried microparticulate injector (MDMI) were used in conjunction with time-resolved ICP-MS, photographs of ion cloud movement, and time-gated imaging using a gateable, intensified charge-coupled device (ICCD) detector mounted on an imaging spectrometer. The results indicate that gas flow entrainment into the sampling orifice can have a significant effect on the plasma gas velocities as far as 7 mm from the sampling orifice. The effects are most pronounced within 3 mm of the sampling orifice. The trends in these results are consistent with theoretical calculations. Photographic images show that plasma gas initially as far as 3 mm off axis adopts a curved path into the sampling orifice. Time-resolved emission images of Sr<sup>+</sup> ion clouds approaching the sampling orifice demonstrate the entrainment process and significant distortion of the ion cloud as it flows into the sampling orifice. Spatial maps of La<sup>+</sup> ICP-MS signals were acquired as a function of distance from the vaporization point and distance from the plasma axis. The results suggest that gas entrainment has a significant effect on the spatial path of ions in the plasma and that accurate radially resolved spatial mapping of plasmas using mass spectrometry may not be possible. The widths of radially resolved La<sup>+</sup> ICP-MS signal peaks do not change significantly when ions are sampled 2 mm from the vaporization point compared to 5 mm away. In contrast, ICP-MS signals measured on axis as a function of time clearly show broadening due to diffusion. These observations suggest that some detected ions may have originated from offaxis locations in the plasma.

PDF Article
More Like This
Multielemental analysis of prehistoric animal teeth by laser-induced breakdown spectroscopy and laser ablation inductively coupled plasma mass spectrometry

Michaela Galiová, Jozef Kaiser, Francisco J. Fortes, Karel Novotný, Radomír Malina, Lubomír Prokeš, Aleš Hrdlička, Tomáš Vaculovič, Miriam Nývltová Fišáková, Jiří Svoboda, Viktor Kanický, and Javier J. Laserna
Appl. Opt. 49(13) C191-C199 (2010)

Development of a remote laser-induced breakdown spectroscopy system for investigation of calcified tissue samples

Aleš Hrdlička, Lubomír Prokeš, Alice Staňková, Karel Novotný, Anna Vitešníková, Viktor Kanický, Vítězslav Otruba, Jozef Kaiser, Jan Novotný, Radomír Malina, and Kateřina Páleníková
Appl. Opt. 49(13) C16-C20 (2010)

Elemental composition analysis of granite rocks using LIBS and LA-TOF-MS

Zeshan Adeel Umar, Nasar Ahmed, Rizwan Ahmed, Usman Liaqat, and Muhammad Aslam Baig
Appl. Opt. 57(18) 4985-4991 (2018)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.