Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 53,
  • Issue 3,
  • pp. 332-338
  • (1999)

Optical Spectroscopic Method for in Vivo Measurement of Cardiac Myoglobin Oxygen Saturation

Not Accessible

Your library or personal account may give you access

Abstract

A fiber-optic-based spectrophotometer was developed to acquire optical reflectance spectra from a living dog heart. A bullseye concentric optical probe with a 3 mm source-to-detector fiber separation was designed to obtain a 1.5 mm average tissue depth of light penetration. Spectra were analyzed in the near-infrared region from 660 to 840 nm. Myoglobin oxygen saturation was determined by partial least-squares analysis using a calibration spectral data set developed in vitro. Comparison of in vivo and in vitro spectra by Mahalanobis distance and residual ratio tests demonstrated good similarity, justifying use of partial least-squares analysis. Coronary perfusion with an oxygenated blood substitute, Fluosol , was used to demonstrate that hemoglobin had little effect on the analysis. An increase in myoglobin saturation of 5% was noted when the animals were changed from inspired room air to 100% oxygen. Occlusion of the coronary artery resulted in prompt decrease in myoglobin saturation, and release of the occlusion was followed by rapid increase in saturation to a value above baseline. These experiments demonstrate that it is feasible to use partial least-squares analysis of near-infrared reflectance spectra to determine myoglobin saturation in the blood-perfused, beating heart.

PDF Article
More Like This
Effect of hemoglobin extinction spectra on optical spectroscopic measurements of blood oxygen saturation

Arjen Amelink, Theo Christiaanse, and Henricus J. C. M. Sterenborg
Opt. Lett. 34(10) 1525-1527 (2009)

Measurement of oxygen saturation in the retina with a spectroscopic sensitive multi aperture camera

Jessica C. Ramella-Roman, Scott A. Mathews, Haryipria Kandimalla, Afshin Nabili, Donald D. Duncan, Salvatore A. D’Anna, Syed Mahmood Shah, and Quan Dong Nguyen
Opt. Express 16(9) 6170-6182 (2008)

Quantitative measurement of muscle oxygen saturation without influence from skin and fat using continuous-wave near infrared spectroscopy

Ye Yang, Olusola O. Soyemi, Peter J. Scott, Michelle R. Landry, Stuart M. C. Lee, Leah Stroud, and Babs R. Soller
Opt. Express 15(21) 13715-13730 (2007)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.