Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Laparoscopic diffuse reflectance spectroscopy of an underlying tubular inclusion: a phantom study

Not Accessible

Your library or personal account may give you access

Abstract

We demonstrate diffuse reflectance spectroscopy (DRS) of a subsurface tubular inclusion by using a fiber probe having a single source–detector pair attached to a laparoscopic bipolar device. A forward model was also developed for DRS sensing of an underlying long absorbing tubular inclusion set in parallel to the tissue surface, normal to the line of sight of the source–detector pair, and equidistant from the source and the detector. The model agreed with measurements performed at 500 nm and using a 10 mm source–detector separation (SDS) on an aqueous tissue phantom embedding a tubing of 2 or 4 mm inner diameter that contained 9.1% to 33.3% red dye at a depth of up to 11.5 mm. When tested on solid phantoms using the 10 mm SDS, a tubular inclusion of $ \ge 3\;{\rm mm}$ inner diameter containing 0.05% red dye at a background absorption coefficient of $ 0.021\;{\rm mm}^{-1} $ caused $ \ge 8\% $ change of the signal at 500 nm versus the baseline when the inclusion was shallower than 5 mm. When assessed on avian muscle tissue having a 4 mm tubular inclusion embedded at an edge depth of 2 mm, DRS with the 10 mm SDS differentiated the following contents of the inclusion: 33.3% red dye (mimicking blood), 33.3% green dye, 33.3% yellow dye (mimicking bile), water (mimicking urine), and air.

© 2019 Optical Society of America

Full Article  |  PDF Article
More Like This
Diffuse reflectance spectroscopy-enhanced drill for bone boundary detection

Matthieu Duperron, Konstantin Grygoryev, Gerard Nunan, Cormac Eason, Jacqueline Gunther, Ray Burke, Kevin Manley, and Peter O’brien
Biomed. Opt. Express 10(2) 961-977 (2019)

Tissue-mimicking phantom materials with tunable optical properties suitable for assessment of diffuse reflectance spectroscopy during electrosurgery

Sara Azizian Amiri, Pieter Van Berckel, Marco Lai, Jenny Dankelman, and Benno H. W. Hendriks
Biomed. Opt. Express 13(5) 2616-2643 (2022)

Blood vessel detection, localization and estimation using a smart laparoscopic grasper: a Monte Carlo study

Amal Chaturvedi, Shetha A. Shukair, Paul Le Rolland, Mayank Vijayvergia, Jonathan W. Gunn, and Hariharan Subramanian
Biomed. Opt. Express 9(5) 2027-2040 (2018)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (11)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (39)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.