Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Calibration algorithm for cooled mid-infrared systems considering the influences of ambient temperature and integration time

Not Accessible

Your library or personal account may give you access

Abstract

Midwave infrared systems with cooled detectors are generally used for high-precision or quantitative measurement, such as radiometry and thermometry. As a basis of these applications, radiometric calibration aims to obtain the relationship between the infrared images and the incident radiant flux generated by the scene or targets. Conventional radiometric calibration algorithms do not take the influences of integration and ambient temperature into consideration. As a consequence, the accuracy of calibration deteriorates whenever the temperature or the integration time varies. To solve this problem, we analyzed the effects of integration time and ambient temperature on coefficients of the radiometric calibration formula by theoretical and experimental analysis. Then, a radiometric calibration method is deduced to remove the variation of integration time and ambient temperature on the accuracy of calibration and radiometry. Several radiometric calibration experiments were conducted using a midwave infrared camera inside a chamber with controllable temperature. The results indicate that the proposed calibration algorithm is more effective and accurate, compared with conventional calibration methods, in complicated working conditions with variable integration times and ambient temperatures.

© 2019 Optical Society of America

Full Article  |  PDF Article
More Like This
Method to remove the effect of ambient temperature on radiometric calibration

Chang Songtao, Zhang Yaoyu, Sun Zhiyuan, and Li Min
Appl. Opt. 53(27) 6274-6279 (2014)

Global optimization radiometric calibration method for an infrared system with a wide dynamic range

Ting Li, Xuefeng Lai, Sujun Li, Yucheng Xia, Jinmei Zhou, and Sheng Liao
Appl. Opt. 63(2) 406-414 (2024)

Ambient temperature-independent dual-band mid-infrared radiation thermometry

You Lü, Xin He, Zhong-Hui Wei, Zhi-Yuan Sun, and Song-Tao Chang
Appl. Opt. 55(9) 2169-2174 (2016)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (9)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (1)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (17)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.