Quantum efficiency measurement of an x-ray charge-coupled device by means of an x-ray generator monochromatized over the 0.2–1.2 keV spectral region

Not Accessible

Your library or personal account may give you access

Abstract

The Atomic Energy Commission has been developing an x-ray calibration laboratory for several years close to the Laser MégaJoule Facility mainly to calibrate x-ray cameras. Based on x-ray generators, great effort is being carried out to obtain x-ray monochromatic sources over the 0.1–10 keV spectral range. Moreover, their routine availability is a prerequisite while getting reduced uncertainties. To achieve this purpose, two x-ray monochromators have been recently developed, the former running below 1.5 keV and the latter in the harder x-ray region. The work presented in this paper constitutes, to the best of our knowledge, the first radiometric calibration of an x-ray camera, namely, a charge-coupled device (CCD). The CCD is thin and back illuminated with a 1300×1340 pixel, 20μm×20μm area. It has been calibrated by means of our soft x-ray monochromator based on Rowland circle geometry. This apparatus is able to take on board simultaneously two detectors under vacuum: the CCD to be calibrated and a silicon drift spectrometer (SDD), which acts as a reference detector to obtain the x-ray monochromatic intensity. An internal specific vacuum manipulator allows putting successively each detector in front of the scanning exit slit. Quantum efficiency (QE) of the CCD has thus been measured over the 0.2–1.2 keV region, due to the reference SDD. The latter was previously calibrated on the same monochromator by cross-calibration with another SDD calibrated at the Physikalisch-Technische Bundesanstalt (PTB) Radiometry Laboratory, on the synchrotron radiation facility BESSY. QE measurements are then compared to the CCD manufacturer’s model and with previous ones performed on the same camera by means of our hard x-ray monochromator (2–10 keV). Comparison of these results with further PTB efficiency calibration of the reference SDD used to calibrate the CCD is discussed and allows concluding definitively about the validity of measurements performed by our x-ray monochromators.

© 2018 Optical Society of America

Full Article  |  PDF Article
More Like This
Characterization of a charge-coupled-device detector in the 1100–0.14-nm (1-eV to 9-keV) spectral region

Luca Poletto, Alessio Boscolo, and Giuseppe Tondello
Appl. Opt. 38(1) 29-36 (1999)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (6)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (1)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (2)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.