Impact of partial coherence on the apparent optical transfer function derived from the response to amplitude edges

Not Accessible

Your library or personal account may give you access

Abstract

We present an investigation of the impact of partial coherence on optical imaging systems with the focus on whole slide imaging (WSI) systems for digital pathology. The investigation is based on the analysis of the edge response of the optical system, which gives rise to an apparent optical transfer function (OTF) that can be linked to two elementary complex functions Q and U. The function Q is directly related to the transmission cross coefficient (TCC) and can be identified with the performance function first introduced by Kintner and Sillitto. The function U depends on the TCC in a more involved way. When there are no aberrations the Q-function corresponds to the real part of the apparent OTF and the U function to the imaginary part of the apparent OTF. Close to the incoherent limit the effect of the U function is a mere shift of the edge compared to the fully incoherent case. We propose a new expression for the dependence of the depth of focus (DOF) on spatial frequency and on the partial coherence factor σ, and validate it by simulation. Partial coherence effects are investigated experimentally on a WSI system with a compact LED-based Köhler illumination unit with variable condenser NA. This unit incorporates a top hat diffuser for providing a reasonably uniform illumination field, with variations below 10% across the imaged field of view. The measurements of the apparent through-focus OTF derived from edges on a custom resolution chart for different σ were substantially in agreement with the simulations. Finding an optimal value for σ is not straightforward as lateral resolution and the level of edge ringing improve with increasing σ, whereas edge contrast and DOF improve with decreasing σ. We assess that the trade-off for the particular application of WSI systems for digital pathology is optimized for a σ value in the range of 0.55–0.75.

© 2017 Optical Society of America

Full Article  |  PDF Article
More Like This
Optical quality assessment of whole slide imaging systems for digital pathology

S. Mojtaba Shakeri, Bas Hulsken, Lucas J. van Vliet, and Sjoerd Stallinga
Opt. Express 23(2) 1319-1336 (2015)

Effect of spatial coherence on knife-edge measurements of detector modulation transfer function

Miles N. Wernick and G. Michael Morris
Appl. Opt. 33(25) 5906-5913 (1994)

Effects of misalignment errors on the optical transfer functions of synthetic aperture telescopes

Jorge L. Flores, Marija Strojnik, Gonzalo Páez, and Guillermo García-Torales
Appl. Opt. 43(32) 5926-5932 (2004)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (18)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (39)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved