Abstract
A vibration monitoring system based on light intensity measurement has been constructed, and the designed accelerometer is based on steel cantilever frame and dual fiber Bragg gratings (FBGs). By using numerical simulations for the dual FBGs, the dependence relationship of the area of main lobes on the difference of initial central wavelengths is obtained and the most optimal choice for the initial value and the vibration amplitude of the difference of central wavelengths of two FBGs is suggested. The vibration monitoring experiments are finished, and the measured data are identical to the simulated results.
© 2013 Optical Society of America
Full Article | PDF ArticleMore Like This
Yuntian Teng, Bingbing Zhang, Xiaoyong Fan, Jiemei Ma, and Zhongchao Qiu
Appl. Opt. 61(25) 7521-7531 (2022)
XiaoMei Wang, RuiMing Zhang, Xiaoyong Fan, YunTian Teng, and YiXiang Tang
Appl. Opt. 62(27) 7254-7262 (2023)
Kuo-Chih Chuang, Chien-Ching Ma, and Hwa-Chun Wang
Appl. Opt. 55(9) 2426-2434 (2016)