Probe alignment and design issues of microelectromechanical system based optical coherence tomography endoscopic imaging

Not Accessible

Your library or personal account may give you access

Abstract

Endoscopic optical coherence tomography (OCT) imaging has been demonstrated using microelectromechanical system (MEMS) technology by several research groups. The focus of this work is to study how the OCT imaging performance is affected by the radius of curvature of MEMS mirrors as well as the optical alignment accuracy inside small imaging probes. The goal of this study is to provide guidance for assembly tolerance and design optimization of OCT endoscopic probes. Gaussian beam propagation is used for theoretical analysis which is confirmed by optical simulation and verified experimentally with a time-domain OCT system as well. It has been found that the OCT imaging is very sensitive to the distance from the fiber end to the gradient-index (GRIN) lens, which needs to be controlled within 0.1 mm to achieve working distance (WD) longer than 3.5 mm and lateral resolution around 25 μm. The impact on image quality of the MEMS mirror is negligible if the radius of curvature of the mirror surface is greater than 200 mm. In addition, we studied the astigmatism introduced by cylindrical plastic tubing; the maximum astigmatism ratio is 1.1 when the WD is around 2.5 mm.

© 2013 Optical Society of America

Full Article  |  PDF Article
More Like This
In vivo endoscopic optical coherence tomography by use of a rotational microelectromechanical system probe

Peter H. Tran, David S. Mukai, Matthew Brenner, and Zhongping Chen
Opt. Lett. 29(11) 1236-1238 (2004)

Common-path optical coherence tomography using a microelectromechanical-system-based endoscopic probe

Donglin Wang, Can Duan, Xiaoyang Zhang, Zhao Yun, Antonio Pozzi, and Huikai Xie
Appl. Opt. 55(25) 6930-6935 (2016)

Circumferential-scanning endoscopic optical coherence tomography probe based on a circular array of six 2-axis MEMS mirrors

Site Luo, Dan Wang, Jianyu Tang, Liang Zhou, Can Duan, Donglin Wang, Hao Liu, Yu Zhu, Guoxing Li, Hui Zhao, Yuqing Wu, Xin An, Xinling Li, Yabing Liu, Li Huo, and Huikai Xie
Biomed. Opt. Express 9(5) 2104-2114 (2018)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (7)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (23)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved