Abstract
A new method for the retrieval of the spectral refractive indices of micrometer-sized particles from infrared aerosol extinction spectra has been developed. With this method we use a classical damped harmonic-oscillator model of molecular absorption in conjunction with Mie scattering to model extinction spectra, which we then fit to the measurements using a numerical optimal estimation algorithm. The main advantage of this method over the more traditional Kramers–Kronig approach is that it allows the full complex refractive-index spectra, along with the parameters of the particle size distribution, to be retrieved from a single extinction spectrum. The retrieval scheme has been extensively characterized and has been found to provide refractive indices with a maximum uncertainty of ~10% (with a minimum of ~0.1%). Comparison of refractive indices calculated from measurements of a ternary solution of HNO3, H2SO4, and H2O with those published in J. Phys. Chem. A 104, 783 ( 2000) show similar differences as found by other authors.
© 2005 Optical Society of America
Full Article | PDF ArticleMore Like This
Sergey Oshchepkov, Yasuhiro Sasano, Tatsuya Yokota, Nobuyuki Uemura, Hisashi Matsuda, Yasuhiro Itou, and Hideaki Nakajima
Appl. Opt. 44(22) 4775-4784 (2005)
Carynelisa Erlick, Mitch Haspel, and Yinon Rudich
Appl. Opt. 50(22) 4393-4402 (2011)
Adam E. Heathfield, David A. Newnham, John Ballard, Roy G. Grainger, and Alyn Lambert
Appl. Opt. 38(30) 6408-6420 (1999)