Abstract
A recording transmissometer for the statistical measurements of atmospheric attenuation at 6328 Å has been set up. It measures attenuations greater than 1 dB/km, on a 90-m folded back path. The stability of its operation makes it useful in automatic continuous measurements. The instrument and the way in which the measurements are made are described, and typical results are presented.
© 1976 Optical Society of America
Full Article | PDF ArticleMore Like This
M. Galeotti, B. Daino, and D. Sette
Appl. Opt. 16(3) 660-664 (1977)
D. H. Höhn
Appl. Opt. 8(2) 367-369 (1969)
Chensheng Wu, John R. Rzasa, Jonathan Ko, Daniel A. Paulson, Joseph Coffaro, Jonathan Spychalsky, Robert F. Crabbs, and Christopher C. Davis
Appl. Opt. 57(3) 551-559 (2018)